EATON E2K Type Mining Complete Molded Case Circuit Breakers


Eaton E2K type mining complete moulded case circuit breakers prevent electrical damage to connected devices in harsh mining or industrial environments due to overloads, short circuits or ground faults. These mining circuit breakers are suitable for a wide range of monitoring and protection need...s. They are available in magnetic only or thermal-magnetic type as per your application needs.Read more

Filter
StyleModelAmpsTypeCircuit Breaker TypeVoltagePrice
A
E2K3150W
150ASpecialty CompleteE2K600V AC/250V DC€8,731.08
A
E2K3225AWU66
225A-E2K600V AC/250V DC€9,858.63
A
E2K3225WA06U66
225ASpecialty CompleteE2K600V AC/250V DC€11,293.99
A
E2K3225AW
225ASpecialty CompleteE2K600V AC/250V DC€8,590.26
A
E2K3225DWA06U66
225ASpecialty CompleteE2K600V AC/250V DC€11,322.39
A
E2K3225DWU66
225ASpecialty CompleteE2K600V AC/250V DC€10,489.31
A
E2K3250WA06U66
250ASpecialty CompleteE2K600V AC/250V DC€11,606.39
A
E2K3250WU17
250ASpecialty CompleteE2K600V AC/250V DC€10,877.43
A
E2K3300WS10
300A-E2K600V AC/250V DC€13,895.44
A
E2K3300W
300A-E2K600V AC/250V DC€8,675.93
A
E2K3350W
350ASpecialty CompleteE2K600V AC/250V DC€8,972.70
A
E2K3400MKS54
400ASpecialty CompleteE2K600V AC/250V DC€10,953.19
A
E2K3400MAW
400ASpecialty CompleteE2K600V AC/250V DC€8,590.26
A
E2K3400MGWS10
400A-E2K600V AC/250V DC€10,489.31
A
E2K3400MDWU66
400ASpecialty CompleteE2K600V AC/250V DC€10,142.39
A
E2K2400MWWT14
400ASpecialty Complete-600V AC/250V DC€9,496.98
A
E2K2400MWA06D09S10
400ASpecialty CompleteE2K600V AC/250V DC€11,341.31
A
E2K3400MWWU66
400ASpecialty CompleteE2K600V AC/250V DC€10,877.43
A
E2K3400MNWA02D11S29
400ASpecialty Complete-600V AC/250V DC€11,606.39
A
E2K3400WU66
400ASpecialty CompleteE2K600V AC/250V DC€10,877.43
A
E2K3400W
400ASpecialty CompleteE2K600V AC/250V DC€8,675.93
A
E2K3400MGWU49
400ASpecialty CompleteE2K600V AC/250V DC€10,142.39
A
E2K2400MWWS10
400ASpecialty CompleteE2K600V AC/250V DC€9,343.82
A
E2K2400MWW
400ASpecialty CompleteE2K600V AC/250V DC€6,883.66
A
E2K3400MNWA06
400ASpecialty CompleteE2K600V AC/250V DC€9,873.96
A
E2K3400WA06
400ASpecialty Complete-600V AC/250V DC-
RFQ
A
E2K3400
400A-E2K600V AC/250V DC€9,589.93
A
E2K3400MGWU66
400ASpecialty CompleteE2K600V AC/250V DC€10,489.31
A
E2K3400MWW
400ASpecialty CompleteE2K600V AC/250V DC€8,972.70
A
E2K2400MWD09
400A-E2K600V AC/250V DC€7,501.56
A
E2K3400MFWU65
400ASpecialty Frame OnlyE2K600V AC/250V DC€10,489.31
A
E2K3400MKS10
400ASpecialty CompleteE2K600V AC/250V DC€13,565.89
A
E2K3400MGWA06U66
400ASpecialty CompleteE2K600V AC/250V DC€11,170.92
A
E2K3400MJWA06T14
400ASpecialty CompleteE2K600V AC/250V DC€10,972.08
A
E2K3400MKWS10
400ASpecialty Complete-600V AC/250V DC€10,498.78
A
E2K2400MWWA06S10
400ASpecialty CompleteE2K600V AC/250V DC€9,694.08
A
E2K3400MDW
400ASpecialty CompleteE2K600V AC/250V DC€8,590.26
A
E2K3400MJWA06U66
400ASpecialty CompleteE2K600V AC/250V DC€11,625.31
A
E2K3400MNWU66
400ASpecialty CompleteE2K600V AC/250V DC€10,877.43
A
E2K3400MKWS54
400ASpecialty CompleteE2K600V AC/250V DC€10,661.27
A
E2K2400MWD09S10
400ASpecialty CompleteE2K600V AC/250V DC€9,087.87
A
E2K3400MNW
400ASpecialty CompleteE2K600V AC/250V DC€8,972.70

Working Mechanism

  • These 3-pole circuit breakers automatically interrupt the flow of electricity and protect the equipment when a fault is detected.
  • They can be reset by switching the handle to off & then on position, once the fault has been resolved.
  • Electronic trip units in these breakers can be used for monitoring & protection of the units.

Features

  • Eaton E2K type mining complete moulded case circuit breakers have a K-frame to house the trip unit & all current-carrying devices inside their frame.
  • These circuit breakers have a built-in test kit for electronic field testing and a push-to-trip button to check the tripping function during scheduled maintenance.
  • They have a sliding handle with ON & OFF positions for easy identification of the breaker's status.
  • Selected models come with line & load end caps for easy wiring connections.

Compatible Accessories

  • Shunt Trips: These devices mechanically trip the breakers remotely by applying power (from an external source) to their shunt trip terminals.
  • Auxiliary Switches: They connect to these circuit breakers to remotely indicate whether their contacts are open or closed.
  • Alarms: They indicate the tripping of the selected breaker during remote operation.

Standards and Approvals

  • CSA
  • UL

Frequently Asked Questions

What are the interrupt ratings of these Eaton E2K type mining complete moulded case circuit breakers?

  • 65kAIC at 240VAC
  • 35kAIC at 480VAC
  • 25kAIC at 600VAC
  • 10kAIC at 250VDC

What is the difference between a thermal-magnetic type and a magnetic-only circuit breaker?

The thermal-magnetic type breaker has both thermal and magnetic elements for overload trip & inrush / instantaneous trip, respectively. The magnetic-only breakers do not have thermal protection and are mainly used for motor protection.

What is the current rating of these Eaton E2K type mining complete moulded case circuit breakers?

They have a current rating ranging from 225 to 400A & a voltage rating of 600VAC or 250VDC.

We are here to help!

Looking for a part not listed here?