EATON Bussmann Series HLE Fuses


Eaton Bussmann Series HLE fuses are high-speed, current-limiting fuses that protect power electronics equipment, including inverters, drives and rectifiers. These fuses are designed to prevent short circuits & overloads.

Filter
StyleModelAmpsVoltageInterrupt RatingHeightNotesFuse ClassPrice
A
15HLE-CL
-14.4 kV63 Kaic0.001"Consult Factory For Mountings.-€6,177.12
B
8HLE-40E
-7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,605.32
C
8HLE-CL
-7.2 kV50 Kaic0.001"Consult Factory For Mountings.Class E€4,354.93
C
5HLE-10E
10A-63 Kaic0.001"Consult Factory For Mountings.-€2,406.67
D
15HLE-10E
10A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,407.54
C
5HLE-15E
15A-63 Kaic0.001"Consult Factory For Mountings.-€2,406.67
B
8HLE-20E
20A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
C
5HLE-20E
20A-63 Kaic0.001"Consult Factory For Mountings.-€2,406.67
A
15HLE-20E
20A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,430.47
A
15HLE-25E
25A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,430.47
B
8HLE-25E
25A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
C
5HLE-25E
25A-63 Kaic0.001"Consult Factory For Mountings.-€2,406.67
A
15HLE-30E
30A14.4 kV65 Kaic-Consult Factory For Mountings.Class E-
RFQ
B
8HLE-30E
30A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
C
5HLE-30E
30A-63 Kaic0.001"Consult Factory For Mountings.-€2,406.67
A
15HLE-40E
40A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,407.54
E
5HLE-40E
40A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,406.67
A
15HLE-50E
50A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,407.54
B
8HLE-50E
50A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
E
5HLE-50E
50A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,406.67
A
15HLE-65E
65A-65 Kaic3"Consult Factory For Mountings.-€3,407.54
E
5HLE-65E
65A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,406.67
E
5HLE-80E
80A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,406.67
B
8HLE-80E
80A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
A
15HLE-80E
80A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€3,407.54
B
8HLE-100E
100A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€2,895.65
E
5HLE-100E
100A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,406.67
E
5HLE-125E
125A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€4,576.49
A
15HLE-125E
125A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€6,486.56
B
8HLE-125E
125A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€5,458.94
E
5HLE-150E
150A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€2,489.15
B
8HLE-150E
150A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€5,458.94
A
15HLE-150E
150A-65 Kaic3"Consult Factory For Mountings.-€6,486.56
B
8HLE-175E
175A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€5,458.94
C
5HLE-175E
175A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€3,077.78
A
15HLE-175E
175A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€6,486.56
E
5HLE-200E
200A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€4,576.49
F
8HLE-200E
200A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€9,053.69
A
15HLE-200E
200A-65 Kaic3"Consult Factory For Mountings.-€6,486.56
F
8HLE-250E
250A7.2 kV50 Kaic3"Consult Factory For Mountings.Class E€9,053.69
A
15HLE-250E
250A14.4 kV65 Kaic3"Consult Factory For Mountings.Class E€6,169.06
E
5HLE-250E
250A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€4,576.49
E
5HLE-300E
300A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€7,548.55
E
5HLE-350E
350A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€4,105.69
E
5HLE-400E
400A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€7,964.95
E
5HLE-450E
450A4.8 kV63 Kaic0.001"Consult Factory For Mountings.Class E€7,964.95

Working Mechanism

  • When the current flowing through the circuit exceeds a certain level, the fuse element melts and interrupts the circuit.
  • This interruption prevents the current flow to the equipment and stops the flow of electricity.
  • The high-speed action of the fuse ensures that the interruption occurs quickly, reducing the risk of equipment damage or failure.
  • As a result, the equipment is protected from potential damage due to excessive current flow.

Features

  • They feature a single barrel design for reduced weight and enhanced performance.
  • These fuses can be operated in both indoor / outdoor environments.
  • They have an interrupt rating of 65kAIC for safe operations at rated voltage.

Standards and Approvals

  • IEEE

Frequently Asked Questions

What are the factors to consider while installing Eaton Bussmann Series HLE fuses?

  • Ensure that fuses are properly sized and rated for the specific application.
  • The installation should be carried out by the manufacturer's instructions and safety regulations.

How do I maintain these HLE fuses?

  • Regularly inspect Eaton Bussmann Series HLE fuses to ensure they are in good condition and functioning correctly.
  • Replace damaged or defective fuses immediately with new fuses of the same type and rating.
  • Store fuses in a cool & dry place to prevent exposure to moisture, dust and other contaminants.
  • Use proper tools, such as fuse pullers while installing or removing fuses.
  • Maintain a record of installation, inspection and replacement of fuses.

What is the difference between a fuse and a circuit breaker?

fuse is a small, replaceable device consisting a metal wire or filament that melts when it's overloaded, thus interrupting the electrical circuit. A circuit breaker, on the other hand, is an automatic device that uses a switch mechanism to interrupt the flow of current in the event of an overload or short circuit.

We are here to help!

Looking for a part not listed here?