Product Specifications:
| Item | Plug In Circuit Breaker |
| Ac Voltage Rating | 120/240V AC |
| Amps | 20A |
| Circuit Breaker Actuator | Paddle |
| Circuit Breaker Mounting Style | Plug In |
| Circuit Breaker Type | Ground Fault Equipment Protection (30 mA) |
| Compatible Panelboard/load Center Series | NQ, QO |
| Dc Voltage | Not Rated |
| Dc Voltage Rating | Not Rated |
| Depth | 2.91" |
| For Use With | QO Load Centers And NQ Panelboards |
| Frame Size | 100A, QO |
| Frequency | 50/60 Hz |
| Length | 4.12" |
| Max. Air Rating | 10kA |
| Max. Air Rating | 10 kA At 120V AC |
| Max. Wire Size | 8 AWG |
| Minimum Wire Size | 12 AWG, 14 AWG |
| Mounting Type | Plug In |
| Number Of Poles | 2 |
| Number Of Spaces | 2 |
| Phase | Single |
| Product Datasheet | square-d-qo110.pdf |
| Temp. Rating | 140 Deg. F |
| Temp. Rating | 140°F |
| Terminal Connection | Pressure Plate |
| Terminal Connection Type | Screw Clamp |
| Type | Standard |
| Use With | QO Series |
| Width | 1 1/2" |
| Wire Size | 14 AWG |
Shipping Info:
| Ship weight (kg) | 0.41 |
| Ship height (cm) | 7.39 |
| Ship length (cm) | 10.46 |
| Ship width (cm) | 3.81 |
| HS code | 8536200020 |
| Country of Origin | MX |
Product Details:
Square D QO220EPD plug-in circuit breaker is used in commercial electrical panels to protect against overloads and ground faults, ensuring safe and reliable electrical distribution. This circuit breaker features an over centre, trip-free toggle mechanism with quick make, quick break action and clear handle indication for ease of operation. It offers a VisiTrip trip indication for circuit interruption and allows plug-in mounting for secure installation. This 2-pole QO circuit breaker is rated at 20A for 120 / 240VAC and has a breaking capacity of 10kA.
Frequently Asked Questions:
Q. How do I install Square D QO220EPD plug-in circuit breaker?
A.
- Turn off main power supply.
- Open electrical panel door.
- Choose available slot.
- Slide breaker on bus bar.
- Push until it clicks securely.
- Connect wires to breaker.
- Close panel door.
- Turn main power back on.
Q. What factors should I consider while choosing a circuit breaker?
A.
- Match breaker capacity to load.
- Choose suitable type (standard or GFCI).
- Ensure compatibility with system voltage.
- Evaluate breaking capacity for short circuits.
- Check fit within electrical panel.
- Consider residential or industrial use.
Q. Does Raptor Supplies offer similar circuit breaker with higher amperage rating?.
A. Yes, customers searching for similar circuit breakers with higher amperage ratings can opt for Square D QO130EPD and QO350EPD circuit breakers having amperage ratings of 30 and 50A, respectively
Documentation:
Product Variants
| Product | Model | Phase | Number Of Poles | Amps | Ac Voltage Rating | Max. Air Rating | Dc Voltage Rating | Depth | Terminal Connection | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
QO120EPD | Single | 1 | 20A | 120V AC | 10 kA At 120V AC | Not Rated | 2.91" | Pressure Plate | €763.89 | |
![]() |
QO130EPD | Single | 1 | 30A | 120V AC | 10 kA At 120V AC | 48V | 2.91" | Pressure Plate | €743.50 | |
![]() |
QO215EPD | Single | 2 | 15A | 120/240V AC | 10 kA At 120/240V AC | 48V | 2.91" | Pressure Plate | €1,260.54 | |
![]() |
QO230EPD | Single | 2 | 30A | 120/240V AC | 10 kA At 120/240V AC | Not Rated | 2.91" | Pressure Plate | €1,247.88 | |
![]() |
QO115EPD | Single | 1 | 15A | 120V AC | 10 kA At 120V AC | 48V | 2.91" | Pressure Plate | €763.89 | |
![]() |
QO225EPD | Single | 2 | 25A | 120/240V AC | 10 kA At 120/240V AC | 48V | 2.91" | Pressure Plate | €1,222.48 | |
![]() |
QO250EPD | Single | 2 | 50A | 120/240V AC | 10 kA At 120/240V AC | 48V | 2.91" | Lug | €1,240.55 |
Explore Products
- EATON JGU4250NN Molded Case Circuit Breaker, 600 VAC, 250A, 200/150/50 kA Interrupt, 4P
- MITUTOYO 500-166 w/cert Absolute Digital Caliper 0 To 12 Inch
- WALTER TOOLS DC150-03-14.288A1-WJ30RE 6968866 Jobber Length Drill Bit, 9/16 Inch Size Size, 4 1/2 Inch Overall Length
- PRECISION BRAND 44710 Arbor Shim 0.0150 x 3/8 Id Pink
- LEGRIS 3306 06 04 Metric Push-to-Connect Fitting, Polymer, 6 mm x 4 mm x 4 mm Tube OD
- CASH VALVE GT11311487 Valve Body, 1/2 Size, Type Fr10
- LIFT-ALL 2T210X10 Wire Mesh Sling, 10 Ft Sling Length, 2300 Lb Vertical Hitch Capacity
- APPROVED VENDOR 1MMY5 Tee 2 Inch Npt
Explore More
- FSI
- KEYSHAFT
- CLE-FORCE
- ELC SECURITY PRODUCTS
- MCQUAY DAIKIN
- Locknuts
- Ergonomic Workbenches
- Digital Pressure and Vacuum Gauges
- Gouging Electrodes
- Air Scarifier Accessories
- LEATHERHEAD TOOLS SET Tools, Halligan Bars
- MEMPHIS GLOVE Luminator Pigskin Leather Palm Work Gloves
- MUELLER INDUSTRIES 107MAT Silent Check Valves
- SUGATSUNE Pull Handles, 316 Stainless Steel
- ANVIL AS793 Series Close Angle Connectors, 4-Hole
- FASCO Shaded Pole Open Air-Over HVAC Motors
- MACROMATIC 24VAC, Pump Seal Failure Relay
- APPLETON ELECTRIC Selector Switch Assemblies, 2 Position Operator
- PARKER Hydraulic Directional Valves
- GRAINGER Rectangular Carbon Steel Tubes
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.