EATON ECN16 Class Combination Reversing Starters
Eaton ECN16 Class combination reversing starters are used in HVAC systems, lighting, transformers and generators to control the direction of motor rotation and to protect against current overloads & short circuits.
Filter
| Style | Model | Height | Frequency | Coil Voltage | Nema Enclosure Rating | Phase | Notes | Price | |
|---|---|---|---|---|---|---|---|---|---|
| A | ECN1602CAA | 11" | - | - | - | - | - | €3,525.75 | |
| B | ECN1611AAC-E3 | 23.06" | 50-60 Hz | 110-120V AC | NEMA 1 | 3 | - | €3,678.96 | |
| A | ECN1618AAA-E11 | 24.98" | 60 Hz | 208V AC | NEMA 4X | 3 | - | €3,710.80 | |
| A | ECN1612AAA-E3 | 24.98" | 60 Hz | 208V AC | - | 3 | Oversize Enclosure | €4,439.02 |
Features
- They have NEMA-rated enclosures to prevent dirt, dust and contaminations.
- These starters are designed to control motors ranging in size from 1/3 to 15 horsepower.
- They feature a mechanical interlock to prevent both the contactors from being closed at the same time and causing a short circuit.
- These starters come with auxiliary contacts for remote indication of the starter's status and use in control circuits.
Standards and Approvals
- UL
Frequently Asked Questions
How do I clean Eaton ECN16 Class combination reversing starters?
- Turn off the power supply to the starter before cleaning.
- Remove the cover of the combination starter.
- Use compressed air to blow off dust and debris.
- Wipe the internal components with a soft cloth.
- Use a cleaning solution for stubborn dirt or grime.
- Reassemble the starter following the manufacturer's instructions.
How to install these starters?
- Select an enclosure that meets application requirements and provides adequate environmental protection.
- Mount the enclosures in a suitable location with proper clearance.
- Connect the three-phase AC power supply to the line terminals on the contactor enclosure.
- Connect the motor leads to the load terminals on the contactor enclosure.
- Connect the control circuit wires to the auxiliary contacts on the contactor and overload relay enclosures.
- Connect the reversing contacts between the two contactor enclosures.
- Test the starter to ensure proper operation and overload protection.
- Label the starter with appropriate markings to identify terminals and control devices.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- PEERLESS HARDWARE
- PAN AMERICAN TOOL
- TIGER TRACK
- QUICK DAM
- Sensor Cordsets
- Positioning and Restraint Lanyards
- Hazardous Location Motors
- Heat Stress Monitors
- Hazardous Location Safety and Disconnect Switches
- 3M 6000 Series Mold Remediation Respirator Kits
- DESTACO 323 Series Pull Action Latch Clamps
- CHICAGO PNEUMATIC Angle Wheel Grinders, Bevel Gear
- MUELLER INDUSTRIES 72HHH3HW Sure Check Double Disc Check Valves
- GLOBE SCIENTIFIC Translucent Snap Caps, For 12/13 mm Tubes
- KISSLER & CO Water Supply Stop
- MASTER APPLIANCE Elements
- ARCHON INDUSTRIES Garden Hose Nozzles
- TEKTON Long Bit Sockets, Torx
- DIXON Short Shank GHT Complete Couplings With Round Nut