Product Specifications:

Item Reduced Press. Zone Assembly
Backflow Preventer Type Reduced Pressure Assembly (Rp)
Body Material Bronze
Check Mechanism Material Glass Filled Ppo
Check Valve Length 7 3/8"
Connection Gender - Side 1 Female
Connection Gender - Side 2 Female
Connection Size - Side 1 1/2"
Connection Size - Side 2 1/2"
Connection Type FNPT
Connection Type - Side 1 NPT
Connection Type - Side 2 NPT
Cracking Pressure 5 psi
Flow Rate 15 GPM
For Media Water
Freeze Protection No
Handle Material Stainless Steel
Hazard Protection Level High Health Hazard
Height 7 1/8"
Includes No Items
Includes Atmospheric Vent No Atmospheric Vent
Includes Flood Protection No Flood Protection
Includes Freeze Protection No Freeze Sensor
Includes Strainer No
Length 11 1/8"
Manufacturer Warranty 5 yrs.
Material Bronze
Max. Operating Pressure 175 psi
Max. Pressure (cwp) 175 psi
Max. Temp. 180°F
Media Temp. Range 33°F to 180°F
Mounting Orientation Horizontal
Number Of Test Ports 4
Overall Length 10.88"
Overall Width 2 22/25"
Pipe Size 1/2"
Product Datasheet apollo-valves-4a207a2f.pdf
Protection Type Back Pressure, Back Siphonage
Seat Material Silicone
Series 4A Series Backflow Preventers
Shut-off Valve Type Ball Valve
Size 1/2"
Spring Material Stainless Steel
Suitable For Central Heating Water No
Temp. Range 33°F to 180°F
Valve Series 4A
Width 2 7/8"

Shipping Info:

Ship weight (kg) 3.47
Ship height (cm)10.67
Ship length (cm)38.61
Ship width (cm)24.13
HS code8481301090
Country of OriginUS

Product Details:

Apollo Valves 4ALF203A2F reduced pressure zone backflow preventer protects water supplies from contamination. It prevents the reverse flow of potentially harmful substances into the clean water system. This valve is useful in healthcare facilities, chemical processing plants and food manufacturing facilities to prevent the backflow of pollutants, chemicals or pathogens into their water systems.

Features:

  • Apollo Valves 4ALF203A2F backflow preventer has a straight valve configuration for ease of installation.
  • It comes with SAE threaded end connections, ensuring secure fittings.
  • This backflow preventer includes a modular captured spring relief valve for efficient pressure regulation.
  • It further features a check valve cartridge to prevent backflow contamination.
  • This Apollo backflow preventer has a top-mounted test cock for convenient testing and maintenance.
  • It features an internal sensing passage for accurate pressure monitoring.
  • Apollo Valves 4ALF203A2F backflow preventer includes a bronze cap for durability and corrosion resistance.
  • It features a chloramine-resistant EPDM O-ring seal for leak-proof connections.
  • Apollo Valves 4ALF203A2F backflow preventer is lead-free and safe for use in drinking water systems.

Frequently Asked Questions:

Q. How do I know if my Apollo 4ALF203A2F backflow preventer is operating correctly?

A. Regular visual inspections can help identify any visible signs of damage or malfunction, such as leaks, corrosion or debris accumulation. Additionally, annual testing by a certified professional is essential to ensure proper operation and compliance with safety standards.

Q. What are some common maintenance tasks for a backflow preventer?

A. Routine maintenance tasks include cleaning and lubricating valves, inspecting for leaks or damage, testing pressure levels and replacing worn-out parts as needed. For more information, check out our comprehensive guide on backflow preventers.

Q. What are the consequences of not using a reduced pressure zone backflow preventer?

A. Without an RPZ backflow preventer, there is a risk of contamination of clean water supplies, which can lead to serious health hazards, legal liabilities and damage to equipment and infrastructure.

Q. What steps should I take if I suspect backflow contamination in my water system?

A. If you suspect backflow contamination in your water system, immediately shut off the water supply to prevent further contamination and potential health risks.

Q. Are there any precautions I should take when restarting my water system after maintenance or repairs on the backflow preventer?

A.

  • Slowly open the water supply valves to restore water flow & pressure gradually.
  • Monitor for any unusual fluctuations / leaks and conduct functional checks to verify that the backflow preventer is operating correctly before resuming normal operations.

Documentation:

Datasheet

Product Variants

ProductModelConnection TypeHeightTemp. RangeOverall HeightBody MaterialSeat MaterialMax. PressureCracking PressurePrice
APOLLO VALVES 4ALF204A2F Reduced Pressure Zone Backflow Preventer | AD3LZQ 40D853 / 4ALF-204-A2F 4ALF204A2FFNPT7 3/8"33°F to 180°F7.38"BronzeSilicone-5 psi€910.35
APOLLO VALVES 4ALF205A2F Reduced Pressure Zone Backflow Preventer | AD3LZR 40D854 / 4ALF-205-A2F 4ALF205A2FFNPT8"33°F to 180°F8"BronzeSilicone-5 psi€879.16
APOLLO VALVES 4ALF206T2F Reduced Pressure Zone Backflow Preventer | AD3LZT 40D855 / 4ALF-206-T2F 4ALF206T2FFNPT9 7/8"+33°F to +180°F9.88"BronzeSilicone175 psi5 psi€1,353.53
APOLLO VALVES 4ALF207T2F Reduced Pressure Zone Backflow Preventer | AD3LZU 40D856 / 4ALF-207-T2F 4ALF207T2FFNPT9 7/8"+33°F to +180°F9.88"BronzeSilicone175 psi5 psi€1,670.47
APOLLO VALVES 4ALF208T2F Reduced Pressure Zone Backflow Preventer | AD3LZV 40D857 / 4ALF-208-T2F 4ALF208T2FFNPT11"+33°F to +180°F11"BronzeSilicone175 psi5 psi€1,885.16
APOLLO VALVES 4ALF20903 Reduced Pressure Valve, 2-1/2 Inch Size, Female x Female | BP3CEZ 4ALF20903Flange584.2 mm------€4,488.33
APOLLO VALVES 4ALF20G01 Reduced Pressure Valve, 10 Inch Size | BP3JHX 4ALF20G01--------€36,757.59

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

APOLLO VALVES 4ALF203A2F Reduced Pressure Zone Backflow Preventer, 4ALF-200, 1/2 in, FNPT, Lead Free Bronze, 4ALF-200
€910.59 /unit