StyleModelItemPrice (ex. VAT)
AVZ18Extension Kit€75.42
AVZ31Extension Kit€72.20
BGV3P25Manual Motor Switch€780.40
CGV2K031Manual Motor Switch€82.56
DGV2ME103Manual Motor Switch€287.77
EGP2E16Manual Motor Switch€108.99
FGP2E22Manual Motor Switch€129.65
GGP2E32Manual Motor Switch€154.49
HGP2E08Manual Motor Switch€100.50
IGP2E10Manual Motor Switch€100.37
JGP2E03Manual Motor Switch€101.39
CGV2K04Manual Motor Switch€229.14
KGV2G245Manual Motor Switch€37.68
DGV2G254Manual Motor Switch€37.85
LGV2G345Manual Motor Switch€51.00
MGV2G354Manual Motor Switch€50.10
DGV1G02Manual Motor Switch€26.21
NGV1L3Manual Motor Switch€228.77
OGV2MP03Manual Motor Switch€55.64
PGV2V01Manual Motor Switch€53.63
QGV2V03Manual Motor Switch€56.12
OGV2MP01Manual Motor Switch€49.89
DGVAS116Manual Motor Switch€134.62
RGP2E21Manual Motor Switch€105.47
SGV2GH7Manual Motor Switch€23.91
SCHNEIDER ELECTRIC -

Manual Motor Starters

StyleModelHP @ 3 Phase - 575VAmps ACDepthOverload Relay Amp SettingPilot LightWidthHeightHP @ 1 Phase - 120VPrice (ex. VAT)
AGV2P03-15 to 253.83"0.25 to 0.4ANo1.75"3.5"-€316.69
BGV2ME01-48 to 653.03"0.1 to 0.16AYes1.75"3.5"-€99.88
AGV2P01--3.83"0.1 to 0.16ANo1.75"3.5"-€314.90
AGV2P02--3.83"0.16 to 0.25ANo1.75"3.5"-€319.75
BGV2ME02-60 to 1003.03"0.16 to 0.25ANo1.75"3.5"-€99.88
BGV2ME04-0.40 to 0.632.6"0.4 to 0.63ANo1.75"3.5"-€99.88
AGV2P04--3.83"0.4 to 0.63AYes1.75"3.5"-€357.20
CGV2ME03-0.25 to 0.402.6"0.25 to 0.4AYes1.75"3.5"-€99.88
AGV2P061-3.83"1 to 1.6AYes1.75"3.5"-€378.55
BGV2ME0611 to 1.62.6"1 to 1.6ANo1.75"3.5"-€99.88
AGV2P071.5-3.83"1.6 to 2.5AYes1.75"3.5"-€349.97
BGV2ME071.51.6 to 2.52.6"1.6 to 2.5AYes1.75"3.5"-€316.82
BGV2ME051/20.63 to 1.002.6"0.63 to 1AYes1.75"3.5"-€275.30
AGV2P051/2-3.83"0.63 to 1ANo1.75"3.5"-€396.66
AGV2P083-3.83"2.5 to 4AYes1.75"3.5"1/8€371.82
BGV2ME0832.5 to 42.6"2.5 to 4ANo1.75"3.5"1/8€99.88
BGV2ME1054 to 6.32.6"4 to 6.3ANo1.75"3.5"1/4€99.88
AGV2P105-3.83"4 to 6.3AYes1.75"3.5"1/4€346.41
BGV2ME147.56 to 102.6"6 to 10ANo1.75"3.5"1/2€104.78
AGV2P147.5-3.83"6 to 10AYes1.75"3.5"1/2€417.97
DGV3P13109 to 134.4"9 to 13ANo2.4"4.7"1€276.63
BGV2ME201013 to 182.6"13 to 18ANo1.75"3.5"1€104.78
BGV2ME16109 to 142.6"9 to 14ANo1.75"3.5"3/4€104.78
AGV2P1610-3.83"9 to 14AYes1.75"3.5"3/4€483.77
AGV2P2015-3.83"13 to 18AYes1.75"3.5"1€445.83

Features

  • Schneider manual motor starters prevent the motor from drawing a large amount of starting current.
  • They ensure smooth starting by controlling torque for slow acceleration, thereby reducing jerks.
  • These starters avoid short-circuit and overload problems.
  • They shut down the motor automatically when the power source is turned off.

Working Mechanism

  • Schneider motor starters comprise two devices: a contractor and an overload relay.
  • The contractor completes the circuit to the motor, and the overload relay keeps track of how much current the motor is using.
  • Their overload protection mechanism regulates the maximum load the motor may safely bear.
  • When the motor exceeds its maximum capacity, these starters open the motor starting control circuit and turn the motor off.

Standards and Approvals

  • UL
  • CSA
  • CE

Frequently Asked Questions

What is the difference between a manual motor starter and an automatic motor starter?

A manual motor starter requires manual intervention to start and stop the motor, while an automatic motor starter can automatically start and stop the motor based on preset conditions or control signals.

Can I automate Schneider manual motor starters?

Yes, you can integrate these motor starters with programmable logic controllers (PLCs) or other control devices for automated operation and remote monitoring.

What is the difference between a motor starter and a motor contactor?

A motor starter includes a motor contactor as one of its components. The motor contactor is responsible for opening and closing the electrical circuit to start or stop the motor, while the starter also includes overload protection and control components.