FREE delivery on orders over €150
YELLOW JACKET 42006 Mechanical Manifold, Red/Blue, 60 Inch Charging Hose | AF8NVR 29AU09

YELLOW JACKET 42006 Mechanical Manifold, Red/Blue, 60 Inch Charging Hose

Item: AF8NVRModel: 42006Cross Ref: 29AU09
7 In Stock

Ships within 2 days via

€261.99
10.00% off
€235.80 /unit
Add To Cart
Request a Quote

Payment

Product Specifications:

Item Mechanical Manifold Gauge Set
A2l Compatibility Not A2L Compatible
Accuracy -1% to +1%
Adjustment Material Stainless Steel
Adjustment Method Lever
Body Material Brass
Calibration Certificate Type Not Certified
Display Illumination Non-Illuminated
Display Type Analog
Features 1% Accuracy Gauges
For Refrigerant Type R-134A, R-22, R-404A
For Use With R-22, R-134A, R-404A Refrigerants
Gauge Diameter 3 1/8"
Gauge Type High Side/Low Side
Gauges High Side Red 0 to 500 psig
Gauges High Side Red 0 psig to 500 psig
Gauges Low Side Blue 30" Hg to 120 psi
Gauges Low Side Blue 30 in. hg to 120 psi
High Side Display Pressure - Maximum 500 psi
High Side Display Pressure - Minimum 0 psi
Hose Color Blue, Red, Yellow
Hose Connection Thread Direction Right Hand
Hose Connection Type SAE
Hose Length 5 ft.
Includes Gauge Boots Boot Not Included
Includes Sightglass Sightglass Not Included
Includes Vacuum Port Vacuum Port Included
Low Side Display Pressure - Maximum 120 psi
Low Side Display Pressure - Minimum 30 in. hg
Manifold Port Connection Gender Male
Manifold Port Connection Size 1/4"
Manifold Port Connection Thread Direction Right-Hand
Manifold Port Connection Type SAE
Material Forged Brass
Number Of Hoses 3
Number Of Valves 2
Overall Depth 11 7/8"
Overall Height 3 1/2"
Overall Width 10 5/8"
Pressure Resolution 5 psi
Pressure Units Measured Psi
Product Type Manifold Gauge Set
Promotion Restriction Not Eligible For Promotion
Series 41 Series
Temperature Resolution 1°F
Temperature Units Measured °F
Vacuum Port Connection Gender Male
Vacuum Port Connection Size 1/4"
Vacuum Port Connection Thread Direction Right Hand
Vacuum Port Connection Type SAE
Vacuum Port Size 1/4"
Warranty 1 yr.

Shipping Info:

Ship weight (kg) 1.83
Ship height (cm)9.53
Ship length (cm)30.48
Ship width (cm)27.31
HS code9026806000

Product Details:

YELLOW JACKET 42006 mechanical manifold is ideal for precise monitoring & regulation of pressure in refrigeration applications. It is used in HVAC, refrigeration and air conditioning applications. This manifold allows technicians to measure, evacuate & charge refrigerants accurately.

Features:

  • This UL-listed manifold has full porting designed to maximise capacity and flow and features colour-coded scales for effortless identification.
  • It is made with forged brass to ensure robust construction for lasting performance.
  • This manifold incorporates sliding double O ring pistons, effectively minimising wear and has nylon seats to extend durability.

Frequently Asked Questions:

Q. How do I clean and maintain this YELLOW JACKET manifold?

A.

  • Perform regular visual inspections for any signs of dirt, debris or damage.
  • Wipe external surfaces with a clean, damp cloth to remove dirt and dust.
  • Check hoses and fittings for wear or damage. Replace any damaged components promptly.
  • If necessary, use a mild detergent solution to clean stubborn stains on external surfaces. Ensure thorough rinsing afterwards.
  • Avoid using harsh chemicals or solvents that may damage the manifold's components.
  • Store the manifold in a clean, dry place when not in use and protect it from extreme temperatures.
  • Adhere strictly to the cleaning and maintenance guidelines provided in the manufacturer's user manual.
  • Regularly inspect O-rings and seals for signs of wear or damage. Replace them if necessary to maintain a proper seal.

Q. What are the factors to consider while choosing a manifold?

A.

  • Pressure ratings
  • Construction materials
  • Features
  • Hose length
  • Refrigerant compatibility
  • Temperature range

Q. What safety precautions should I take when installing this mechanical manifold?

A.

  • Use appropriate personal protective equipment, including safety glasses and gloves.
  • Ensure that the equipment you are connecting the manifold to is turned off before installation.
  • Check that the manifold is compatible with the refrigerants and pressures associated with your HVAC/R system.
  • Inspect the manifold, hoses and fittings for any visible damage or defects before installation.
  • Make sure all connections are secure and properly tightened to prevent leaks.
  • Ensure that hoses and components are clean and dedicated to specific refrigerants.
  • Use appropriate tools for installation and do not force connections.
  • If the system is under pressure, release it safely before connecting the manifold.
  • Follow the correct sequence of steps outlined in the installation manual to ensure proper installation.
  • Inspect seals and O-rings for wear & damage and replace them if needed.
  • Bleed air from the manifold and hoses before connecting to the system to prevent air pockets.
  • Avoid over-tightening fittings, which can damage threads and seals.
  • After installation, perform a leak check to ensure there are no refrigerant leaks.

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

YELLOW JACKET 42006 Mechanical Manifold, Red/Blue, 60 Inch Charging Hose
€261.99 /unit