GATES Chem Master Plus XLPE Chemical Hoses


Filter
StyleModelHose Inside Dia.ColorVacuum PressureContinuous Operating Temp.CautionWorking PressureMin. Bend RadiusCover TypePrice
A
46950729
1 1/2"Black30 in. hg-40°F to +250°FFor Applications Requiring Greater Than 90% Sulfuric Acid Contact Denver Product Application (303) 744-5070. Chem Master Plus Xlpe Is Designed To Withstand Fluid Temperatures To +250°F (+121°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C). Not Recommended For 'Closed Steam' Cleaning.200 psi8"EPDM - Type P€41.10
A
46960203
1 1/4"Yellow30 in. hg-40°F to +250°FChem Master EPDM Is Designed To Withstand Fluid Temperatures To +250°F (+121°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).150 psi4"EPDM - Type P€25.46
B
46980072
1"Blue20 in. hg-40°F to +300°FChem Master XTreme, FEP CR Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).200 psi5"EPDM - Type P€33.66
B
46980022
1"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).200 psi5"EPDM - Type P€74.94
B
46980029
1"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).200 psi5"EPDM - Type P€74.94
A
46960008
1"Black30 in. hg-40°F to +275°FChem Master Plus CPE Megaflex Is Designed To Withstand Fluid Temperatures To 275°F (135° C), However, The Rating Is Dependent Upon The Specific Chemical Being Conveyed. Contact Denver Product Application (303-744-5070) For Any Chemical Application Above 125°F (+52°C).200 psi2"EPDM - Type P€33.66
A
46960016
2"Black30 in. hg-40°F to +275°FChem Master Plus CPE Megaflex Is Designed To Withstand Fluid Temperatures To 275°F (135° C), However, The Rating Is Dependent Upon The Specific Chemical Being Conveyed. Contact Denver Product Application (303-744-5070) For Any Chemical Application Above 125°F (+52°C).200 psi4"EPDM - Type P€45.48
A
46960005
2"Yellow30 in. hg-40°F to +250°FChem Master EPDM Is Designed To Withstand Fluid Temperatures To +250°F (+121°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).150 psi6"EPDM - Type P€29.70
B
46980073
2"Blue20 in. hg-40°F to +300°FChem Master XTreme, FEP CR Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).200 psi9"EPDM - Type P€45.48
B
46980024
2"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).-9"EPDM - Type P€124.40
B
46980026
3"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).150 psi-EPDM - Type P€185.66
A
46960013
3"Yellow30 in. hg-40°F to +250°FChem Master EPDM Is Designed To Withstand Fluid Temperatures To +250°F (+121°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).150 psi11"EPDM - Type P€43.12
A
46960024
3"Black30 in. hg-40°F to +275°FChem Master Plus CPE Megaflex Is Designed To Withstand Fluid Temperatures To 275°F (135° C), However, The Rating Is Dependent Upon The Specific Chemical Being Conveyed. Contact Denver Product Application (303-744-5070) For Any Chemical Application Above 125°F (+52°C).150 psi8"EPDM - Type P€65.68
B
46980021
3/4"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).200 psi4"EPDM - Type P€63.72
A
46960007
3/4"Black30 in. hg-40°F to +275°FChem Master Plus CPE Megaflex Is Designed To Withstand Fluid Temperatures To 275°F (135° C), However, The Rating Is Dependent Upon The Specific Chemical Being Conveyed. Contact Denver Product Application (303-744-5070) For Any Chemical Application Above 125°F (+52°C).200 psi1 1/2"EPDM - Type P€30.57
A
46960025
4"Black30 in. hg-40°F to +275°FChem Master Plus CPE Megaflex Is Designed To Withstand Fluid Temperatures To 275°F (135° C), However, The Rating Is Dependent Upon The Specific Chemical Being Conveyed. Contact Denver Product Application (303-744-5070) For Any Chemical Application Above 125°F (+52°C).150 psi10"EPDM - Type P€81.99
B
46980027
4"Blue30 in. hg-40°F to +300°FChem Master XTreme, FEP Is Designed To Withstand Fluid Temperatures To +300°F (+149°C); However The Rating Is Dependent On The Specific Chemical Conveyed. Contact Denver Product Application (303) 744-5070 For Any Chemical Above +125°F (+52°C).125 psi24"EPDM - Type P€261.16

We are here to help!

Looking for a part not listed here?