EATON XT Series IEC Mini Contactors


Eaton XT-Series mini contactors are compact relay units that switch on / off an electric circuit. These full voltage non-reversing units are useful in compact machines, conveyors and PCB boards where saving space is a major concern.

Filter
StyleModelNo. Of PolesCoil VoltageHeightFrequencyAmpsMax. HpFull Load Amps-inductiveHp @ 3 Phase-208vPrice
A
XTMC6A10T
324V AC2 1/2"50/60 Hz6.6A1/4, 3/4, 1/ 1 1/2, 2, 3, 3 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)6A1 1/2 hp€138.66
B
XTMC6A10R
312V AC1.77"50/60 Hz--6A1 1/2 hp€137.15
A
XTMC6A10A
3110-120V AC2 1/2"50/60 Hz6.6A-6A1 1/2 hp€138.66
C
XTMC6A01T
324V AC1.77"50/60 Hz--6A2 hp€156.65
C
XTMC6A01B
3240V AC1.77"50/60 Hz--6A1 1/2 hp€156.65
D
XTMC9A01T
324V AC2"50/60 Hz8.8A-9A2 hp€205.96
E
XTMC6A01TD
324V DC2"50/60 Hz6.6A-6A2 hp€201.44
E
XTMC6A01A
3110/120V AC2"50/60 Hz6.6A-6A2 hp€156.65
B
XTMC6A10E
3208V AC1.77"60 Hz--6A1 1/2 hp€138.66
F
XTMC9A10A
3-2 1/2"-8.8A-9A2 hp€200.68
D
XTMC9A01E
3208V AC-60 Hz--9A2 hp€205.96
F
XTMC9A10C
3415/480V AC1.77"50/60 Hz--9A2 hp€200.68
F
XTMC9A10B
3-2"-8.8A-9A2 hp€200.68
D
XTMC9A01A
3110/120V AC2"50/60 Hz8.8A-9A2 hp€205.96
F
XTMC9A10E
3208V AC2"60 Hz8.8A-9A2 hp€182.45
G
XTMC9A01C
3415-480V AC2"50/60 Hz8.8A1/2, 1, 1 1/2/ 2, 3, 5, 5 hp (1/3 Phase @ 115, 200, 230/200, 230, 460, 575V)9A2 hp€205.96
B
XTMC6A10TD
324V DC1.77"50/60 Hz6.6A-6A1 1/2 hp€196.02
F
XTMC9A10TD
3-1.77"-8.8A-9A2 hp€234.17
B
XTMC6A10C
3415/480V AC2"50/60 Hz6.6A-6A1 1/2 hp€138.66
B
XTMC6A10B
3-2"-6.6A-6A1 1/2 hp€138.66
F
XTMC9A10T
324V AC2"50/60 Hz8.8A-9A2 hp€200.68
D
XTMC9A01B
3220/240V AC1.77"50/60 Hz--9A2 hp€205.96
D
XTMC9A01TD
324V DC1.77"50/60 Hz8.8A-9A2 hp€271.47
H
XTMF9A00B
4220/240V AC2"50/60 Hz--9A2 hp€197.08
H
XTMF9A00TD
424V DC-50/60 Hz--9A2 hp€241.92
H
XTMF9A00T
424V AC2"50/60 Hz8.8A-9A2 hp€197.08
H
XTMF9A00C
4415/480V AC-50/60 Hz--9A2 hp€197.08
H
XTMF9A00A
4110/120V AC-50/60 Hz--9A2 hp€197.08

Features

  • Eaton mini contactors have screw terminals for easy installation / removal of circuit wires.
  • They have a continuous ampere rating of 40A and a frequency rating of 60 Hz.
  • These three-pole units have NC configuration.

Standards and Approvals

  • UL
  • CSA
  • IEC, EN, CE, RoHS (selected models)

Frequently Asked Questions

What is the difference between AC and DC contactors?

DC contactor has a maximum operating frequency of 1200 times per hour, while AC contactors have a maximum operating frequency of 600 times per hour.

What is the full voltage non-reversing method?

When the controller's single contactor actuates, FVNR allows the full line voltage to be applied to the motor. With an FVNR motor controller, the position of the line phases is fixed and the motor can only be operated in one rotational direction.

What is the difference between a relay and a contactor?

Relays control contacts of an electrical circuit due to a change of parameters or conditions in the same circuit or any other associated circuit. Contactors, on the other hand, are used to interrupt or establish connections in an electrical circuit repeatedly under different conditions.

We are here to help!

Looking for a part not listed here?