EATON FD Series Complete Molded Case Circuit Breakers, F Frame
Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.
Filter
| Style | Model | Actuator Type | Type | Voltage Rating | Price | |
|---|---|---|---|---|---|---|
| A | FD2175 | - | - | - | - | RFQ
|
| B | FD3200LA02 | - | - | - | - | RFQ
|
| C | FD2070L | - | - | - | €1,354.66 | |
| C | FD2060W01V4 | - | - | - | €1,460.28 | |
| C | FD2060WF01V4 | - | - | - | €3,484.61 | |
| D | ELFD3030LA06 | - | - | - | €7,959.39 | |
| E | FD4150 | - | - | - | €4,577.49 | |
| E | FD4090L | - | - | - | €4,971.47 | |
| F | FD3225LS09 | - | - | - | €3,868.72 | |
| F | FD3225A02 | - | - | - | €8,230.82 | |
| B | FD3200VA01U21 | - | - | - | €4,387.09 | |
| B | FD3200LSD12M04 | - | - | - | - | RFQ
|
| B | FD3200LM04 | - | - | - | €3,288.18 | |
| B | FD3200LS18 | - | - | - | €4,095.64 | |
| C | FD2070B06 | - | - | - | €1,614.17 | |
| B | FD3200H08 | - | - | - | €3,602.94 | |
| B | FD3200L | - | - | - | €7,296.49 | |
| B | FD3200A10S22D01 | - | - | - | €4,911.68 | |
| B | FD3200A08 | - | - | - | €3,665.87 | |
| B | FD3200BP10 | - | - | - | €3,258.91 | |
| B | FD3175LW02 | - | - | - | €3,609.14 | |
| B | FD3175A08 | - | - | - | €3,665.87 | |
| B | FD3150VL | - | - | - | €3,145.60 | |
| B | FD3150LM04A06U14 | - | - | - | €4,441.50 | |
| B | FD3150LS06 | - | - | - | €3,967.43 | |
| B | FD3150LS02 | - | - | - | €3,967.43 | |
| B | FD3150LU05 | - | - | - | - | RFQ
|
| C | FD2070V | - | - | - | €1,275.33 | |
| C | FD2080L | - | - | - | €1,341.25 | |
| B | FD3150LM04 | - | - | - | €3,288.18 | |
| C | FD2150 | - | - | - | €1,577.42 | |
| C | FD2200WS18 | - | - | - | €3,659.66 | |
| C | FD2200WS21 | - | - | - | €3,799.32 | |
| C | FD2225D22M03 | - | - | - | €2,862.29 | |
| C | FD2200H08 | - | - | - | €2,879.41 | |
| C | FD2200L | - | - | - | €3,028.91 | |
| C | FD2200LSD12M03 | - | - | - | €6,697.04 | |
| C | FD2175VL | - | - | - | €2,870.07 | |
| C | FD2200LSB06D12MO3 | - | - | - | €3,280.40 | |
| C | FD2175LS21 | - | - | - | €3,682.99 | |
| C | FD2150L | - | - | - | €2,955.85 | |
| C | FD2150LF01V4 | - | - | - | €3,990.73 | |
| C | FD2175L | - | - | - | €2,870.07 | |
| C | FD2125LSA06 | - | - | - | €3,123.42 | |
| C | FD2090L | - | - | - | €1,354.66 | |
| C | FD2125 | - | - | - | €1,577.42 | |
| C | FD2125L | - | - | - | €5,443.17 | |
| C | FD2125A06 | - | - | - | €3,236.11 | |
| C | FD2125V | - | - | - | €2,852.19 | |
| C | FD2100S22 | - | - | - | €2,031.49 | |
| C | FD2110L | - | - | - | €2,755.03 | |
| C | FD2110 | - | - | - | €1,577.42 | |
| C | FD2100LD12M03 | - | - | - | €1,319.63 | |
| C | FD2100LB06D12M03 | - | - | - | €1,710.53 | |
| C | FD2100L | - | - | - | €2,109.05 | |
| C | FD2100B06 | - | - | - | €1,676.34 | |
| C | FD2100C05 | - | - | - | €1,907.94 | |
| B | FD3150LS09 | - | - | - | €8,907.87 | |
| E | FD4150A14S08 | - | - | - | €13,462.10 | |
| C | FD2200WA05 | - | - | - | €3,241.56 | |
| B | FD3150A02 | - | - | - | €3,672.10 |
Working Mechanism
- Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
- The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
- The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
- As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
- This opens the contact again and stops the current flow, preventing any further damage to the equipment.
Features
- These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
- They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
- These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
- They are integrated with load-side terminals for easy installation with panelboards and load centres.
Standards and Approvals
- UL
Frequently Asked Questions
How to maintain the frame of these molded case circuit breakers?
- Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
- Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
- Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.
What is the function of molded cases?
Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- PEX Fittings
- Faceshield Assemblies
- Cutting and Grinding Fluids
- Sequencers
- Magnifier Measuring Scales
- AKRO-MILS 30283 Akrobins Super Size Bins
- OIL SAFE ID Tabs
- MEMPHIS GLOVE Luminator Drivers Insulated Work Gloves
- JOHN GUEST Fixed Elbows, NPTF Thread, Acetal White
- ANVIL 2143 Series Caps, Forged Steel, Threaded
- HAMILTON Swivel Plate Caster w/4-Position Directional Lock, Forged Steel
- THOMAS & BETTS Bushed Elbows
- PALMETTO PACKING 1367 Style H Packing Seals
- NIBCO TPC-585-70-66 Series Ball Valves, Bronze, 250 PSI, Full Port, Thread x Press Ends, Stainless Steel Trim
- QUANTUM STORAGE SYSTEMS Interlocking Storage Cabinet Drawers





