EATON HKDDC Series DC Circuit Breakers
Eaton HKDDC Series DC circuit breakers are ideal for protecting DC power distribution systems in a wide range of applications, such as data centres, renewable energy systems, telecommunication and industrial control systems.
| Style | Model | Amps | Height | Circuit Breaker Frame Type | Terminals | Under Voltage Release | Auxiliary Switch | No. Of Poles | Voltage | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | HKDDC3100WF01 | 100A | 10.13" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,615.51 | |
| A | HKDDC3150WF01 | 150A | 5 1/2" | Complete Breaker | - | - | - | 3 | - | €10,639.47 | |
| A | HKDDC3200WF01 | 200A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €18,769.72 | |
| A | HKDDC3225WF01 | 225A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,134.56 | |
| A | HKDDC3225W | 225A | 7" | Complete Breaker | - | - | - | 3 | 600V AC/250V DC | €12,618.73 | |
| B | HKDDC3250WF01 | 250A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,134.56 | |
| C | HKDDC3250W | 250A | 7" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €12,618.73 | |
| C | HKDDC3250 | 250A | 5 1/2" | Complete Breaker | - | - | - | 3 | 600V AC/250V DC | €5,767.81 | |
| C | HKDDC3300A13T1001 | 300A | 5 1/2" | Complete Breaker | Line And Load | 48-60V DC | 2A-2B Rear With Right Pigtail | 3 | 600V AC/250V DC | €11,264.09 | |
| C | HKDDC3300A13S42 | 300A | 5 1/2" | Complete Breaker | Line And Load | - | 2A-2B Rear With Right Pigtail | 3 | 600V AC/250V DC | €10,910.14 | |
| B | HKDDC3300WF01 | 300A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,134.56 | |
| B | HKDDC3350WF01 | 350A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,134.56 | |
| D | HKDDC3400KW | 400A | 12 1/4" | Molded Case Switch | Without Terminals | - | - | 3 | 600V AC/250V DC | - | RFQ
|
| C | HKDDC3400S4201 | 400A | 5 1/2" | Complete Breaker | Line And Load | - | - | 3 | 600V AC/250V DC | €10,066.87 | |
| D | HKDDC3400WF01 | 400A | 5 1/2" | Complete Breaker | Without Terminals | - | - | 3 | 600V AC/250V DC | €10,134.56 | |
| C | HKDDC3400A13T1001 | 400A | - | Complete Breaker | - | 48-60V DC | - | 3 | 600V AC/250V DC | €11,264.09 | |
| C | HKDDC3400 | 400A | 5 1/2" | Complete Breaker | - | - | - | 3 | 600V AC/250V DC | €14,075.96 | |
| D | HKDDC3400WA02T26 | 400A | 5 1/2" | Complete Breaker | Without Terminals | 24V DC | 1A-1B Rear With Left Pigtail | 3 | 600V AC/250V DC | €10,837.26 |
Features
- Eaton HKDDC Series DC circuit breakers have a K frame for resisting harsh operating conditions and long service life.
- They have current ratings ranging from 100 to 400A.
- These DC circuit breakers are equipped with a non-interchangeable thermal-magnetic trip for enhanced safety & coordination by preventing the installation of trip units with incorrect ratings.
Standards and Approvals
- UL 489
Frequently Asked Questions
How often should Eaton HKDDC Series DC circuit breakers be inspected and maintained?
To prevent safety hazards and ensure proper functioning, regular inspections and maintenance of Eaton HKDDC Series DC circuit breakers are essential. The frequency of maintenance required will vary based on the particular usage conditions and application, but it is generally advised to carry out routine inspections at least once per year.
What type of maintenance is required for Eaton HKDDC Series DC circuit breakers?
The maintenance of these DC circuit breakers includes cleaning and inspecting the breaker, replacing any worn or damaged parts and checking that the breaker still operates within its specified parameters. Depending on the particular usage, more extensive maintenance, like overhauling the breaker or swapping out the trip unit, may be needed periodically.
What should be checked during routine inspections of Eaton HKDDC Series DC circuit breakers?
- Inspect the breaker visually to detect any indications of wear or damage.
- Examine all connections thoroughly to ensure they are tight and secure.
- Confirm the trip unit's calibration and make adjustments as needed.
- Test any additional components, such as shunt trips or alarms to verify their functionality.
- Verify that the breaker can trip and cut off the circuit in case of a fault.
- Measure the insulation resistance of the breaker and search for any evidence of degradation or contamination.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- CET PUMPS
- CHAMPION TOOL STORAGE
- SHIPPERS PRODUCTS
- ASO SAFETY SOLUTIONS
- Lawn Mower Accessories
- Manual Rebar Cutters/Benders
- Concrete Chain Saw Chains and Bars
- Machine Deburring Tools
- Retaining Washers
- AKRO-MILS 30281 Akrobins Super Size Bins
- SHARPE VALVES 39306 Series, Ball Valve
- OBERON TCG Arc Flash Kits, 25 Cal Arc Rating
- CONDOR 3 Piece Rainsuit With Detachable Hood, PVC, 4 mil Thick, Yellow
- CONDOR Leather Gloves, Full Finger, Standard, Double Palm, Cowhide
- STANLEY Flat File
- APPLETON ELECTRIC 150 Watt Light Fixture
- EATON D99 Series Solid-State Relays
- APPROVED VENDOR M3 x 0.5 Headless Hex Grade 18-8 Stainless Steel Cup Socket Set Screws