EATON E2LW Type Mining Complete Molded Case Circuit Breakers
Eaton E2LW mining complete MCCBs are used in mining applications for protection against hazardous faults like short circuits and overload conditions.
Filter
| Style | Model | Amps | Trip Rating | Height | No. Of Poles | Voltage | Circuit Breaker Type | Interrupt Rating | Circuit Breaker Frame Type | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | E2LW3300W | 300A | 1500-3000A | 7" | 3 | - | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3320W | 320A | 1600-3200A | 7" | 3 | - | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3350W | 350A | - | 7" | 3 | - | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €17,822.41 | |
| A | E2LW3400W | 400A | 2000-4000A | 7" | 3 | - | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450MNW | 450A | 1500-3000A | 7" | 3 | - | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450MYW | 450A | 2250-4500A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €20,348.83 | |
| A | E2LW3450MVW | 450A | 1600-3200A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450MRW | 450A | 1750-3500A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450MLW | 450A | 1125-2250A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450MXW | 450A | 2000-4000A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | €18,545.55 | |
| A | E2LW3450W | 450A | 2250-4500A | 7" | 3 | 1200V AC | E2LW | 10 kAIC at 1200V AC | Complete Breaker | - | RFQ
|
Features
- Eaton E2LW mining complete MCCBs feature a built-in test port for comfortable field testing.
- They are equipped with L-frames for stability during operation.
- These 3-pole breakers come with fast clearing fault times for improved safety during the maintenance process.
- They have an operating trip rating ranging from 1150 to 4500A.
- These MCCBs use interchangeable magnetic trips for changing the breaker trip setting by switching out a trip unit module.
Compatible Accessories
- Eaton Auxiliary Switches: These switches indicates if the breaker contacts are open or closed.
- Eaton Shunt Trips: They provide distant control tripping and contain a plug-in module-mounted intermittent rated solenoid with a tripping plunger and a cutoff switch.
- Eaton Bell Alarms: They have a break indicator, a rotational and Flex Shaft handle mechanism and an electronic operator for faraway operation.
Standards and Approvals
- UL
- CSA
Frequently Asked Questions
What is the interrupt rating of Eaton E2LW mining complete MCCBs?
10kAIC at 1200VAC.
What is the ampere rating of these mining circuit breakers?
450
What is the voltage rating of these MCCBs?
1200VAC.
We are here to help!
Looking for a part not listed here?
Explore More
- JET TOOLS
- KEYSHAFT
- WEISS
- CUSHMAN
- MIDWEST
- Miniature Lamps and Bulbs
- Car Dollies
- Bolt On Miniature Circuit Breakers
- Dock Lights
- Basket Trucks
- MEMPHIS GLOVE Deerskin Leather Palm Gloves
- ANSELL 11-818 Hyflex Ultralight Multi Purpose Gloves
- JOHN GUEST Male Connectors, BSPT Thread, Acetal Gray
- GLOBE SCIENTIFIC Tri-Corner Beakers, Economy Style
- ANVIL AS1200 Series O.D. Tubing Clamps, Zinc Trivalent Chromium
- CDI CONTROL DEVICES Float Valve Lead-free Brass Pipe Mount
- PETERSEN PRODUCTS 151 Series Pipe Plug
- LOVEJOY C Type Universal Hubs With Center, Imperial
- STARRETT 99907 Series Intenss PRO Bi-Metal Band Saw Blades
- DIXON Automatic Weld Ferrules