EATON XT IEC Series Contactors, Frame G


Eaton XT IEC Series G-frame contactors control the power to a load. They are used in industrial and commercial settings to control large motors, lighting systems and other electrical equipment.

Filter
StyleModelAmpsCoil VoltageHeightContinuous AmpsMax. HpNo. Of PolesFrequencyOperationPrice
A
CE55GN3BB
37A220-240V AC5.05"37A5 hp350-60 HzReversing€2,400.57
B
CE15GNS3AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€714.11
B
CE15GN3BB
37A220-240V AC3 3/4"37A5 hp-50-60 HzNon-Reversing€849.54
B
CE15GN2AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€824.63
B
CE15GN3CB
37A440-480V AC4.27"37A--50-60 HzNon-Reversing€849.54
B
CE15GN3AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€1,104.35
B
CE15GNS2AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing-
RFQ
C
CE15GN5AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€1,656.19
B
CE15GNS2AB-T16
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€902.11
D
CE15GN4AB
37A110-120V AC4.27"37A3 hp-50-60 HzNon-Reversing€1,313.06
B
CE15GN3TB
37A24V AC4.27"37A--60 HzNon-Reversing€849.54
D
CE15GN4BB
37A220-240V AC4.27"37A--50-60 HzNon-Reversing€1,313.06
B
CE15GNS2T4B
37A24V DC4.27"37A---Non-Reversing€1,176.06
B
CE15GNS3TB
37A24V AC4.27"37A--50-60 HzNon-Reversing€933.95
B
CE15GNS3BB
37A220-240V AC4.27"37A5 hp-50-60 HzNon-Reversing€933.95
B
CE15GNS3UB
37A24V AC4.27"37A--50 HzNon-Reversing€933.95
B
CE15GN3KB
37A240V AC4.27"37A5 hp-50 HzNon-Reversing€849.54
B
CE15GNS3EB
37A208V AC4.27"37A--60 HzNon-Reversing€933.95
B
CE15GNS3CB
37A440-480V AC4.27"37A--50-60 HzNon-Reversing€933.95
A
CE55GN3AB
37A110-120V AC5.05"37A3 hp-50-60 HzReversing€1,785.48
E
XTCE115GS1C
115A412-480/480-500V AC6 1/2"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,277.30
F
DILM115(RDC130)
115A110-130V DC170 mm115A10, 25/40, 50, 100, 100 (1/3 Phase @ 120, 240/208, 240, 480, 600V)--Reversing€1,556.56
F
DILM115-22(RAC120)
115A120V DC6.7"115A10, 25/40, 50, 100, 100 (1/3 Phase @ 120, 240/208, 240, 480, 600V)3-Non-Reversing€1,519.21
F
DILM115-22(RAC240)
115A240V DC6.7"115A10, 25/40, 50, 100, 100 (1/3 Phase @ 120, 240/208, 240, 480, 600V)3-Non-Reversing€1,519.21
E
XTCE115GS1L
115A380-440/440-3800V AC5 3/4"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,256.31
E
XTCE115G00A-LR
115A12/110-120V AC4"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,147.01
E
XTCE115GS1AD
115A120V DC6.89"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€1,607.76
E
XTCE115GS1T
115A24V AC5"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,141.47
E
XTCE115GS1A
115A110-120V AC1"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,700.73
E
XTCE115GS1TD
115A24/24-27V DC1"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€1,425.31
E
XTCE115GS2A
115A110-120V AC5"115A10, 25, 25/ 40, 50, 100, 100 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,553.81
G
XTCF125G00BD
125A220/200-240V DC6.7"125A25, 30, 60, 75 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€1,634.05
G
XTCF125G00AD
125A120V DC6.7"125A25, 30, 60, 75 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€1,634.05
G
XTCF125G00L
125A380-440/440-3800V AC6.7"125A25, 30, 60, 75 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€1,319.97
G
XTCF125G00W
125A42/42-48V AC6.7"125A25, 30, 60, 75 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€1,319.97
G
XTCF125G00WD
125A48/48-60V DC6.7"125A25, 30, 60, 75 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€1,634.05
E
XTCE150GS1TD
150A24/24-27V DC1"150A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€3,145.79
E
XTCE150GS2TD
150A24/24-27V DC1"150A-3-Non-Reversing€2,418.55
E
XTCE150GS1T
150A24V AC1"150A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€1,946.74
E
XTCE150G00AD
150A120V DC6.693"150A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing-
RFQ
E
XTCE150GS1A
150A110-120V AC1"150A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€2,362.63
G
XTCF160G00L
160A380-440/440-3800V AC6.7"160A25, 40, 75, 100 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€1,689.40
G
XTCF160G00W
160A42/42-48V AC6.7"160A25, 40, 75, 100 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€1,689.40
G
XTCF160G00WD
160A48/48-60V DC6.7"160A25, 40, 75, 100 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€2,079.57
G
XTCF160G00BD
160A220/200-240V DC6.7"160A25, 40, 75, 100 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€2,079.57
G
XTCF160G00AD
160A120V DC6.7"160A25, 40, 75, 100 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€2,079.57
E
XTCE170G00BD
170A220/200-240V DC6.89"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€2,793.50
E
XTCE170GS1TD
170A24/24-27V DC1"-10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€3,794.44
E
XTCE170G00L
170A380-440/440-3800V AC6.89"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€2,269.12
E
XTCE170G00WD
170A48-60V DC6.693"-10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€2,693.89
E
XTCE170G00AD
170A120V DC6.89"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Non-Reversing€2,793.50
E
XTCE170G00W
170A42/42-48V AC6.89"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€2,269.12
H
XTCR170G11W
170A-8 1/4"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzReversing€5,948.14
E
XTCE170GS1A
170A110-120V AC--10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)350/60 HzNon-Reversing€2,647.36
H
XTCR170G11L
170A380-440/440-3800V AC8 1/4"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)-50/60 HzReversing€5,948.14
H
XTCR170G11AD
170A120V DC8 1/4"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Reversing€6,994.15
H
XTCR170G11WD
170A-8 1/4"170A10, 25, 30/ 40, 60, 125, 125 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)3-Reversing€6,994.15
G
XTCF200G00AD
200A120V DC6.7"200A40, 50, 100, 125 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€2,468.37
G
XTCF200G00W
200A42/42-48V AC6.7"200A40, 50, 100, 125 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€2,000.71
G
XTCF200G00WD
200A48/48-60V DC-200A40, 50, 100, 125 hp (3 Phase @ 200, 230, 460, 575V)4-Non-Reversing€2,468.37
G
XTCF200G00L
200A380-440/440-3800V AC6.7"200A40, 50, 100, 125 hp (3 Phase @ 200, 230, 460, 575V)450/60 HzNon-Reversing€2,000.71

Working Mechanism

  • Contactors utilise an electromagnet to control a set of mechanical contacts.
  • The electromagnet is activated by a low-voltage electrical signal from the control circuit.
  • When the control circuit sends a signal to the electromagnet, the armature is attracted and the contacts close, allowing power to flow to the load.
  • When the control circuit stops sending the signal, the armature is released and the contacts open, breaking the flow of power to the load.

Frequently Asked Questions

How do I know when to replace a contactor?

Decrease in performance, such as frequent tripping, overheating or arcing are signs that you should replace your contactor.

Can Eaton XT IEC Series contactors be used with variable frequency drives (VFDs)?

Yes, Eaton contactors can be used with VFDs.

What is the difference between a relay and a contactor?

Relays control contacts of an electrical circuit due to a change of parameters or conditions in the same circuit or any other associated circuit. Contactors, on the other hand, are used to interrupt or establish connections in an electrical circuit repeatedly under different conditions.

What is the difference between AC and DC contactors?

DC contactor has a maximum operating frequency of 1200 times per hour, while AC contactors have a maximum operating frequency of 600 times per hour.

We are here to help!

Looking for a part not listed here?