FRIEDRICH SH20M30B Hazardous Location Room Air Conditioner, 21000/21000 BTUH, 230/208V | CE6MYE SH20M30

FRIEDRICH SH20M30B SH20M30 Hazardous Location Room Air Conditioner, 21000/21000 BTUH, 230/208V

Item: CE6MYEModel: SH20M30BCross Ref: 35MW48 / SH20M30
In Stock

Get it by Tuesday, Dec 23

€6,668.73
10.00% off
€6,001.86 /unit
Add To Cart
Request a Quote

Payment

Delivery

Product Specifications:

Item Hazardous Location Air Conditioner
Air Flow Direction 8 Way
Amps 8.5/9.4A
Btuh Cooling 19000 btuH
Cfm 375 CFM
Chassis Type Medium
Class Class 1, DIV 2, GROUPS A, B, C AND D.
Color Gray
Control Type Mechanical
Cooling Capacity 21000 btuH
Cooling Capacity 21000/ 21000 BTUH, 6.15kW
Dehumidification 5.5 Pts/Hr.
Dehumidification Rate 5.5 lbs./hr.
Depth 27 3/8"
Duty Rating Commercial Grade
Eer 9.7/9.6
Fits Wall Sleeve - H X W X D 17 15/16" x 25 15/16" x 27 3/8"
Frequency 60 Hz
Heating Method Cooling Only
Height 17.938"
Includes Filter For Protection Against Fungal And Bacterial Growth, Seacoast Protection, Sleeve And Chassis, Washable
Max. Wall Thickness 6"
Mounting Sleeve Included Yes
Nema Plug Configuration - Hvac Hardwired
Number Of Speeds 1
Operation Mode - Hvac Cooling Only
Product Datasheet friedrich-sh15m30a.pdf
Programming Capability Not Programmable
Refrigerant Type R-410A
Remote Control Functions No Remote Control Included
Seacoast Corrosion Protection Rear Coil
Smart Connectivity No Connectivity
Voltage 208/230V AC
Watts 1965/1970 W
Width 25 15/16"

Shipping Info:

Ship weight (kg) 81.45
Ship height (cm)45.56
Ship length (cm)69.53
Ship width (cm)65.88
Country of OriginMX

Product Details:

Friedrich Hazardgard Series SH20M30B air conditioner is designed for use in environments with flammable gases, vapours or dust. It is crucial in the oil & gas, petrochemical, chemical manufacturing and mining industries to cool down the workplaces. This air conditioner maintains a controlled temperature and avoids heat accumulation.

Features:

  • Friedrich SH20M30B air conditioner has a hermetically sealed reciprocating compressor that allows it to tolerate outdoor temperatures up to 130 degrees F (55 degrees C).
  • This unit has a hot gas bypass that allows it to operate during ambient cooling to 45 degrees F (7 degrees C) without freezing.
  • It has a slide-out chassis that allows easy installation and maintenance.
  • This Friedrich Hazardgard Series SH20M30B air conditioner has an environmentally sealed switch and gold-plated contacts for corrosion resistance.
  • It has solid-state contact relays for adequate compressor and fan operation.
  • This air conditioner has an enclosed fan motor for arc-free operation.
  • It also has a direct-wired 15A circuit with a time delay fuse that tolerates current surge and does not trip the breaker.
  • This Friedrich air conditioner has a stainless steel fan shaft to avoid debris ingress.
  • Its 22 gauge, G60 steel cabinet is powder-coated (also known as Diamonblue Advanced Corrosion Protection) and for long life.

Frequently Asked Questions:

Q. What is the recommended wall thickness for this air conditioner's installation?

A. You can install this Friedrich air conditioner in walls that are six inches thick or less.

Q. How to troubleshoot Friedrich SH20M30B air conditioner?

A. To see if your air conditioner is working properly, look for electrical problems, refrigerant leaks and sensor problems. Also, check the air filter for dirt accumulation.

Q. Can this air conditioner maintain humidity?

A. Friedrich air conditioners can maintain humidity in labs, control rooms, storage spaces and habitations. It operates at a dehumidification rate of 5.5 pints per hour to maintain comfort in your workspaces.

Q. How can I ensure the longevity of my air conditioning unit?

A.

  • Periodically clean the air filters and adhere to scheduled servicing.
  • Also, regularly inspect the area around your outdoor air conditioning unit to ensure it is free from leaves and debris. It will prevent the accumulation of dirt, contributing to the prolonged functionality of your air conditioner.
  • Ensure that your furniture layout does not obstruct the air grills and ductwork, which can impede proper airflow.
  • To minimise heat intrusion, consider using blinds and shades on west and south-facing windows.

Documentation:

Datasheet

Product Variants

ProductModelBtuh CoolingVoltageControl TypeCfmColorEerHeightWattsPrice
FRIEDRICH SH20M50B Hazardous Location Room Air Conditioner, 21000/19100 BTUH, 240/220V | CE6GEA SH20M50B21000 btuH, 19000 btuH-Rotary425 CFMWhite8.817.938"1965/1970 W€8,550.00
FRIEDRICH SH15M30A Hazardous Location Room Air Conditioner, 15700/15700 BTUH, 230/208V | CE6MYD SH15M30 SH15M30A14500 btuH, 14000 btuH230/208V-375 CFMWhite9.715.938"1495/1443 W€5,241.99
FRIEDRICH SH24N30A Hazardous Location Room Air Conditioner, 24000/24000 BTUH, 230/208V | CE6MYF SH24N30A24000 btuH, 23700 btuH208/230V ACMechanical385 CFMGray8.5:8.817.938"2727/2788 W€5,241.99

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

FRIEDRICH SH20M30B SH20M30 Hazardous Location Room Air Conditioner, 21000/21000 BTUH, 230/208V
€6,668.73 /unit