Product Specifications:
| Item | Miniature Circuit Breaker |
| Ac Voltage Rating | 277/480V AC |
| Amps | 4A |
| Application | Motor Control Circuits, Industrial Controls And Automation, Communication Equipment, Computers, Medical Equipment, Relays, Ups, Hacr Equipment (Heating, Air Conditioning, Refrigeration) (Internal/External) |
| Circuit Breaker Actuator | Toggle |
| Circuit Breaker Mounting Style | DIN Rail |
| Curve Type | C |
| Dc Voltage Rating | 48V DC |
| Depth | 4.13" |
| Frame | 40A/FAZ |
| Length | 0.7" |
| Max. Air Rating | 10 kA At 277/480V AC |
| Max. Air Rating | 10kA |
| Max. Operating Temp. | 140°F |
| Max. Wire Size | 6 AWG |
| Meets Ul Type | UL 489 |
| Min. Operating Temp. | -4°F |
| Min. Wire Size | 18 AWG |
| Mounting Style | Din Rail |
| Number Of Poles | 1 |
| Phase | 1 |
| Series | FAZ-NA Series |
| Terminal Connection | Screw Clamp |
| Trip Type | Thermal Magnetic |
| Voltage Type | AC/DC |
| Width | 2.97" |
Shipping Info:
| Ship weight (kg) | 0.14 |
| Ship height (cm) | 10.49 |
| Ship length (cm) | 1.78 |
| Ship width (cm) | 7.54 |
| HS code | 8536.20 |
| Country of Origin | RO |
Product Details:
Eaton FAZ-C4/1-NA-SP miniature circuit breaker is used to protect from medium-level short circuit faults, such as in lighting, coils & control panels.
Features:
- It features a thermal-magnetic trip to provide both long-time and instantaneous current limiting protection.
- This C-curve circuit breaker comes equipped with a toggle actuator for manual action.
- It allows DIN rail mounting to minimise the installation & wiring downtime.
- This circuit breaker has a 4A standard current rating and a maximum interrupting capacity of 10kAIC at 277 / 480VAC.
- It can accommodate wire sizes ranging from 18 to 6 AWG.
Standards and Approvals:
- UL
- CSA
- IEC 60947-2
Frequently Asked Questions:
Q. What is the operating temperature range of Eaton FAZ-C4/1-NA-SP miniature circuit breaker?
A. This circuit breaker can be operated at temperatures ranging from -4 to 140 degrees F.
Q. What causes miniature circuit breakers to trip?
A. Overloading a circuit is the primary reason for frequent short-circuit tripping.
Q. What is the difference between MCCBs and MCBs?
A.
- MCBs protect items from current overloads while MCCBs protect equipment from fault currents & excess temperature rise.
- The tripping circuit of MCBs is fixed while MCCBs have a movable tripping circuit.
- MCBs have comparatively low interrupting ratings than MCCBs.
Q. Which type of terminal connection is used in this circuit breaker?
A. This circuit breaker uses a screw clamp connection for added safety.
Product Variants
| Model | Ac Voltage Rating | Max. Air Rating | Number Of Poles | Dc Voltage Rating | Curve Type | Price | |
|---|---|---|---|---|---|---|---|
| FAZ-C20/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| FAZ-C25/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| FAZ-C30/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| FAZ-C32/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €262.80 | |
| FAZ-C1/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| FAZ-C2/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| FAZ-C3/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 |
Explore Products
- BOSTON GEAR 28164 Helical Speed Reducer
- AUTOQUIP TTN-036-0020 Scissor Lift Table, 36 Inch Platform Width, 42 Inch Height, 2000 lbs Capacity
- THOMAS & BETTS CI7304 Iberville Fitting, Pull Elbow, Rigid To Rigid, Trade Size 1/2 Inch, Zinc Alloy
- APPLETON ELECTRIC YE1950824A
- AMETEK LAMB 516693 516693000 Lip Seal
- VULCAN HART SC-115-21 Screw
- COOPER B-LINE SB747V2315AFB Mounted Shelf, Aluminium, 12-24 Mounting Hardware, Black Powder Coat
- MERIT BRASS 3612D-2408 Reducing Coupling, 1-1/2 x 1/2 in Nominal, FNPT End Style, 3000 lb
Explore More
- KEYSHAFT
- KUSHLAN PRODUCTS
- ULTEM
- YOUNG BROS. STAMP WORKS
- ELKAY PLASTICS
- Electric Floor Heating Kit Accessories
- Engravers
- Right-To-Know Stations
- Window/Wall A/C Heat Pump Accessories
- Chin Straps
- AMERIC Duct To Duct Connectors, 5.375 Inch Length
- DWYER INSTRUMENTS TID Series Temperature/Process Indicators
- CONDOR Electrical Gloves Protector, White, Shirred Slip-On Cuff
- RUD CHAIN WPPH-B Powerpoint Ring Connection Hoist Rings
- VULCAN HART Union
- EATON E34 Series Selector Switch Units
- RAVAS RCS Hydraulic Scale
- FIREYE Resets
- TEXAS PNEUMATIC TOOLS Repair Kits
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
EATON FAZ-C4/1-NA-SP IEC Miniature Circuit Breaker, 4 A, 48 VDC, 10kA at 277/480 VAC, Screw Clamp, FAZ-NA