Product Specifications:
| Item | Bolt On Circuit Breaker |
| Ac Voltage Rating | 120/240V AC |
| Amps | 10A |
| Circuit Breaker Actuator | Toggle |
| Circuit Breaker Mounting Style | Surface/Din Rail |
| Circuit Breaker Type | Standard |
| Compatible Panelboard/load Center Series | Series QO |
| Dc Voltage | 48V DC |
| Dc Voltage Rating | 48V |
| Depth | 2.95" |
| For Use With | Air Conditioning And Refrigeration Equipment, Heating |
| Frame Size | 100A, QOU |
| Frequency | 50/60 Hz |
| Length | 4.05" |
| Max. Air Rating | 10kA |
| Max. Air Rating | 10 kA At 120/240V AC |
| Max. Wire Size | 2 AWG |
| Min. Wire Size | 14 AWG |
| Mounting Type | Bolt On |
| Number Of Poles | 1 |
| Phase | 1 |
| Product Datasheet | square-d-qou110.pdf |
| Temp. Rating | 140 Deg. F |
| Temp. Rating | 140°F |
| Terminal Connection | Slotted Box Lug (Reversible Line And Load) |
| Type | Standard |
| Use With | QO Series |
| Width | 3/4" |
Shipping Info:
| Ship weight (kg) | 0.18 |
| Ship height (cm) | 2.54 |
| Ship length (cm) | 11.43 |
| Ship width (cm) | 7.87 |
| HS code | 8536200040 |
| Country of Origin | MX |
Product Details:
Square D QOU110 miniature circuit breaker is used in commercial electrical systems to provide overcurrent protection, preventing damage and fires. It is ideal for protecting branch circuits, lighting and outlets, ensuring safe and reliable electricity distribution in buildings and offices.
Features:
- This single pole circuit breaker features a toggle actuator for easy manual operation and a DC voltage rating of 48VDC.
- It can be mounted either on the surface or on a DIN rail, providing flexibility in installation.
- This Square D QOU110 circuit breaker has terminal connections with slotted box lugs, which are reversible for both line and load connections.
- It has a frame size of 100A / QOU and can accommodate wire sizes ranging from 14 to 2 AWG.
Frequently Asked Questions:
Q. How do I install Square D QOU110 mini breaker?
A.
- Turn off power to the panelboard by switching off the main breaker or disconnecting the power source.
- Choose a compatible slot in the panelboard for the QOU110 circuit breaker.
- Connect the load and line wires to the appropriate terminals on this QOU110 circuit breaker.
- Align and securely snap the breaker into the chosen slot, ensuring proper engagement.
- Close the panelboard cover, turn on the power, and test the circuit to ensure proper functioning.
Q. How to reset this miniature breaker after it trips?
A. After identifying and addressing the cause of the trip, you can reset the breaker by toggling its actuator to the OFF position and then back to ON.
Q. What wire size can Square D QOU110 mini breakeraccomodates?
A. It can accommodate 14 to 2 AWG aluminium / copper wires.
Q. What maintenance does this miniature circuit breaker box require?
A. Regularly inspect the breaker for signs of wear, overheating or corrosion. Verify that connections are tight and there's no physical damage.
Q. How do I clean and maintain Square D QOU110 miniature circuit breaker?
A.
- De-energise the circuit.
- Carefully remove the breaker.
- Inspect for damage or wear.
- Use a clean, dry cloth for cleaning.
- Replace if damaged.
- Reinstall securely.
- Restore power and verify functionality.
Q. When should I replace this miniature circuit breaker?
A.
- If it trips frequently.
- When damaged or worn.
- After a significant electrical fault.
- When unable to reset.
- If it no longer provides overcurrent protection.
Q. What factors should I consider while choosing a circuit breaker?
A.
- Current rating
- Voltage rating
- Trip type
- Number of poles
- Short circuit rating
- Applications
- Electrical standards compliance
Documentation:
Product Variants
| Model | Amps | Circuit Breaker Type | Max. Air Rating | Dc Voltage Rating | Terminal Connection | Min. Wire Size | Dc Voltage | Number Of Poles | Price | |
|---|---|---|---|---|---|---|---|---|---|---|
| QOU115VH | 15A | Standard | 22 kA At 120/240V AC | 48V | Slotted Box Lug (Reversible Line And Load) | 14 AWG | 48V DC | 1 | €186.16 | |
| QOU120VH | 20A | Standard | 22 kA At 120/240V AC | 48V | Slotted Box Lug (Reversible Line And Load) | 14 AWG | 48V DC | 1 | €180.32 | |
| QOU1201021 | 20A | Standard | 10 kA At 120/240V AC | 48V | Slotted Box Lug (Line And Load) | 14 AWG | 48V DC | 1 | €412.39 | |
| QOU125VH | 25A | Standard | 22 kA At 120/240V AC | 48V | Slotted Box Lug (Reversible Line And Load) | 14 AWG | 48V DC | 1 | €162.92 | |
| QOU130VH | 30A | Standard | 22 kA At 120/240V AC | 48V | Slotted Box Lug (Reversible Line And Load) | 14 AWG | 48V DC | 1 | €179.15 | |
| QOU150VH | 50A | Standard | 22 kA At 120/240V AC | 48V | Slotted Box Lug (Reversible Line And Load) | 14 AWG | 48V DC | 1 | €164.31 | |
| QOU180 | 80A | Standard | 10 kA At 120/240V AC | 60V DC | Slotted Box Lug (Non-Reversible Line And Load) | 12 AWG | 60V DC | 1 | €340.90 |
Explore Products
- TB WOODS 14012D Classical V-Belt Sheave, Cast Iron, D Type Belt, 14 inch Datum Dia.
- BISHOP-WISECARVER UTCTPA2-2190-SS Track Plate Assembly, Stainless Steel, 2190 mm Length
- BALDOR / DODGE 23QZ12L56WP TIGEAR-2 E-Z KLEEN Reducer-White
- EATON 1420B-6501 Photoelectric Sensor, Right Angle, Beam Status, Screw Terminals, 100-125V
- APOLLO VALVES 8305864 Service Kit
- DORIAN DST-42FBC-L68.81-STFCL11
- USA SEALING ZUSA-VLV-24 Ball Valve, 3/8 Inch Pipe, 1/4 Inch Tube, 1000 PSI CWP, -20-350 Deg F, Female NPT
- SHEPHERD CASTER PEC40507BK-TPU03(KK)B Swivel Stem Caster With Brake 4 Inch 125 Lb
Explore More
- CHASE DOORS
- GARDNER BENDER
- KEYSHAFT
- START INTERNATIONAL
- DLAB
- Sump Pump Accessories
- Fan and Limit Controls
- Tip Out Bins
- Personal Eye Wash Stations
- Load Binders
- OIL SAFE Color-Coded Steel Tube Grease Guns, Pistol Grip
- CONDOR High Visibility Orange Palm Gloves
- CAMLOCK FITTINGS Type C Female Cam And Groove Coupler, Hose Shank
- ANVIL C160 Series Cable Toggles
- PASS AND SEYMOUR Stainless Steel Safety Switches
- MARTIN SPROCKET Reborable Type Miter Gears, Unhardened Teeth, 8 Pitch
- SECURALL PRODUCTS LP And Oxygen Gas Storage Aluminum Cabinets
- SMC VALVES Cls1 Series One Way Lock-Up Cylinder
- WATTS P777 Series Y Wye Strainers
Contact us