EATON ETR-5000 Series Transformer Relays
Eaton ETR-5000 Series transformer relays provide protection and control for power transformers. They are used in industrial facilities and electric utility substations. These relays can be used to monitor the temperature of the transformer and trip the breaker if it exceeds a certain threshold.
Filter
| Style | Model | Mounting Type | Analog Inputs | Voltage Sensing Inputs | Analog Outputs | Modbus/dnp3 Rtu | Profibus-dp | Height | Type | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | ETR-5000-2B0EB0 | - | - | - | - | - | - | 8.7" | - | €29,170.98 | |
| A | ETR-5000-2B2FA0 | - | - | - | - | - | - | 8.7" | - | - | RFQ
|
| A | ETR-5000-2A0CB1 | - | - | - | - | - | - | 8.7" | - | €27,490.27 | |
| A | ETR-5000-2B1FA0 | - | - | - | - | - | - | 8.7" | - | €26,554.97 | |
| A | ETR-5000-2A0FB1 | Projection | 0 | 1 | 0 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €27,841.03 | |
| A | ETR-5000-2B2DA1 | Projection | 2 | 1 | 2 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €27,490.27 | |
| A | ETR-5000-2B2EB1 | Projection | 2 | 1 | 2 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | €29,317.11 | |
| A | ETR-5000-2B2GB1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B3EA1 | Projection | 2 | 1 | 2 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | €27,241.86 | |
| A | ETR-5000-2B3DA1 | Projection | 2 | 1 | 2 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B3GB1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B3GA1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | €26,248.03 | |
| A | ETR-5000-2B3KA1 | Projection | 2 | 1 | 2 | - | - | 8.7" | Transformer Relay | €29,331.73 | |
| A | ETR-5000-2B3IA1 | Projection | 2 | 1 | - | Over RS-485 | - | 8.7" | Transformer Relay | - | RFQ
|
| B | ETR-4000-2A0LB1 | Projection | 0 | 0 | 0 | - | - | - | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B1KB1 | Projection | 2 | 1 | 2 | - | - | 8.7" | Transformer Relay | €31,436.26 | |
| A | ETR-5000-2A1HA1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €27,943.33 | |
| A | ETR-5000-2A1KA1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €28,396.40 | |
| A | ETR-5000-2A1IA1 | Projection | 0 | 1 | 0 | Over RS-485 | - | 8.7" | Transformer Relay | €25,619.63 | |
| A | ETR-5000-2A2DB1 | Projection | 0 | 1 | 0 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €28,644.86 | |
| A | ETR-5000-2A2DA1 | Projection | 0 | 1 | 0 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €26,540.33 | |
| A | ETR-5000-2A2KA1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €28,396.40 | |
| A | ETR-5000-2A3EA1 | Projection | 0 | 1 | 0 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2A3CB1 | Projection | 0 | 1 | 0 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | €27,490.27 | |
| A | ETR-5000-2A3IB1 | Projection | - | 1 | 0 | Over RS-485 | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B0DA1 | Projection | 2 | 1 | 2 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €27,490.27 | |
| A | ETR-5000-2B0EA1 | Projection | 2 | 1 | 2 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | €27,241.86 | |
| A | ETR-5000-2A0HA1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B1IA1 | Projection | 2 | 1 | 2 | - | - | 8.7" | Transformer Relay | €26,584.18 | |
| A | ETR-5000-2B1GB1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | €28,352.57 | |
| A | ETR-5000-2A1IB1 | Projection | 0 | 1 | 0 | Over RS-485 | - | 8.7" | Transformer Relay | €27,724.12 | |
| A | ETR-5000-2A1KB1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €30,486.30 | |
| A | ETR-5000-2A2KB1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €30,486.30 | |
| A | ETR-5000-2A3CA1 | Projection | 0 | 1 | 0 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2A3FA1 | Projection | 0 | 1 | 0 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €25,751.16 | |
| A | ETR-5000-2B1BB1 | Projection | 2 | 1 | 2 | Over RS-485 | - | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B0GA1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | €26,248.03 | |
| A | ETR-5000-2B1CA1 | Projection | 2 | 1 | 2 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | €26,335.70 | |
| A | ETR-5000-2A0EA1 | Projection | 0 | 1 | 0 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | €26,262.65 | |
| A | ETR-5000-2A0KA1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €28,396.40 | |
| A | ETR-5000-2A1CA1 | Projection | 0 | 1 | 0 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | €25,385.77 | |
| A | ETR-5000-2A1BB1 | Projection | 0 | 1 | 0 | Over RS-485 | - | 8.7" | Transformer Relay | €27,066.44 | |
| A | ETR-5000-2A1HB1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €30,047.86 | |
| A | ETR-5000-2B0IB1 | Projection | 2 | 1 | 2 | Over RS-485 | - | 8.7" | Transformer Relay | €28,674.05 | |
| A | ETR-5000-2A2CB1 | Projection | 0 | 1 | 0 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | €27,490.27 | |
| A | ETR-5000-2A2FA1 | Projection | 0 | 1 | 0 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €25,751.16 | |
| A | ETR-5000-2A2IA1 | Projection | 0 | 1 | 0 | Over RS-485 | - | 8.7" | Transformer Relay | €25,619.63 | |
| A | ETR-5000-2A3DA1 | Projection | 0 | 1 | 0 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €26,540.33 | |
| A | ETR-5000-2A3FB1 | Projection | 0 | 1 | 0 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €27,841.03 | |
| A | ETR-5000-2B0BB1 | Projection | 2 | 1 | 2 | Over RS-485 | - | 8.7" | Transformer Relay | €27,987.21 | |
| A | ETR-5000-2A3LB1 | Projection | 0 | 1 | 0 | - | - | 8.7" | Transformer Relay | €28,104.08 | |
| A | ETR-5000-2B0DB1 | Projection | 2 | 1 | 2 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | - | RFQ
|
| A | ETR-5000-2B0KA1 | Projection | 2 | 1 | 2 | - | - | 8.7" | Transformer Relay | €29,331.73 | |
| A | ETR-5000-2B0LB1 | Projection | 2 | 1 | 2 | - | - | 8.7" | Transformer Relay | €29,039.47 | |
| A | ETR-5000-2B1DB1 | Projection | 2 | 1 | 2 | - | Over Fiber Optic ST | 8.7" | Transformer Relay | €29,594.82 | |
| A | ETR-5000-2B0GB1 | Projection | 2 | 1 | 2 | D-Sub / RS-485 | - | 8.7" | Transformer Relay | €28,352.57 | |
| A | ETR-5000-2B1FA1 | Projection | 2 | 1 | 2 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €26,701.06 | |
| A | ETR-5000-2B1EA1 | Projection | 2 | 1 | 2 | - | Over D-Sub/RS-485 | 8.7" | Transformer Relay | €27,241.86 | |
| A | ETR-5000-2B2IA1 | Projection | 2 | 1 | 2 | Over RS-485 | - | 8.7" | Transformer Relay | €26,584.18 | |
| A | ETR-5000-2B0CA1 | Projection | 2 | 1 | 2 | Over Ethernet RJ-45 | - | 8.7" | Transformer Relay | €26,335.70 | |
| A | ETR-5000-2B0FB1 | Projection | 2 | 1 | 2 | Over Fiber Optic ST | - | 8.7" | Transformer Relay | €28,790.99 |
Features
- Eaton ETR-5000 Series transformer relays feature a universal resistance temperature detector (URTD) module for safe operation within temperature limits, ensuring long service life.
- They have breaker wear & general counter functions that continuously monitor the operation of the relay and provide data for troubleshooting and maintenance.
- These transformer relays' waveform recorders and fault recorders can store up to 7200 cycles and 20 events, respectively.
- They have RIG-B time synchronisation function for high-speed fault detection and fault detection.
Frequently Asked Questions
How to resolve the issue when the event recorder is permanently logging new events on Eaton ETR-5000 Series transformer relays?
- Examine the event recorder to determine which protection function is generating the events.
- Review the configuration of the protection function and adjust it accordingly, if needed. For instance, if the df/dt (ROCOF) protection function is generating frequent alarms due to overly sensitive settings, modify the function's settings.
How do I select an appropriate Eaton ETR-5000 Series relay for my transformer?
The selection of the appropriate Eaton ETR-5000 Series relay depends on various factors, such as the type & size of the transformer, the required protection functions and the communication requirements.
Do Eaton ETR-5000 Series transformer relays monitor trips in circuits?
Yes, they feature trip circuit monitoring for reliable detection of faults in the circuit.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- VIKING AIR TOOLS
- WALDMANN
- MCKINNEY
- VERSILON
- LED Floodlights
- Belt Driven Exhaust Fans
- Hex Standoffs
- Handrail Brackets
- Cutting Attachments
- AKRO-MILS 30288 Akrobins Super Size Bins
- NORTH BY HONEYWELL NF11X Northflex Nylon Gloves, Red
- TEMPCO CRT Series E-Mitters
- MUELLER INDUSTRIES 1601-C Chexter Check Valves
- GLOBE SCIENTIFIC Wash Bottles, Wide Mouth, LDPE, 1000 ml Capacity
- STANLEY Tape Measures
- DIXON Ezlink Replacement Gasket
- APOLLO VALVES Tailpieces
- MERIT BRASS 2004 Pipe Nipples
- PARKER 4MA Series Tie Rod Pneumatic Cylinders, 2 Inch Bore, LipSeals And Magnetic Ring

