EATON XT Series IEC Mini Contactors


Eaton XT-Series mini contactors are compact relay units that switch on / off an electric circuit. These full voltage non-reversing units are useful in compact machines, conveyors and PCB boards where saving space is a major concern.

Filter
StyleModelNumber Of PolesMain Power Pole Contact FormAuxiliary Contacts IncludedNominal Coil Voltage @ 60hzIncludes Auxiliary ContactsHeightMechanical Operating DurabilityHp @ 1 Phase - 120vPrice
A
XTMC6A01B
33NO1NC240V ACYes1.77"100000001/4 hp€156.65
B
XTMC9A01A
33NO1NC120V ACYes2"100000001/2 hp€205.96
C
XTMC9A10TD
3---Yes1.77"-1/2 hp€234.17
D
XTMC6A10C
33NO1NO480V ACYes2"100000001/4 hp€138.66
D
XTMC6A10B
3---Yes2"-1/4 hp€138.66
C
XTMC9A10T
33NO1NO24V ACYes2"100000001/2 hp€200.68
B
XTMC9A01B
33NO1NC240V ACYes1.77"100000001/2 hp€205.96
B
XTMC9A01TD
33NO1NC24V DCYes1.77"200000001/2 hp€271.47
C
XTMC9A10C
33NO1NO480V ACYes1.77"100000001/2 hp€200.68
B
XTMC9A01T
33NO1NC24V ACYes2"100000001/2 hp€205.96
E
XTMC6A01TD
33NO1NC24V DCYes2"200000001/4 hp€201.44
E
XTMC6A01A
33NO1NC120V ACYes2"100000001/4 hp€156.65
D
XTMC6A10E
33NO1NO208V ACYes1.77"100000001/4 hp€138.66
C
XTMC9A10A
3---Yes2 1/2"-1/2 hp€200.68
B
XTMC9A01E
33NO1NC208V ACYes-10000000-€205.96
C
XTMC9A10E
33NO1NO208V ACYes2"100000001/2 hp€182.45
F
XTMC9A01C
33NO1NC480V ACYes2"10000000-€205.96
G
XTMC6A10T
33NO1NO24V ACYes2 1/2"10000000-€138.66
C
XTMC9A10B
3---Yes2"-1/2 hp€200.68
D
XTMC6A10R
33NO1NO12V ACYes1.77"100000001/4 hp€137.15
G
XTMC6A10A
33NO1NO120V ACYes2 1/2"10000000-€138.66
A
XTMC6A01T
33NO1NC24V ACYes1.77"100000001/4 hp€156.65
D
XTMC6A10TD
33NO1NO24V DCYes1.77"200000001/4 hp€196.02
H
XTMF9A00B
44NONone240V ACNo2"100000001/2 hp€197.08
H
XTMF9A00TD
44NONone24V DCNo-10000000-€241.92
H
XTMF9A00C
44NONone480V ACNo-10000000-€197.08
H
XTMF9A00A
44NONone120V ACNo-10000000-€197.08
H
XTMF9A00T
44NONone24V ACNo2"100000001/2 hp€197.08

Features

  • Eaton mini contactors have screw terminals for easy installation / removal of circuit wires.
  • They have a continuous ampere rating of 40A and a frequency rating of 60 Hz.
  • These three-pole units have NC configuration.

Standards and Approvals

  • UL
  • CSA
  • IEC, EN, CE, RoHS (selected models)

Frequently Asked Questions

What is the difference between AC and DC contactors?

DC contactor has a maximum operating frequency of 1200 times per hour, while AC contactors have a maximum operating frequency of 600 times per hour.

What is the full voltage non-reversing method?

When the controller's single contactor actuates, FVNR allows the full line voltage to be applied to the motor. With an FVNR motor controller, the position of the line phases is fixed and the motor can only be operated in one rotational direction.

What is the difference between a relay and a contactor?

Relays control contacts of an electrical circuit due to a change of parameters or conditions in the same circuit or any other associated circuit. Contactors, on the other hand, are used to interrupt or establish connections in an electrical circuit repeatedly under different conditions.

We are here to help!

Looking for a part not listed here?