Eaton FAZ-NA Series miniature circuit breakers (MCBs) provide protection against electrical circuits from overloads, short circuits and ground faults. These units are used in applications, including motor control circuits, PLC I/O points, HACR equipment, power supplies, relays, UPS and power conditioners. ...Read more
| Style | Model | Ac Voltage Rating | Max. Air Rating | Number Of Poles | Dc Voltage Rating | Curve Type | Price | |
|---|---|---|---|---|---|---|---|---|
| A | FAZ-C35/1-NA-SP | 240V AC | 10 kA At 240V AC | 1 | 48V DC | C | €135.00 | |
| B | FAZ-D40/3-NA | 240V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | D | €701.42 | |
| C | FAZ-C40/3-NA | 240V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €533.11 | |
| D | FAZ-D40/2-NA | 240V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €384.45 | |
| A | FAZ-D40/1-NA-SP | 240V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| D | FAZ-C40/2-NA | 240V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €262.80 | |
| A | FAZ-D7/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €124.20 | |
| D | FAZ-D4/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €353.98 | |
| A | FAZ-C25/1-NA-SP | 277/480V AC | 14 kA At 277/480V AC | 1 | 48V DC | C | €109.80 | |
| A | FAZ-C8/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| A | FAZ-C2/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| C | FAZ-D5/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | D | €527.28 | |
| C | FAZ-C35/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €630.97 | |
| C | FAZ-C15/3-NA | 277/480V AC | 14 kA At 277/480V AC | 3 | 48/96V DC | C | €490.06 | |
| C | FAZ-C6/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €541.52 | |
| C | FAZ-C1/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €575.74 | |
| D | FAZ-C16/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| A | FAZ-D6/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | - | €124.20 | |
| A | FAZ-D3/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| A | FAZ-D4/1-NA-SP | 277/480V AC | 10 kA | 1 | 48V DC | D | €135.00 | |
| A | FAZ-D35/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| A | FAZ-D5/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| A | FAZ-D16/1-NA-SP | 277/480V AC | 10 kA | 1 | 48V DC | D | €124.20 | |
| A | FAZ-D15/1-NA-SP | 277/480V AC | 14 kA At 277/480V AC | 1 | 48V DC | D | €124.20 | |
| A | FAZ-D13/1-NA-SP | 277/480V AC | 14 kA At 277/480V AC | 1 | 48V DC | D | €124.20 | |
| A | FAZ-D10/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €124.20 | |
| A | FAZ-D8/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €124.20 | |
| D | FAZ-C6/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| D | FAZ-C15/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| D | FAZ-C5/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €262.80 | |
| C | FAZ-D4/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | D | €508.30 | |
| C | FAZ-D3/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | D | €447.81 | |
| C | FAZ-C30/3-NA | 277/480V AC | 10 kA | 3 | - | C | €480.26 | |
| C | FAZ-C10/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €505.00 | |
| C | FAZ-C5/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €481.61 | |
| C | FAZ-C4/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €464.31 | |
| D | FAZ-D7/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €262.48 | |
| D | FAZ-D1/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €353.93 | |
| D | FAZ-C10/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €250.20 | |
| D | FAZ-C3/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €262.80 | |
| A | FAZ-C6/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | - | €124.20 | |
| C | FAZ-C32/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €389.34 | |
| A | FAZ-D1/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| C | FAZ-C13/3-NA | 277/480V AC | 10 kA At 277/480V AC | 3 | 48/96V DC | C | €447.65 | |
| D | FAZ-D35/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €296.57 | |
| D | FAZ-D32/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €352.45 | |
| D | FAZ-D30/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €354.23 | |
| D | FAZ-D25/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €388.64 | |
| D | FAZ-D20/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | D | €329.94 | |
| D | FAZ-D16/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | D | €391.24 | |
| D | FAZ-D15/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | D | €439.17 | |
| D | FAZ-D13/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | D | €340.87 | |
| D | FAZ-D10/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €334.81 | |
| D | FAZ-D3/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €432.17 | |
| A | FAZ-D2/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | D | €135.00 | |
| D | FAZ-C25/2-NA | 277/480V AC | 14 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 | |
| A | FAZ-C40/1-NA-SP | 277/480V AC | 10 kA | 1 | 48V DC | C | €135.00 | |
| D | FAZ-D2/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | D | €361.44 | |
| A | FAZ-C15/1-NA-SP | 277/480V AC | 14 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| A | FAZ-C5/1-NA-SP | 277/480V AC | 10 kA At 277/480V AC | 1 | 48V DC | C | €124.20 | |
| D | FAZ-C30/2-NA | 277/480V AC | 10 kA At 277/480V AC | 2 | 48/96V DC | C | €241.20 |
Working Mechanism
- Eaton miniature circuit breaker opens the circuit when the current passing through the circuit exceeds the pre-determined setting, thereby protecting the equipment from fire hazards.
- When there is an overload in the current, the bi-metallic strip (present in the breaker) heats up and bends.
- This bending action causes the trip mechanism to activate and open the circuit breaker, thus interrupting the current flow.
- During an event of a short circuit, a large number of current flows through the circuit breaker, causing a strong magnetic field.
- This magnetic field causes the trip mechanism to activate and open the circuit breaker to stop the current flow.
Features
- These MCBs feature a thermal-magnetic trip that offers protection from both short circuits and overcurrent conditions.
- They come with a current limiting design that provides fast short-circuit interruption, which helps reduce let-through energy and prevents damage to the circuit.
- They incorporate DIN rail mounting that offers hassle-free installation and eliminates loose connection against vibration and thermal cycling.
- They also include a trip-free toggle mechanism, colour-coded breaker status indicator and IP20 finger & hand touch safe enclosure providing additional safety to personnel and equipment.
Standards and Approvals
- UL
- CSA
- IEC
Frequently Asked Questions
What is a C curve breaker?
C curve miniature circuit breakers are applied where the loads have a small amount of in-rush current on start-up. These breakers trip between 6-10 times the rated current in such short circuit conditions.
What are FAZ-NA Series miniature circuit breakers used for?
These FAZ-NA Series miniature circuit breakers are ideal for branch circuit device protection and can also be reversed fed for maximum protection of personnel, installation and plant.
What is the purpose of trip-free toggle mechanism?
The trip-free toggle mechanism ensures that the circuit breaker cannot be manually held in the closed position if it has tripped due to overcurrent or a short circuit. It will automatically open and trip to the off position even if the toggle handle is held in the closed position, thus protecting the equipment against hazards.
We are here to help!
Looking for a part not listed here?
Explore More
- DAVIS INSTRUMENTS
- HAMILTON
- KEYSHAFT
- KUNKLE
- ROTRON
- Locking Pliers
- Socket Bits
- Fire and Rescue Helmets
- Reduced Shank Drill Bits
- Compressed Air Filters
- HELICOIL Straight Flute Plug Taps, UNF, 3B
- TURTLESKIN CP-430 Insider Gloves
- KEO NC Spotting Drills, 82 Degrees Point Angle
- MUELLER INDUSTRIES 103MAT Silent Check Valves
- ANVIL AS520BTB Series Welded Channels
- APPROVED VENDOR Heavy Duty Shelving Bracket
- LEESON SST Duck Washguard Motors, Single Phase, TEFC, C Face With Base
- APOLLO VALVES 83B-540 Series 3 Piece Full Port Butt Weld Ball Valves
- DAYTON Floor Stand Drill Presses for Metal
- ENERPAC Jam Nuts