Product Specifications:

Item Circuit Breaker
Accessory/separate Part Type Shunt Trip 110-130V AC Compartment
Ambient Air Temp. For Operation -13°F to +158°F
Ambient Air Temp. For Storage -58°F to +185°F
Amps 80A
Awg Gauge 14 AWG to 3/0 AWG
Breaking Capacity 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz, 14 kA 600V AC 50/60 Hz, 20 kA 250V DC
Breaking Capacity Code D
Circuit Breaker Application HACR Rated
Color Black
Communication Interface Modbus, Ethernet
Component Type Circuit Breaker
Continuous Amps Rating 80%
Control Type Toggle
Depth 3.4"
Device Application Distribution
Electrical Connection Lugs, Line, Load
Frame Type HDL
Height 6 2/5"
Ip Degree Of Protection IP40
Line Rated Amps 80A
Local Signalling Switched Off 1 Trip Indicator Green
Magnetic Hold Amps 800A
Magnetic Tripping Amps 1450A
Mounting Mode Unit Mount Lug
Mounting Support Lug
Network Frequency 50/60 Hz
No. Of Poles 3
Number Of Poles 3
Number Of Slots 5
Operating Altitude 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Pollution Degree 3 IEC 60947-1
Power Wire Stripping Length 0.6"
Quality Labels ce.png
Quantity Per Set 1
Rated Impulse Withstand Voltage 8 kV
Rated Insulation Voltage 750V
Rated Operational Voltage 690V
Rated Service Breaking Capacity 25 kA @ 220/240V AC @ 50/60 Hz, 18 kA @ 380/440/415V AC @ 50/60 Hz, 14 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability Yes
Suitability For Isolation Yes, IEC 60947-2
Tightening Torque 44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
Trip Unit Technology Thermal-Magnetic
Utilisation Category Category A
Voltage 600V
Voltage Type AC
Width 4.09"

Shipping Info:

Ship weight (kg) 1.89
Ship height (cm)16.26
Ship length (cm)11.07
Ship width (cm)10.46
Country of OriginUS

Product Details:

    • Square D HDL36080SA circuit breaker used for protection against abnormal or faulty currents causing electrical damage
    • Features thermal magnetic trip unit with both instantaneous and time delayed functionality providing current limiting protection
    • Includes 120VAC shunt trip for remote opening of contacts protecting the solenoid (armature) from excessive current surge
    • Unit mount design with load & line lugs for ease of installation and hassle free wiring
    • Accommodates wires (copper / aluminium) of sizes ranging from 14 to 3/0 AWG
    • UL-listed and CSA-certified

Product Variants

ProductModelNumber Of PolesAmpsPhaseHigh Amp Trip SettingLow Amp Trip SettingMagnetic Hold CurrentMagnetic Tripping CurrentCircuit Breaker TypePrice
SQUARE D HDL36060 Circuit Breaker 60a 3p 600vac Lug | AF6PPZ 1MAJ4 HDL36060360A31450A800A--Standard€942.73
SQUARE D HDL26015 Circuit Breaker, 15A, 2 Poles, 600VAC, 14KA, Thermal Magnetic | AF6PQA 1MAJ5 HDL26015215A1750A350A350A750AStandard€824.83
SQUARE D HDL26020 Circuit Breaker 20a 2p 600vac Lug | AF6PQB 1MAJ6 HDL26020220A1750A350A--Standard€824.83
SQUARE D HDL26025 Circuit Breaker 25a 2p 600vac Lug | AF6PQC 1MAJ7 HDL26025225A1750A350A--Standard€892.15
SQUARE D HDL26030 Circuit Breaker 30a 2p 600vac Lug | AF6PQD 1MAJ8 HDL26030230A1750A350A--Standard€824.83
SQUARE D HDL26040 Circuit Breaker, 40Amp, 2 Poles, 600VAC, Lug | AF6PQE 1MAJ9 HDL26040240A1850A400A--Standard€824.83
SQUARE D HDL26050 Circuit Breaker 50a 2p 600vac Lug | AF6PQF 1MAK1 HDL26050250A1850A400A--Standard€824.83

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

SQUARE D HDL36080SA PowerPact H Circuit Breaker, 80A, 3P, Shunt Trip, Unit Mount
€1,196.43 /unit