Product Specifications:

Item Circuit Breaker
Ac Voltage Rating 525V AC
Actuator Type Toggle
Ambient Air Temp. For Operation -13°F to +158°F
Ambient Air Temp. For Storage -58°F to +185°F
Amps 80A
Awg Gauge 14 AWG to 2/0 AWG
Breaking Capacity 25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489
Breaking Capacity Code D
Circuit Breaker Actuator Toggle
Circuit Breaker Application HACR Rated
Circuit Breaker Mounting Style I-Line
Circuit Breaker Type Standard
Color Gray
Component Type Circuit Breaker
Connection Pitch 1.06"
Continuous Amps 80%
Control Type Toggle
Dc Voltage Not Rated
Depth 3 1/2"
Device Application Distribution
Electrical Connection I-Line Connection, Line, Lugs, Load
Electrical Durability 10000 Cycles
For Use With Electrical Distribution Equipment, Industrial Control Panels
Frame 125A/BD
Frame Type BDA
Height 5 2/5" , 5.39"
Ik Degree Of Protection IK07
Instantaneous Trip Fixed
Ip Degree Of Protection IP40
Line Rated Amps 80A
Local Signalling Presence Of Auxiliary Contacts Flag Green
Max. Air Rating 25 kA At 277/408V AC
Max. Air Rating 25kA at 277/408V AC
Max. Operating Temp. 158°F
Max. Operating Temp. 158 Deg. F
Max. Wire Size 2 AWG
Mechanical Durability 20000 Cycles
Min. Operating Temp. -13°F
Min. Wire Size 14 AWG
Mounting Height 4.5"
Mounting Mode I Line
Mounting Style Inline
Network Frequency 50/60 Hz
No. Of 9 Mm Pitches 9
No. Of Poles 3
No. Of Slots 3
Operating Altitude 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase 3
Phase Connection ABC
Pollution Degree 3 IEC 60947-1
Power Wire Stripping Length 0.8"
Quality Labels ce.png
Quantity Per Set Set of 1
Rated Impulse Withstand Voltage 8 kV
Rated Insulation Voltage 800V
Rated Operational Voltage 525V
Rated Service Breaking Capacity 25 kA @ 220-240V AC @ 50/60 Hz, 14 kA @ 500-525V AC @ 50/60 Hz, 18 kA @ 380-415V AC @ 50/60 Hz, 18 kA @ 440V AC @ 50/60 Hz
Returnability Yes
Suitability For Isolation Yes, IEC 60947-2
Terminal Connection Al Mechanical Lug Off End, I-Line On End
Tightening Torque 31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG
Trip Type Thermal Magnetic
Trip Unit Technology Thermal-Magnetic
Utilisation Category Category A
Voltage 600V
Voltage Type AC
Width 3.19" , 3.2"

Shipping Info:

Ship weight (kg) 0.79
Ship height (cm)13.69
Ship length (cm)8.89
Ship width (cm)8.1
Country of OriginMX

Product Details:

    • Square D BDA36080 Powerpact BDA Series circuit breaker designed to prevent short-circuit and overload conditions in panelboards and switchboards
    • Features a thermal-magnetic trip which provides both instantaneous and time-delayed current limiting functions
    • I-Line plug-in and load-side lug terminals to reduce the installation downtime
    • Meets CSA, IEC and NEMA standards

Product Variants

ProductModelHeightNo. Of PolesAmpsDepthPhase ConnectionLine Rated AmpsRated Operational VoltageBreaking CapacityPrice
SQUARE D BDA34125Y Circuit Breaker, 125A, I-Line Style, 25kA @ 277 / 480V | CE6GQA BDA34125Y5.39"3125A3.5"ABC125A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€1,111.01
SQUARE D BDA261002 Circuit Breaker, 2-Pole, 100A, Toggle, Fixed Trip, 1-Phase | CE6GQB BDA2610025.39"2100A3.5"AC100A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€895.03
SQUARE D BDA261001 Molded Case Circuit Breaker, 2-Pole, Thermal-Magnetic Trip | CE6GQC BDA2610015 2/5"2100A3 1/2"AB100A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€895.03
SQUARE D BDA260802 Type BDA Circuit Breaker, 1-Phase, 80A, 2-Pole, I-Line Mount | CE6GQD BDA2608025 2/5"280A3 1/2"AC80A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€895.03
SQUARE D BDA34015Y Type BDA Circuit Breaker, 15 A, 3 Pole, Thermal Magnetic Trip | CE6GQE BDA34015Y5.39"315A3.5"ABC15A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€972.16
SQUARE D BDA34090Y Type BDA Circuit Breaker, 90 A, 3 Pole, Thermal Magnetic Trip | CE6GQF BDA34090Y5 2/5"390A3 1/2"ABC90A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€1,111.01
SQUARE D BDA34070Y Type BDA Circuit Breaker, 70 A, 2 Pole, Thermal Magnetic Trip | CE6GQG BDA34070Y5.39"370A3.5"ABC70A525V25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489€1,111.01

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

SQUARE D BDA36080 Molded Case Circuit Breaker, 80A, Number Of Poles 3, Series Bda
€1,080.16 /unit