SQUARE D HDL26015 Circuit Breaker, 15A, 2 Poles, 600VAC, 14KA, Thermal Magnetic | AF6PQA 1MAJ5

SQUARE D HDL26015 Circuit Breaker, 15A, 2 Poles, 600VAC, 14KA, Thermal Magnetic

Item: AF6PQAModel: HDL26015Cross Ref: 1MAJ5
7 In Stock
2

Ships within 2 days via

€824.83
5.00% off
€783.59 /unit
Add To Cart
Request a Quote

Payment

Product Specifications:

Item Circuit Breaker
Ac Voltage Rating 600V AC
Actuator Toggle
Actuator Type Toggle
Ambient Air Temp. For Operation -13°F to +158°F
Ambient Air Temp. For Storage -58°F to +185°F
Amps 15A
Awg Gauge 14 AWG to 3/0 AWG
Breaking Capacity 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz, 14 kA 600V AC 50/60 Hz, 20 kA 250V DC
Breaking Capacity Code D
Circuit Breaker Actuator Toggle
Circuit Breaker Application HACR Rated
Circuit Breaker Mounting Style Free Standing
Circuit Breaker Type Standard
Color Black
Communication Interface Modbus, Ethernet
Component Type Circuit Breaker
Continuous Amps Rating 80%
Control Type Toggle
Dc Voltage 250V DC
Dc Voltage Rating 250V AC
Depth 3.4" , 4.36"
Device Application Distribution
Electrical Connection Lugs, Line, Load
Frame Size 150A/HD
Frequency 50/60 Hz
Height 6 2/5"
High Amp Trip Setting 750A
Instantaneous Trip Fixed
Ip Degree Of Protection IP40
Line Rated Amps 15A
Local Signalling Switched Off 1 Trip Indicator Green
Low Amp Trip Setting 350A
Magnetic Hold Amps 350A
Magnetic Hold Current 350A
Magnetic Tripping Amps 750A
Magnetic Tripping Current 750A
Max. Air Rating 25 kA At 240V AC
Max. Air Rating Not Rated
Max. Breaking Capacity 25 kA @ 240V AC
Max. Operating Temp. 104°F
Max. Wire Size 3 AWG
Min. Wire Size 14 AWG
Mounting Free Standing
Mounting Mode Unit Mount Lug
Mounting Style Free Standing
Mounting Support Lug
Network Frequency 50/60 Hz
No. Of Poles 2
Number Of Poles 2
Number Of Slots 5
Operating Altitude 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase 1
Pollution Degree 3 IEC 60947-1
Power Wire Stripping Length 0.6"
Product Datasheet square-d-al250jd.pdf
Quality Labels ce.png
Quantity Per Set 1
Rated Impulse Withstand Voltage 8 kV
Rated Insulation Voltage 750V
Rated Operational Voltage 690V
Rated Service Breaking Capacity 25 kA @ 220/240V AC @ 50/60 Hz, 18 kA @ 380/440/415V AC @ 50/60 Hz, 14 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability Yes
Series HD Series
Suitability For Isolation Yes, IEC 60947-2
Terminal Connection Line/Load Lug
Terminal Connection Type Line, Load Lug
Tightening Torque 44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
Trip Type Thermal Magnetic
Trip Unit Technology Thermal-Magnetic
Utilisation Category Category A
Width 2.74" , 4.09"

Shipping Info:

Ship weight (kg) 1.36
Ship height (cm)14.5
Ship length (cm)22.1
Ship width (cm)18.8
HS code8536200020
Country of OriginMX

Product Details:

Square D HDL26015 circuit breaker is a two-pole protection device that safeguards the electrical system against short circuits and overcurrents. It is useful in the construction, manufacturing, mining and energy industries.

Frequently Asked Questions:

Q. What is the difference between fixed and adjustable MCCB trip settings?

A. Fixed MCCB trip settings have predetermined overload & short-circuit protection values that cannot be changed by the user. Adjustable MCCBs allow users to customise trip settings within certain limits, providing more flexibility to match specific application requirements.

Q. What are the different pole configurations for MCCBs?

A. Square D offers MCCBs in single-pole, double-pole, three-pole and four-pole options. The pole configuration refers to the number of conductors the MCCB can interrupt simultaneously.

Q. How to ensure longevity of Square D moulded case circuit breakers?

A. Regular testing and maintenance are recommended to ensure the proper functioning of MCCBs.

Q. What is the difference between inverse time and instantaneous trip settings?

A. Inverse time trip settings in MCCBs provide a delayed response to overcurrents. The longer the overcurrent persists, the quicker the trip occurs. Instantaneous trip settings, on the other hand, result in an immediate trip response once the current exceeds a certain threshold.

Documentation:

Datasheet

Product Variants

ProductModelNumber Of PolesAmpsPhaseHigh Amp Trip SettingLow Amp Trip SettingMagnetic Hold CurrentMagnetic Tripping CurrentCircuit Breaker TypePrice
SQUARE D HDL36060 Circuit Breaker 60a 3p 600vac Lug | AF6PPZ 1MAJ4 HDL36060360A31450A800A--Standard€942.73
SQUARE D HDL26020 Circuit Breaker 20a 2p 600vac Lug | AF6PQB 1MAJ6 HDL26020220A1750A350A--Standard€824.83
SQUARE D HDL26025 Circuit Breaker 25a 2p 600vac Lug | AF6PQC 1MAJ7 HDL26025225A1750A350A--Standard€892.15
SQUARE D HDL26030 Circuit Breaker 30a 2p 600vac Lug | AF6PQD 1MAJ8 HDL26030230A1750A350A--Standard€824.83
SQUARE D HDL26040 Circuit Breaker, 40Amp, 2 Poles, 600VAC, Lug | AF6PQE 1MAJ9 HDL26040240A1850A400A--Standard€824.83
SQUARE D HDL26050 Circuit Breaker 50a 2p 600vac Lug | AF6PQF 1MAK1 HDL26050250A1850A400A--Standard€824.83
SQUARE D HDL26060 Circuit Breaker 60a 2p 600vac Lug | AF6PQG 1MAK2 HDL26060260A11450A800A--Standard€824.83

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

SQUARE D HDL26015 Circuit Breaker, 15A, 2 Poles, 600VAC, 14KA, Thermal Magnetic
€824.83 /unit