EATON CH Series Main Lug Loadcenters


Eaton CH Series main lug loadcentres are used in industrial and commercial facilities for distributing power to various circuits and provide a central location for control & circuit protection. They receive power from the main service entrance and then distribute it to the branch circuits l...ocated throughout the area.Read more

Filter
StyleModelHeightAmpsBus MaterialNo. Of SpacesNo. Of CircuitsNo. Of WiresInterrupt RatingFeed TypePrice
A
TT120FLGNM
3 1/2"40AAluminum24310 kAIC-€46.77
B
TT120SLGNM
3 1/2"40AAluminum24310 kAIC-€46.77
C
CH6L3125FP
3 14/25"125ACopper66435 kAICTop/Bottom€156.06
D
CH6L3125SP
3 14/25"125ACopper66435 kAICTop/Bottom€156.06
E
CH6L3125RP
3 14/25"125ACopper66435 kAICOverhead€197.25
F
CH30L3150D
3 22/25"150ACopper3030435 kAICTop/Bottom€371.73
G
CH24L3225D
3 22/25"225ACopper2424435 kAICTop/Bottom€408.57
H
CH32L150D
3 22/25"150ACopper3232325 kAICTop/Bottom€243.30
I
CH24L125C
3 22/25"125ACopper2424325 kAICTop/Bottom€196.21
I
CH24L125C1N
3 22/25"125ACopper2424325 kAIC-€259.80
J
CH18L3125C
3 22/25"125ACopper1818435 kAICTop/Bottom€305.34
K
CH42L3225G
3 22/25"225ACopper4242435 kAICTop/Bottom€2,552.11
L
CH30L3225D
3 22/25"225ACopper3030435 kAICTop/Bottom€411.96
M
CH12L125RP
3 22/25"125ACopper1212325 kAIC-€251.06
N
CH12L125B
3 22/25"125ACopper1212325 kAICTop/Bottom€127.69
O
CH2L125RP
3.13"125ACopper22325 kAICOverhead€571.37
P
CH2L70FP
3.13"70ACopper22325 kAICTop/Bottom€71.66
Q
CH2L70RP
3.13"70ACopper22325 kAICOverhead€126.44
R
CH2L40RP
3.13"40ACopper22325 kAICOverhead€122.58
S
CH2L40FP
3.13"40ACopper22325 kAICTop/Bottom€54.47
T
CH2L125FP
3.13"125ACopper22325 kAICTop/Bottom€104.21
U
CH2L70SP
3.13"70ACopper22325 kAICTop/Bottom€235.82
V
CH2L125SP
3.13"125ACopper22325 kAICTop/Bottom€82.92
W
CH2L125RSE2P
3.13"125ACopper22325 kAICOverhead€147.45
X
CH4L125FP
3.69"125ACopper42325 kAICTop/Bottom€82.92
Y
CH8L125SP
3.69"125ACopper88325 kAICTop/Bottom€106.48
Y
CH8L125FP
3.69"125ACopper88325 kAICTop/Bottom€108.96
Z
CH4L125SP
3.69"125ACopper44325 kAICTop/Bottom€279.12
A1
CH4L125RP
3.69"125ACopper44325 kAICOverhead€147.83
B1
CH8L125RP
3.69"125ACopper88325 kAICOverhead€454.99
C1
CH6L125R
4 1/2"125ACopper66325 kAIC-€174.08
S
CH2L40SP
4.1"40ACopper22325 kAICTop/Bottom€45.28
G
CH24L3225R
5.19"225ACopper2424435 kAICOverhead€610.18
J
CH18L3125R
5.19"125ACopper1818435 kAICOverhead€433.76
D1
CH12L3125R
5.19"125ACopper1212435 kAICOverhead€341.19
E1
CH24L3125C
5.19"125ACopper2424435 kAICTop/Bottom€316.96
F1
CH42L3225R
5.19"225ACopper4242435 kAICOverhead€1,098.70
G1
CH24L3125R
5.19"125ACopper2424435 kAICOverhead€481.28
L
CH30L3225R
5.19"225ACopper3030435 kAICOverhead€679.00
H1
CH424PL400
6"400ACopper4242435 kAICTop/Bottom€1,433.62
H1
CH42PL400
6"400ACopper4242325 kAICTop/Bottom€1,321.67
I1
CH12L3125B
16 3/4"125ACopper1212435 kAICTop/Bottom€212.28

Features

  • Eaton CH Series main lug loadcentres feature silver flash-plated copper bus interior for durability and corrosion resistance.
  • They have cases carved with smooth edges for user safety and aesthetics.
  • They are equipped with optimised knockout for quick and easy installation or removal of the units.
  • These main lug loadcentres can accommodate copper / aluminium wires up to 14 AWG.
  • They provide a keyhole at the top and bottom facilitating easy mounting levelling.

Frequently Asked Questions

What is the difference between main circuit breaker panels and main lug loadcentres?

Main circuit breaker panels feature a main circuit breaker that acts as the main disconnect for the complete electrical system, while main lug loadcenters lack their own main circuit breaker and need manual power disconnection.

Do Eaton main lug loadcentres require professional installation?

Yes, it is recommended to have a licensed electrician to install an Eaton main lug loadcentre to ensure it is properly installed and meets local electrical codes & regulations.

We are here to help!

Looking for a part not listed here?