| Item | Circuit Breaker |
| Ac Voltage Rating | 525V AC |
| Ambient Air Temp. For Operation | -13°F to +158°F |
| Ambient Air Temp. For Storage | -58°F to +185°F |
| Amps | 70A |
| Awg Gauge | 14 AWG to 2/0 AWG |
| Breaking Capacity | 25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489 |
| Breaking Capacity Code | D |
| Circuit Breaker Actuator | Toggle |
| Circuit Breaker Application | HACR Rated |
| Circuit Breaker Mounting Style | I-Line |
| Circuit Breaker Type | Standard |
| Color | Gray |
| Component Type | Circuit Breaker |
| Connection Pitch | 1.06" |
| Continuous Amps Rating | 80% |
| Control Type | Toggle |
| Dc Voltage Rating | Not Rated |
| Depth | 3.5" |
| Device Application | Distribution |
| Electrical Connection | I-Line Connection, Line, Lugs, Load |
| Electrical Durability | 10000 Cycles |
| For Use With | Electrical Distribution Equipment, Industrial Control Panels |
| Frame Size | 125A, BD |
| Frame Type | BDA |
| Height | 5.39" |
| Ik Degree Of Protection | IK07 |
| Instantaneous Trip | Fixed |
| Ip Degree Of Protection | IP40 |
| Line Rated Amps | 70A |
| Local Signalling | Presence Of Auxiliary Contacts Flag Green |
| Max. Air Rating | 25 kA At 277/408V AC |
| Max. Operating Temp. | 158°F |
| Max. Wire Size | 2 AWG |
| Mechanical Durability | 20000 Cycles |
| Min. Operating Temp. | -13°F |
| Min. Wire Size | 14 AWG |
| Mounting Height | 4.5" |
| Mounting Mode | I Line |
| Network Frequency | 50/60 Hz |
| No. Of 9 Mm Pitches | 9 |
| No. Of Poles | 3 |
| Number Of Poles | 3 |
| Number Of Slots | 3 |
| Operating Altitude | 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating |
| Phase | Three |
| Phase Connection | ABC |
| Pollution Degree | 3 IEC 60947-1 |
| Power Wire Stripping Length | 0.8" |
| Quality Labels | ce.png |
| Quantity Per Set | Set of 1 |
| Rated Impulse Withstand Voltage | 8 kV |
| Rated Insulation Voltage | 800V |
| Rated Operational Voltage | 525V |
| Rated Service Breaking Capacity | 25 kA @ 220-240V AC @ 50/60 Hz, 14 kA @ 500-525V AC @ 50/60 Hz, 18 kA @ 380-415V AC @ 50/60 Hz, 18 kA @ 440V AC @ 50/60 Hz |
| Returnability | Yes |
| Suitability For Isolation | Yes, IEC 60947-2 |
| Terminal Connection | Al Mechanical Lug Off End, I-Line On End |
| Tightening Torque | 31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG |
| Trip Type | Thermal Magnetic |
| Trip Unit Technology | Thermal-Magnetic |
| Utilisation Category | Category A |
| Voltage | 600V |
| Voltage Type | AC |
| Width | 3.19" |
Shipping Info:
| Ship weight (kg) | 1.69 |
| Ship height (cm) | 13.69 |
| Ship length (cm) | 8.89 |
| Ship width (cm) | 8.1 |
| Country of Origin | MX |
Product Details:
- Square D BDA34070Y Powerpact BDA Series circuit breaker designed for protecting wires from overheating & fault currents
- Thermal magnetic trip for both instantaneous and long-time current limiting protection
- 2 pole unit with 70 A current flow and breaking capacity of 18 kAIC @ 277 VAC for maximum protection
- Comes equipped with I-Line plug-in and load side lug terminals for easy installation and repairs
- Accommodates aluminium and copper wires of sizes ranging from 14 to 2 AWG
- UL, CSA and IEC listed
Product Variants
| Model | Number Of Poles | Phase Connection | Amps | Ac Voltage Rating | Phase | Frame Size | Mounting Height | Circuit Breaker Mounting Style | Price | |
|---|---|---|---|---|---|---|---|---|---|---|
| BDA34125Y | 3 | ABC | 125A | 277/480V AC | Three | 125A, BD | 4.5" | I-Line | €1,212.01 | |
| BDA261002 | 2 | AC | 100A | 525V AC | Single | 125A, BD | 3" | I-Line | €976.39 | |
| BDA261001 | 2 | AB | 100A | - | - | - | 3" | - | €976.39 | |
| BDA260802 | 2 | AC | 80A | - | - | - | 3" | - | €976.39 | |
| BDA34015Y | 3 | ABC | 15A | 525V AC | Three | 125A, BD | 4.5" | I-Line | €1,060.54 | |
| BDA34090Y | 3 | ABC | 90A | - | - | - | 4.5" | - | €1,212.01 | |
| BDA34050Y | 3 | ABC | 50A | 525V AC | 3 | - | 4.5" | I-Line | €1,060.54 |
Explore Products
- EATON 10250T197LAG2A Pushbutton, Heavy-Duty, Standard Actuator, Led, Full Voltage, Amber, Glass, 120 V
- RON CRANE SCALES RON2501S40 Dynamometer, 80000 Lbs Capacity, Wireless, 28 lb
- OSG 595523411 Jobber Length Drill Bit, 15/64 Inch Size, 92 mm Overall Length
- DIXON CS200-12CS Crimp Sleeve, Carbon Steel, 3 Inch I.D., 2-57/64 to 2-60/64 Inch O.D.
- CONTRINEX YXC-2040-F00 Protective Column, 2020mm Housing
- MAIN FILTER INC. MF0308461 HF6586 Interchange Spin-On Filter, Glass, 5 Micron Rating, Buna Seal, 11.657 Inch Height
- METRO 74PS-4 2448NS-4 Wire Shelving Unit, Starter, 48 Inch x 24 Inch, 74 Inch Overall Height, 4 Shelves
- AIRMASTER FAN 31109 PACA23.75-18V Roof Curb, Height 8 Inch
Explore More
- KEYSHAFT
- TURTLESKIN
- CLE-FORCE
- MAXLITE
- TUFFTRAK SAFETY
- Abrasive Cut-Off and Chop Wheels
- LED Parking Garage Fixtures
- Thermocouple Thermometers
- Control Keys
- Gearmotor Accessories
- DAYMARK 921 Steam Resistant Gloves
- CHICAGO PROTECTIVE APPAREL CarbonX Fire Resistant Long Sleeve UnderShirts
- MEMPHIS GLOVE Cut Pro Kevlar/Steel Shell Cut Resistant Work Gloves, 13 Gauge
- CONDOR Coated Gloves, Smooth, Polyurethane, Palm Dipped, Black
- ANVIL AS200KO Series Channels With Knock Out
- VESTIL Rounded Dome Bumpers
- IGUS 07 Series, Cable Carrier Open
- LEESON Premium Duck Washguard Motors, Three Phase, TENV/TEFC, C Face Less Base
- WERMA Conduits
- JOMAR VALVE High Performance Butterfly Valves, Stainless Steel Body, ANSI Class 150, RPTFE Seat, Gear Operator
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
SQUARE D BDA34070Y Type BDA Circuit Breaker, 70 A, 2 Pole, Thermal Magnetic Trip
€1,212.01 /unit