EATON Definite Purpose Contactors, Two Pole


Eaton definite-purpose contactors are designed to switch high-current loads in motors, heating and cooling systems, lighting and other electrical equipment. They feature an open enclosure to surround and protect the internal components without a cover or lid.

Filter
StyleModelProduct HeightProduct WidthAmpsCoil VoltageTypeNo. Of PolesFrequencyModelPrice
A
C25BNF220B
1.97"2 8/25"20A208-240V ACNon-Reversing-50/60 HzContactor€117.77
B
C25BNF220T
1.97"2 8/25"20A24V ACNon-Reversing-50/60 HzContactor€117.77
B
C25BNF225H
1.97"2 8/25"25A277V ACNon-Reversing-60 HzContactor€131.10
C
C25DND230T
2 1/2"2 2/5"30A24V ACNon-Reversing2, 350/60 HzContactor€165.94
C
C25DND240A-GL
2 1/2"2 2/5"40A110-120V AC-2, 350/60 HzContactor€205.52
C
C25DND215T-GL-84
2 1/2"2 2/5"15A24V ACNon-Reversing2, 3-Contactor€137.75
C
C25DND240T-84
3 3/4"2 2/5"40A24V ACNon-Reversing2, 350/60 HzContactor€178.85
C
C25DNA250L
3 3/4"2 2/5"50A380-415V ACNon-Reversing2, 3-Contactor€494.92
C
C25DNF240AC
3 3/4"2 2/5"40A208-240V ACNon-Reversing2, 3-Contactor€238.87
C
C25DNF2401W
3 3/4"2 2/5"40A208-240V ACNon-Reversing2, 3-Contactor€257.72
C
C25DNF240D-GL
3 3/4"2 2/5"40A24V ACNon-Reversing2, 3-Contactor€198.87
C
C25DNF240T-GL
3 3/4"2 2/5"50A24V DCNon-Reversing2, 3-Contactor€205.52
C
C25DNF2501R-GL
3 3/4"2 2/5"50A110-120V ACNon-Reversing2, 3-Contactor€614.31
C
C25DNA250A-GL
3 3/4"2 2/5"15-50A110-120V ACNon-Reversing2-Contactor€494.92
C
C25DNA250D-GL
3 3/4"2 2/5"15-50A550-600V ACNon-Reversing2, 3-Contactor€494.92
C
C25DNF230R-GL
3 3/4"2 2/5"40A12V DCNon-Reversing2, 350/60 HzContactor€171.09
C
C25DND230C
3 3/4"2 2/5"30A440-480V ACNon-Reversing2, 350/60 HzContactor€108.23
C
C25DND2401W-GL
3 3/4"2 2/5"15-50A48V DCNon-Reversing2, 3-Contactor€257.72
C
C25DND240C
3 3/4"2 2/5"40A440-480V ACNon-Reversing2, 350/60 HzContactor€178.85
C
C25DND240H-GL
3 3/4"2 2/5"15-50A277V ACNon-Reversing2, 360 HzContactor€178.85
C
C25DNE215D-GL
3 3/4"2 2/5"15-50A120V DCNon-Reversing2, 3-Contactor€135.53
C
C25DNE2251R-GL
3 3/4"2 2/5"15-50A440-480V ACNon-Reversing2, 350/60 HzContactor€232.17
C
C25DNF230H-GL
3 3/4"2 2/5"40A120V DCNon-Reversing2, 360 HzContactor€168.87
C
C25DNF225T-GL
3 3/4"2 2/5"30A110-120V AC-2, 350/60 HzContactor€173.33
C
C25DNE215L-GL
3 3/4"2 2/5"15-50A24V DCNon-Reversing2, 3-Contactor€135.53
C
C25DNE2501W-GL
3 3/4"2 2/5"50A440-480V ACNon-Reversing2, 350/60 HzContactor€614.31
C
C25DNE225T
3 3/4"2 2/5"25A24V ACNon-Reversing2, 350/60 HzContactor€137.75
C
C25DNE2301T-GL
3 3/4"2 2/5"15-50A550-600V ACNon-Reversing2, 350 HzContactor€246.63
C
C25DNE230A-GL
3 3/4"2 2/5"15-50A380-415V ACNon-Reversing2, 350 HzContactor€168.87
C
C25DNE2401A-GL
3 3/4"2 2/5"40A48V DCNon-Reversing2, 3-Contactor€274.39
C
C25DNE2401A
3 3/4"2 2/5"40A120V DCNon-Reversing2, 3-Contactor€274.39
C
C25DNE240A
3 3/4"2 2/5"40A110-120V ACNon-Reversing2, 350/60 HzContactor€178.85
C
C25DNE2501T
3 3/4"2 2/5"50A24V DCNon-Reversing2, 350/60 HzContactor€614.31
C
C25DNF225R-GL
3 3/4"2 2/5"15-50A-Non-Reversing2, 3-Contactor€156.66
C
C25DNE250A
3 3/4"2 2/5"50A110-120V ACNon-Reversing2, 350/60 HzContactor€494.92
C
C25DNE250T-GL
3 3/4"2 2/5"15-50A110-120V ACNon-Reversing2, 350/60 HzContactor€494.92
C
C25DNE250L-GL
3 3/4"2 2/5"15-50A-Non-Reversing2, 3-Contactor€494.92
C
C25DNF2151W-GL
3 3/4"2 2/5"15-50A550-600V ACNon-Reversing2, 350 HzContactor€223.30
C
C25DNE225T-GL
3 3/4"2 2/5"25A110-120V ACNon-Reversing2, 350/60 HzContactor€158.88
C
C25DNF2251R-GL
3 3/4"2 2/5"15-50A12V DCNon-Reversing2, 3-Contactor€236.63
C
C25DNF215T-GL
3 3/4"2 2/5"15-50A24V ACNon-Reversing2, 350/60 HzContactor€139.99
D
C25DNJ250DJ
3 3/4"2 2/5"50A550-600V ACNon-Reversing2, 3-Contactor€600.49
C
C25DNE225B-GL
3 3/4"2 2/5"15-50A12V ACNon-Reversing2, 350/60 HzContactor€151.07
D
C25DNY73
3 3/4"2 2/5"15-50A24V ACNon-Reversing2, 350/60 HzContactor€211.86
C
C25DNF2501T
3 3/4"2 2/5"50A110-120V ACNon-Reversing2, 3-Contactor€614.31
C
C25DNF250C-GL
3 3/4"2 2/5"50A277V ACNon-Reversing2, 360 HzContactor€494.92
D
C25DNM240B9-GL
3 3/4"2 2/5"15-50A208-240V ACNon-Reversing2, 3-Contactor€233.28
D
C25DNM250C-GL
3 3/4"2 2/5"15-50A440-480V ACNon-Reversing2, 3-Contactor€494.92
D
C25DNY46T
3 3/4"2 2/5"15-50A110-120V ACNon-Reversing2, 350/60 HzContactor€178.99
D
C25DNY7B
3 3/4"2 2/5"15-50A208-240V ACNon-Reversing2, 350-60 HzContactor€213.31
D
C25DNY7A
3 3/4"2 2/5"15-50A110-120V ACNon-Reversing2, 350/60 HzContactor€213.31
E
C25DNF240A
3 3/4"2 2/5"40A208-240V ACNon-Reversing2, 3-Contactor€181.78
D
C25DRB350A
3 3/4"2 2/5"50A110-120V ACNon-Reversing2, 350/60 HzContactor€344.38
D
C25DRC215B-GL
3 3/4"2 2/5"15-50A208-240V ACNon-Reversing2, 350-60 HzContactor€114.44
D
C25DRC215A-GL
3 3/4"2 2/5"15-50A208-240V ACNon-Reversing2, 350-60 HzContactor€114.44
D
C25DRC2251T-GL
3 3/4"2 2/5"15-50A110-120V ACNon-Reversing2, 350/60 HzContactor€230.18
D
C25DRC225A-GL
3 3/4"2 2/5"15-50A208-240V ACNon-Reversing2, 350-60 HzContactor€128.88
D
C25DRE250B
3 3/4"2 2/5"50A208-240V ACNon-Reversing2, 350/60 HzContactor€472.43
D
C25DRE250T-GL
3 3/4"2 2/5"15-50A24V ACNon-Reversing2, 350/60 HzContactor€470.71
C
C25DNF240T
3 3/4"2 2/5"40A120V DCNon-Reversing2, 3-Contactor€181.78
C
C25DNF240BA-GL
3 3/4"2 2/5"40A277V ACNon-Reversing2, 3-Contactor€246.63

Working Mechanism

  • The double-pole definite-purpose contactor uses an electromagnet to control the flow of current.
  • When a current is applied to the electromagnet, it creates a magnetic field that attracts an armature.
  • This forces the armature to close the electrical contacts, allowing the current to flow to the load and turning it on.
  • When the coil is de-energised, the magnetic field collapses, causing the armature to return to its original position, thereby opening the contacts and turning off the load.

Frequently Asked Questions

What is the purpose of quick-connect terminals?

Quick-connect terminals allow fast and easy connection and disconnection of wires. They typically consist of a metal blade inserted into a socket and can be easily removed by pulling or pushing the release tab.

How do I size a contactor for a specific operation?

To determine the size of the connector, users must select a contactor with a current rating equal to or greater than the full-load current of the motor or other load and with a voltage rating that matches the voltage of the power source.

How to install definite-purpose contactors?

  • Turn off the power to the equipment where the contactor needs to be installed.
  • Mount the contractor securely to a location where it is not exposed to excessive heat, moisture or vibration.
  • Connect the line voltage wire to the side of the contactor.
  • Connect the load wires to the bottom terminals of the contactor.

We are here to help!

Looking for a part not listed here?