FREE delivery on orders over €150
Product Specifications:
| Item | Thermocouple Thermometer |
| Accuracy | -327°F to +999.9°F, +/-(0.4% + 1.8°F), 1000°F to 1562°F, +/-(0.4% + 2°F), -199.9°C to +850°C, +/-(0.4% + 1°C) , 32°F to 3092°F, +/-(0.5% + 5°F), 0°C to 1700°C, +/-(0.5% + 3°C) , ±0.4% +1.8°F, 1°C |
| Accuracy Type E | -148°F to -58.1°F, +/-(0.4% + 1.8°F), -58°F to +999.9°F, +/-(0.4% + 1°F), 1000°F to 1652°F, +/-(0.4% + 2°F), -100°C to -50.1°C, +/-(0.4% + 1°C), -50°C to +900°C, +/-(0.4% + 0.5°C) |
| Accuracy Type J | -148°F to -58.1°F, ±(0.4% + 1.8°F), -58°F to 999.9°F, ±(0.4% + 1°F), 1000°F to 2102°F, ±(0.4% + 2°F), -100°C to -50.1°C, ±(0.4% + 1°C), -50°C to 999.9°C, ±(0.4% + 0.5°C), 1000°C to 1150°C, ±(0.4% + 1°C) |
| Accuracy Type K | -148°F to -58.1°F, +/-(0.4% + 1.8°F), -58°F to 999.9°F, +/-(0.4% + 1°F), 1000°F to 2372°F, +/-(0.4% + 2°F), -100°C to -50.1°C, +/-(0.4% + 1°C), -50°C to 999.9°C, +/-(0.4% + 0.5°C), 1000°C to 1300°C, +/-(0.4% + 1°C) |
| Accuracy Type S | 32°F to 2732°F, +/-(0.5% + 5°F), 0°C to 1500°C, +/-(0.5% + 3°C) |
| Accuracy Type T | -148°F to -58.1°F, ±(0.4% + 1.8°F), -58°F to 752.0°F, ±(0.4% + 1°F), -100°C to -50.1°C, ±(0.4% + 1°C), -50°C to 400.0°C, ±(0.4% + 0.5°C) |
| Auto Power Off | Yes |
| Backlit | Yes |
| Calibration Certificate | No |
| Calibration Certificate Included | No |
| Data Hold | Yes |
| Data Logging | Yes |
| Data Output | Yes Rs 232 |
| Data Output Type | RS 232 |
| Data Storage | Yes |
| Differential Measurement (t1-t2) | Yes |
| Digit Height | 20 mm |
| Digital Display | 38 mm H x 53 mm W Display With 3.5 Digit Backlit LCD 20 mm Digit Height |
| Dimensions | 7" x 2.7" x 1.8" |
| Display Height | 38mm |
| Display Height | 38 mm |
| Display Size | 38mm x 53mm |
| Display Size | 38 mm x 53 mm |
| Display Type | Quad Display, Lcd |
| Display Width | 53mm |
| Display Width | 53 mm |
| External Memory | Yes, Expandable Up to 16 GB With SD Card |
| For Rtd Type | PT 100 |
| For Thermocouple Type | Type E, Type J, Type K, Type R, Type S, Type T |
| Functions | °F/°C Switchable, 2-Channel Rtd Temperature Measurement, 4-Channel Thermocouple Temperature Measurement, Data Hold, Date/Time Stamp, Low Battery Indication, Maximum And Minimum Indicators, Thermocouple Input Type |
| Height | 20 mm |
| Humidity Range | 10% to 85% |
| Included Probes | Mini-Type |
| Includes | Batteries |
| Includes Batteries | Yes |
| Includes Nist-traceable Certificate | No |
| Includes Wireless Transmission | No |
| Kick Stand | Yes |
| Low Battery Indicator | Yes |
| Manufacturer Warranty Length | 1 yr. |
| Max. Function | Yes |
| Measurement Range Rtd Pt100 Ohm | -327.9°F to +1562°F |
| Measurement Range Type E | -148°F to +1652°F |
| Measurement Range Type J | -148°F to +2102°F |
| Measurement Range Type K | -148°F To +2372°F |
| Measurement Range Type R | 32°F to +3092°F |
| Measurement Range Type S | 32°F to 2732°F |
| Measurement Range Type T | -148°F to +752°F |
| Memory | Min/Max |
| Min. Function | Yes |
| No. Of Batteries | 6 |
| No. Of Batteries Required | 6 |
| Number Of Channels | 4 |
| Number Of Digits | 3.5 |
| Number Of Inputs | 4 |
| Operating Humidity | Less Than 85% Rh |
| Operating Temp. | 32°F to 122°F |
| Power Source Details | (6) AA Batteries |
| Real-time Clock And Date Stamp | Yes |
| Resistance | 100 ohms |
| Resolution | 0.1°F, 0.1°C, 1°F, 1°C |
| Resolution Rtd Pt100 Ohm | 0.1°F, 1°F >= 1000° |
| Resolution Type E | 0.1°F, 1°F >= 1000° |
| Resolution Type J | 0.1°F, 1°F >= 1000° |
| Resolution Type K | 0.1°F, 1°F >= 1000° |
| Resolution Type R | 1°F |
| Resolution Type S | 1°F |
| Resolution Type T | 0.1°F |
| Response Time | 1x per sec. |
| Rtd Resistance | 100 ohms |
| Rtd Temperature Range °c | -199.9°C to +850°C |
| Rtd Temperature Range °f | -327.9°F to +1562°F |
| Sampling Rate | 1 sec. to 3600 sec. |
| Sd Card Class Compatibility | Class 4 |
| Selectable Sampling Rate | Yes, 1 sec., 2 sec., 5 sec., 10 sec., 30 sec., 60 sec., 120 sec., 300 sec., 600 sec., 1800 sec., 3600 sec. |
| Sensor Type | Rtd, Thermocouple |
| Storage Temp. | 14°F to 140°F |
| Temp. Range | -199.99° to +850°, -327.9° to +1562° |
| Temperature Meter Type | Multichannel Thermocouple Temperature Meter With Data Output And Min/Max |
| Temperature Range | -148°F to +3092°F (Thermocouple), -327.9°F to +1562°F (Rtd) |
| Thermocouple Temperature Range C | -100°C to 1150°C (type j),-100°C to 1300°C (type k),-100°C to 400°C (type t),-100°C to 900°C (type e), 0°C to 1500° (type s), 0°C to 1700°C (type r) |
| Thermocouple Temperature Range F | -148°F to 1652° (Type E), -148°F to 2102°F (Type J), -148°F to 2372°F (Type K), -148°F to 752°F (Type T), 32°F to 2732°F (Type S), 32°F to 3092°F (Type R) |
| Tripod Mountable | Yes |
| Type | 4 Channel Thermocouple, 2 Channel RTD |
Shipping Info:
| Ship weight (kg) | 0.63 |
| Ship height (cm) | 2.54 |
| Ship length (cm) | 2.54 |
| Ship width (cm) | 2.54 |
| Country of Origin | TW |
Product Details:
REED Instruments R2450SD data logging thermometer is ideal for recording temperatures, up to 3092 degrees F, either manually or automatically at the desired sampling rate from 1 to 3600 seconds. This data logging thermometer comes with a beaded wire probe, a soft carrying case & batteries for use in medical, educational, R&D, pharmaceutical, food service and environmental monitoring applications.
Features:
- REED Instruments R2450SD data logging thermometer displays up to 4 separate temperature measurements in an easy-to-read backlit LCD using Type K, J, R, S, E & T thermocouples and RTD probes.
- It can manually record up to 99 readings and automatically store data in real-time using an SD memory card.
- This data logging thermometer can measure current temperature, temperature differential (T1-T2) and maximum & minimum temperature to quickly produce an Excel file without using any software.
- It has a data hold function to freeze the reading (on display) and a user-selectable temperature unit scale (degree C / degree F).
- This data logging thermometer has a low battery indicator & an auto shut off mechanism (after 10 minutes) for saving battery life.
- It uses 6 AA batteries or an AC adapter for powering the unit.
- This data logging thermometer is operated at temperatures ranging from 32 to 122 degrees F (0 to 50 degrees C) and humidity less than 85% RH.
Compatible Accessories:
- REED Instruments R8888 Hard Carrying Case: It allows easy storage & transportation of this data logging thermometer.
- REED Instruments R1500 Tripod: It setups this data-logging thermometer for long-term continuous monitoring.
- REED Instruments RSD-ADP-NA & RSD-ADP-EU Power Supply Units: These 110V & 220V power supply adapters save the unit's battery life when working indoors near a power outlet.
Standards and Approvals:
- CE
Frequently Asked Questions:
Q. How to measure the difference between two temperature measurements in this REED Instruments R2450SD data logging thermometer?
A.
- Insert two thermocouple probes in the unit's T1 & T2 input jacks or two RTD (Pt100 Ohm) probes in the PT1 & PT2 input jacks.
- To view the temperature difference between the probes, hold the 'T1-T2' button for 2 seconds.
- Press & hold the 'T1-T2' button again for 2 seconds to resume normal operation.
Q. How to record maximum & minimum readings in this REED Instruments R2450SD data logging thermometer?
A.
- Enter recording mode by pressing the REC button. The 'REC' icon should display on the LCD. The meter should now start recording maximum & minimum readings.
- Press the REC button once to display the maximum value as indicated by the 'REC MAX' icon.
- Press the REC button again to display the minimum value as indicated by the 'REC MIN' icon.
- Press & hold the REC button for two seconds to exit the recording mode & resume normal operation.
Q. What is the measurement range of this REED Instruments R2450SD data logging thermometer?
A.
- Type K Thermocouple: -148 to 2372 degrees F (-100 to 1300 degrees C)
- Type J Thermocouple: -148 to 2102 degrees F (-100 to 1150 degrees C)
- Type T Thermocouple: -148 to 752 degrees F (-100 to 400 degrees C)
- Type E Thermocouple: -148 to 1652 degrees F (-100 to 900 degrees C)
- Type R Thermocouple: 32 to 3092 degrees F (0 to 1700 degrees C)
- Type S Thermocouple: 32 to 2732 degrees F (0 to 1500 degrees C)
- RTD Pt100 Ohm Probes: -327.9 to 1562 degrees F (-199.9 to 850 degrees C)
Product Variants
| Product | Model | Display Type | Auto Power Off | Sampling Rate | Temp. Range | Data Logging | Battery Type | Memory | Data Hold | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
R2450SD-NIST | - | - | - | - | - | - | - | - | €435.70 | RFQ
|
![]() |
R3000SD | Digital | Auto Power Off | 1 sec. to 8 hrs., 59 min., 59 sec. | - | - | AA | - | Yes | €321.34 |
Explore Products
- VULCAN HART 00-854058-00001 Gasket, Heat Exchanger Casting, 5 x 5.2 x 5 Inch Size
- GLOBE SCIENTIFIC GVM-AS-PAD Dimpled Pad, 99 mm Diameter
- CAMRAIL SNIND2 Camrail Bolt Installation Tool, Blk Oxide, Gr. 8, Steel, Torx
- WESTWARD 4KU87 Digital Micrometer 0-1 Inch 0.0001 Ratchet
- CAMLOCK FITTINGS E125-BR Adapter, 1 1/4 Inch Size, Brass
- GATES 154L100 Square Tooth Timing Belt, 0.375 Inch Pitch, 41 Teeth
- BRADY WRAP-4-427 61386 Precut Label Roll, 1 1/2 x 1 Inch, Vinyl, Black on White, For 22 AWG to 16 AWG Wire Gauge
- HUBBELL WIRING DEVICE-KELLEMS SNAPGFTW15I Gfci Receptacle, 15A 125V, 2-P 3-W Grounding, 5-15R, Ivory
Popular Search Queries
Explore More
- ADD-A-LEVEL
- ARH
- DYNA-LIFT
- KEYSHAFT
- NOTCH EQUIPMENT
- Wire Disconnects
- Line Voltage Thermostats
- Hand Scrapers
- Cable Pulling Jaw Grips
- Hydronic Baseboard Heaters
- DESTACO 235 Series Horizontal Hold Down Clamps
- LOC-LINE In-line Check Valve
- CONDOR Cowhide Leather Driver Gloves, Cinch Cuff, Yellow
- CONDOR Premium Work Gloves
- WRIGHT TOOL 1/2 Inch Drive Sets
- TB WOODS Speed Reducer Kit
- PROSENSE SC6 Series Temperature Transmitters
- NIBCO 4811 Series Sanitary Tees, H x H x H, PVC DWV
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
REED INSTRUMENTS R2450SD Thermocouple Thermometer, 2 Channels
€424.47 /unit