DAYTON Shutters
Shutters
| Style | Model | Fits Fan Dia. | Overall Height | Overall Width | Blade Material | Frame Material | Flange Width | Frame Depth | Max. Velocity | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | GGS_47519 | €267.57 | |||||||||
| B | GGS_47521 | €351.66 | |||||||||
| C | 502GST16 | €109.95 | |||||||||
| D | GGS_47520 | €308.94 | |||||||||
| E | 411873A | €98.16 | |||||||||
| E | 317241G | €1,717.92 | |||||||||
| F | GGS_47523 | €237.66 | |||||||||
| G | 502GST12 | €102.33 | |||||||||
| H | GGS_47522 | €403.02 | |||||||||
| I | 502GST8 | €78.26 | |||||||||
| E | WAG540007A | €1,355.49 | |||||||||
| J | 502GST10 | €82.62 | |||||||||
| K | GGS_47524 | €448.56 | |||||||||
| L | 556GST30 | €209.60 | |||||||||
| M | SA36SW | €288.67 | |||||||||
| M | SA48SW | €392.67 |
Fan Shutters
Dayton fan shutters are used with belt or direct driven exhaust fans for preventing air backflow for building ventilation operations. These shutters are ideal for chemical plants, poultry processing & refining facilities and feature heavy duty fibreglass / aluminium blades for protection against harsh environments. They have a pre punched galvanised steel / aluminium / fibreglass frame for ensuring long term durability and ease of installation. Selected models come with galvanised reinforcement strips on blades for providing counter balancing during operation. Choose from a broad range of these fan shutters, available in horizontal & vertical mounting designs.
Dayton fan shutters are used with belt or direct driven exhaust fans for preventing air backflow for building ventilation operations. These shutters are ideal for chemical plants, poultry processing & refining facilities and feature heavy duty fibreglass / aluminium blades for protection against harsh environments. They have a pre punched galvanised steel / aluminium / fibreglass frame for ensuring long term durability and ease of installation. Selected models come with galvanised reinforcement strips on blades for providing counter balancing during operation. Choose from a broad range of these fan shutters, available in horizontal & vertical mounting designs.
| Style | Model | Type | Blade Material | Mounting Location | Frame Depth | Max. Velocity | Number Of Panels | Opening Required | Fits Fan Dia. | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | 1C210 | €329.27 | |||||||||
| A | 1C211 | €443.16 | |||||||||
| A | 1C209 | €287.25 | |||||||||
| A | 3C116 | €689.43 | |||||||||
| A | 3C115 | €590.74 | |||||||||
| B | 1C055 | €170.97 | |||||||||
| C | 4YN18 | €392.34 | |||||||||
| D | 4C228 | €355.31 | |||||||||
| B | 4C521 | €309.37 | |||||||||
| E | 4YN17 | €267.77 | |||||||||
| F | 4YN20 | €141.23 | |||||||||
| C | 4YN19 | €682.19 | |||||||||
| D | 4C224 | €283.35 | |||||||||
| G | 5C210 | €148.96 | |||||||||
| G | 5C211 | €164.30 | |||||||||
| G | 5C212 | €190.10 | |||||||||
| G | 5C213 | €207.00 | |||||||||
| G | 5C214 | €212.40 | |||||||||
| G | 5C215 | €267.18 | |||||||||
| D | 4C225 | €280.54 | |||||||||
| D | 3C243 | €631.48 | |||||||||
| H | 3C512 | €225.36 | |||||||||
| H | 3C511 | €210.53 | |||||||||
| H | 3C510 | €223.25 | |||||||||
| B | 2C526 | €79.26 |
Ceiling Shutter
Dayton ceiling shutters are placed securely in the ceiling opening just below the whole house fan units. These shutters feature an aluminium flanged frame and white-painted blades with a galvanised reinforcement strip for added strength and counter balancing efficiency. They utilise tie rods, on both ends of the blades, for uniform opening when the fan is ventilating the building. These units are recommended for horizontal-mount exhausts and are available in 26, 30.75, 32, 35, 36, 37.75 and 44 inch lengths.
Dayton ceiling shutters are placed securely in the ceiling opening just below the whole house fan units. These shutters feature an aluminium flanged frame and white-painted blades with a galvanised reinforcement strip for added strength and counter balancing efficiency. They utilise tie rods, on both ends of the blades, for uniform opening when the fan is ventilating the building. These units are recommended for horizontal-mount exhausts and are available in 26, 30.75, 32, 35, 36, 37.75 and 44 inch lengths.
Ceiling Truss Shutter
Dayton ceiling shutters are sung fit onto the ceiling opening for use with whole house fans. These shutters feature aluminium blades with a delt seal on the leading edge for quiet operation and have tie rods on each end to assure a uniform opening when positive air pressure is applied to properly ventilate the facility. They have galvanised steel construction and come with pre-punched mounting holes for ease in installation. Choose from an extensive range of these ceiling truss shutters, available in 32, 35, 42 and 43 inch lengths.
Dayton ceiling shutters are sung fit onto the ceiling opening for use with whole house fans. These shutters feature aluminium blades with a delt seal on the leading edge for quiet operation and have tie rods on each end to assure a uniform opening when positive air pressure is applied to properly ventilate the facility. They have galvanised steel construction and come with pre-punched mounting holes for ease in installation. Choose from an extensive range of these ceiling truss shutters, available in 32, 35, 42 and 43 inch lengths.
Wall Exhaust Shutters
Dayton exhaust shutters are suitable for installation on vents for preventing air backflow from exhaust fans. These shutters feature gravity-operated blades for automatically closing & keeping the shutter in shutoff position when the fan is in switched off state. Selected models feature flush mount design for preventing dust & debris from entering the vent and galvanised steel construction for high abrasion resistance. Choose from a wide variety of these exhaust shutters, available in 42, 54, 57, 56.5 & 63 inch fixed widths on Raptor Supplies.
Dayton exhaust shutters are suitable for installation on vents for preventing air backflow from exhaust fans. These shutters feature gravity-operated blades for automatically closing & keeping the shutter in shutoff position when the fan is in switched off state. Selected models feature flush mount design for preventing dust & debris from entering the vent and galvanised steel construction for high abrasion resistance. Choose from a wide variety of these exhaust shutters, available in 42, 54, 57, 56.5 & 63 inch fixed widths on Raptor Supplies.
| Style | Model | Type | Blade Material | Frame Material | Frame Depth | Max. Velocity | Number Of Panels | Mounting Hole Size | Fits Fan Dia. | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | 2FTW1 | €381.05 | |||||||||
| B | 4FZK1 | €833.50 | |||||||||
| A | 2FTX3 | €438.45 | |||||||||
| B | 4FZJ9 | €687.64 | |||||||||
| C | 2FTX8 | €382.40 | |||||||||
| B | 4FZJ8 | €545.95 | |||||||||
| D | 4FZJ2 | €757.20 | |||||||||
| D | 4FZJ1 | €646.31 | |||||||||
| E | 3HHN9 | €331.12 | |||||||||
| E | 3HHP1 | €664.15 | |||||||||
| E | 3HHP2 | €695.94 | |||||||||
| D | 45C663 | €1,104.34 | |||||||||
| D | 45C667 | €543.89 | |||||||||
| D | 45C666 | €352.74 | |||||||||
| D | 45C668 | €617.41 | |||||||||
| D | 45C662 | €954.89 | |||||||||
| F | 3HHN6 | €118.34 | |||||||||
| E | 2FTX1 | €194.49 | |||||||||
| G | 2FTX7 | €251.06 | |||||||||
| E | 3HHN4 | €92.93 | |||||||||
| H | 4FZJ7 | €455.39 | |||||||||
| H | 4FZJ6 | €423.60 | |||||||||
| I | 4FZJ5 | €385.37 | |||||||||
| H | 4FZJ4 | €342.18 | |||||||||
| H | 4FZJ3 | €321.86 |
Wall Shutters
Gable Shutter Aluminium 19 Long 19 Wide
Popular Search Queries
Explore More
- KEYSHAFT
- SDC
- Retrofit Kits
- Electric Winches
- Brass Pipe Fittings
- Precision Nut Drivers
- Head Pressure Controls
- TEKTON Adjustable Wrenches
- DIXON Domestic Bronze Gate Valves
- WORLDWIDE ELECTRIC Tapered Bushing Kits
- EATON M22 Series Surface Mounting Enclosures
- SPEC Metric Compression Springs, Music Wire, 21.6 mm Outside Dia.
- LAKELAND Hooded Coveralls, Zipper, Blue
- VIBCO V Series Pneumatic Ball Vibrators
- JOHN GUEST Swivel Male Elbows, NPTF Thread, Polypropylene White













