Product Specifications:

Item Gas Regulator
Application Purging
Body Material Brass
Cga Number RP_CGA 580
Coefficient Of Volume 0.109
Compatible Gas Type Nitrogen
Control Type T-Handle
Delivery 9000 SCFH
Delivery Pressure Range 10 psi to 400 psi
Diaphragm Material Neoprene
Duty Rating Light Duty
Features Single Stage Design, Stem Type Seat Mechanism
For Gas Type Nitrogen
Gas Service Argon, Helium, Nitrogen
Gauge Diameter 2"
Gauge Size 2"
Gauges Delivery Pressure 200 psi
Height 5.1"
Includes Not Applicable
Inlet Connection CGA 580
Inlet Connection Gender Male
Inlet Connection Size 0.965"-14
Inlet Connection Type NGO
Inlet Pressure (maximum) 3000 psig
Inlet Thread Direction Right Hand
Max. Inlet Pressure 3000 psi
Maximum Gauge Outlet Pressure 4000 psig
Mounting Type Cylinder
Number Of Stages 1
Outlet Connection 1/4"
Outlet Connection Gender Female
Outlet Connection Size 1/4"-37
Outlet Connection Type 37° Flared Tube
Outlet Pressure (maximum) 400 psi
Outlet Pressure (minimum) 10 psi
Overall Depth 4.25"
Overall Height 5.1"
Overall Length 6 1/4"
Overall Width 6.38"
Regulator Application Purging
Regulator Capacity Light Duty
Regulator Series Tpr 250 Series
Regulator Supply Type Cylinder
Supply Pressure Gauge 4000 psi
Width 6.38"

Shipping Info:

Ship weight (kg) 1.45
Ship height (cm)22.35
Ship length (cm)12.19
Ship width (cm)20.32
HS code8481100090
Country of OriginMX

Product Details:

The Victor 250 Series regulator, 0781-9134 is a light-duty, medium-capacity purging regulator. It features single-stage design, suitable for use in the light to medium-duty air conditioning operations. Victor 250 Series regulator has a forged brass body for structural rigidity and a Derlin housing cap with 2 inch gauges to provide smooth adjustment. It offers stem type seat mechanism, designed for accurate gas flow and has a neoprene diaphragm to ensure proper usage in any condition. This Victor 250 Series regulator is suitable to regulate and control the flow of high-pressure gases, including argon, hydrogen, nitrogen, oxygen in a cylinder. Victor 250 Series regulator unit requires a CGA-580 inlet connection for quick and effective installation without the need for a wrench or thread sealant.

Uses:

Victor 250 Series regulator, 0781-9134, offers a wide combination of features, making it useful for welding and cutting torches in light to medium-duty air conditioning operations.

Features:

  • Victor 250 Series regulator, 0781-9134 is designed for light to medium-duty operations in air conditioning, purging and welding applications.
  • This purging regulator has a forged brass body, ensuring structural rigidity, a Derlin housing cap with 2 inch gauges to provide smooth adjustment.
  • The stem type seat mechanism of the unit is suitable for accurate gas flow.
  • Further, the neoprene constructed diaphragm is built for proper usage in any condition.
  • It delivers pressures ranging from 10 to 250 psi and a maximum inlet pressure of 3000 psi.

Standards and Approvals:

  • Victor 250 Series regulator, 0781-9134 is listed to UL252 by ETL to deliver high quality services and user safety.

Installation:

  • Victor 250 Series regulator, 0781-9134 uses CGA-580 inlet connection for quick and effective installation without the need for a wrench or thread sealant.
  • Close the outlet valve and open the tank valve. This will pressurise the regulator.
  • Adjust the regulation pressure to approximately 20% of range.
  • Close the tank valve and crack the valve on the regulator outlet.
  • Allow the gas to discharge until the regulator pressure gages approach zero.
  • Close the outlet valve prior to releasing the last bit of gas pressure.
  • After the purge cycles, open the tank valve, and set the regulator to the proper operating pressure.
  • Crack the outlet valve slightly and reattach the gas line to the analyzer.
  • Open the outlet valve fully.

Frequently Asked Questions:

Q. What is the difference between a single-stage and two-stage regulator?

A. Single-stage gas pressure regulators minimise cylinder pressure to outlet or delivery pressure in one step, whereas two-stage gas pressure regulators eliminate cylinder pressure in two steps, delivering a constant outlet pressure without periodic readjustment.

Q. Do gas regulators need to be vented?

A. The natural gas regulator is a sensitive component of the metre set, requiring it to be vented and complied with federal and local venting needs. The vent functions as a safety measure, permitting the diaphragm within the regulator to breathe.

Q. How does a regulator fail?

A. A regular can fail when the excessive flexing of the metal diaphragm causes a radial crack and permits gas to escape to the atmosphere through the vent hole configured in the bonnet. Another most common type of regulator failure is the internal leak, also known as crawl or creep.

Q. Why must the pressure be released from a regulator when work is finished?

A. The pressure from a regulator is released, after finishing the work, to protect damage to the diaphragm, gauges & adjusting springs (if under a load).

Product Variants

ProductModelOverall LengthGauges Delivery PressureSupply Pressure GaugeRegulator CapacityDeliveryOutlet Connection SizeApplicationMaximum Gauge Outlet PressurePrice
VICTOR 0781-9135 Regulator Purging | AE4GZQ 5KJ83 / TPR250-500-580CS 0781-91356 1/2"400 psi3000 psiMedium Duty5800 SCFH1/4"General Purpose3000 psig€470.38

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

VICTOR 0781-9134 Regulator Cylinder Argon Helium Nitrogen Cga-580
€444.30 /unit