PLAST-O-MATIC Window Sight Flow Indicators
Used for measuring the liquid flow rates, through a closed system, at a maximum line pressure of 200 psi. Feature sensors with switches to initiate the alarm, activate other equipment or shut the system. Integrated with a PVC constructed screen for quantitative readout
Used for measuring the liquid flow rates, through a closed system, at a maximum line pressure of 200 psi. Feature sensors with switches to initiate the alarm, activate other equipment or shut the system. Integrated with a PVC constructed screen for quantitative readout
Plast-O-Matic variable area flow indicators indicate liquid flow rates from low flows of 0 - 1 GPM even when used at high line pressures. These flow indicators feature sensors with switches to initiate the alarm, activate other equipment or shut the system.
| Style | Model | MPN | Price | |
|---|---|---|---|---|
| A | FIGS025V-CP-2.5-A-1 | €471.24 | RFQ | |
| A | FIGS025V-CP-2.5-A-2 | €471.24 | RFQ | |
| A | FIGS025V-CP-2.5-B-1 | €471.24 | RFQ | |
| A | FIGS025V-CP-2.5-B-2 | €471.24 | RFQ | |
| A | FIGS025V-CP-2.5-C-1 | €471.24 | RFQ | |
| A | FIGS025V-CP-2.5-C-2 | €471.24 | RFQ | |
| A | FIGS025V-PV-2.5-A-1 | €441.00 | RFQ | |
| A | FIGS025V-PV-2.5-A-2 | €441.00 | RFQ | |
| A | FIGS025V-PV-2.5-B-1 | €441.00 | RFQ | |
| A | FIGS025V-PV-2.5-B-2 | €441.00 | RFQ | |
| A | FIGS025V-PV-2.5-C-1 | €441.00 | RFQ | |
| A | FIGS025V-PV-2.5-C-2 | €441.00 | RFQ | |
| A | FIGS050V-CP-2.5-A-5 | €534.24 | RFQ | |
| A | FIGS050V-CP-2.5-A-10 | €534.24 | RFQ | |
| A | FIGS050V-CP-2.5-B-5 | €534.24 | RFQ | |
| A | FIGS050V-CP-2.5-B-10 | €534.24 | RFQ | |
| A | FIGS050V-CP-2.5-C-5 | €534.24 | RFQ | |
| A | FIGS050V-CP-2.5-C-10 | €534.24 | RFQ | |
| A | FIGS050V-PV-2.5-A-5 | €504.00 | RFQ | |
| A | FIGS050V-PV-2.5-A-10 | €504.00 | RFQ | |
| A | FIGS050V-PV-2.5-B-5 | €504.00 | RFQ | |
| A | FIGS050V-PV-2.5-B-10 | €504.00 | RFQ | |
| A | FIGS050V-PV-2.5-C-5 | €504.00 | RFQ | |
| A | FIGS050V-PV-2.5-C-10 | €504.00 | RFQ |
| Style | Model | MPN | Price | |
|---|---|---|---|---|
| A | FIG025V-CP-2.5-1 | €399.42 | RFQ | |
| A | FIG025V-CP-2.5-2 | €399.42 | RFQ | |
| A | FIG025V-PV-2.5-1 | €366.66 | RFQ | |
| A | FIG025V-PV-2.5-2 | €366.66 | RFQ | |
| A | FIG050V-CP-2.5-5 | €399.42 | RFQ | |
| A | FIG050V-CP-2.5-10 | €399.42 | RFQ | |
| A | FIG050V-PV-2.5-5 | €366.66 | RFQ | |
| A | FIG050V-PV-2.5-10 | €366.66 | RFQ |
Features
- Plast-O-Matic variable area flow indicators are used for measuring the liquid flow rates, through a closed system, at a maximum line pressure of 200 psi.
- These flow indicators are incorporated with a PVC-constructed screen for quantitative readout of variable area flow.
- They feature corrosion-resistant thermoplastic connections (PVC or CPVC) and EPDM or FKM elastomers.
- These Plast-O-Matic flow indicators come with 1/4 or 1/2 Inch FNPT connections.
Working Mechanism
- These devices rely on the difference between two pressures to function (delta-P).
- As flow is established through the variable orifice that is created between the spring-biased metering cone and the end cap that the cone rests in, developing delta-P.
- The cone can move linearly in relation to the delta-P due to the variable orifice. A follower magnet is rotated by a magnet on the metering cone which moves together with the cone in a chamber next to the fluid cavity.
- To deliver gauge readings proportional to flow, the gauge pointer is positioned at the end of the rotary magnet shaft and spins with the magnet.
- Between the flow chamber and the rotary chamber, there are no mechanical seals. It is attained by coupling forces between two neighbouring magnets through a solid wall.
Frequently Asked Questions
How does a variable area flowmeter operate?
Variable area flowmeters are highly adaptable flow measurement tools that can be used with a variety of liquids, gases, and steam. They work on the basis of the variable area principle, whereby a flowing fluid moves a float, piston or vane in order to provide a larger area for the fluid to travel through.
Why is a rotameter known as a variable area flowmeter?
The variable-area flowmeter is called a rotameter because the float rotates as the flow passes it. The spinning float is an obvious signal that fluid is flowing.
What is a rotameter?
A flow meter that monitors the volumetric flow of liquids and gases is called a rotameter (variable area flow metre).
Popular Search Queries
Explore More
- DIVERSIFIED PLASTICS
- KEYSHAFT
- TROEMNER
- Creepers and Creeper Seats
- Food Hoses
- Machine Guards
- Battery Specialty Tools
- Caulk Guns
- E JAMES & CO Rubber Strip, General Purpose, 70A
- UEI TEST INSTRUMENTS Digital Pocket Thermometers
- VERMONT GAGE NoGo Standard Thread Plug Gages, 7/8-16 Un
- DAYTON Shutters
- COXREELS EZ-T Series Spring Driven Hose Reels
- MUELLER INDUSTRIES 125 Carbon Steel Y Strainers
- ELVEX Full Magnifying Protective Eyewears
- ANSELL 11-927 Hyflex Medium Duty Oil Repellent Cut Resistant Gloves
- CONDOR Leather Coated Cut Resistant Gloves, Cut Level A4