Product Specifications:
| Item | Circuit Breaker |
| Ambient Air Temp. For Operation | -13°F to +158°F |
| Ambient Air Temp. For Storage | -58°F to +185°F |
| Amps | 125A |
| Awg Gauge | 14 AWG to 3/0 AWG |
| Breaking Capacity | 65 kA 240V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 18 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 20 kA 500V DC UL 489 |
| Breaking Capacity Code | G |
| Circuit Breaker Application | HACR Rated |
| Color | Black |
| Communication Interface | Modbus, Ethernet |
| Component Type | Circuit Breaker |
| Continuous Amps Rating | 80% |
| Control Type | Toggle |
| Depth | 3.4" |
| Device Application | Distribution |
| Electrical Connection | Terminal Nut, Line, Lugs, Load |
| Frame Type | HGP |
| Height | 6 2/5" |
| Ip Degree Of Protection | IP40 |
| Line Rated Amps | 125A |
| Local Signalling | Switched Off 1 Trip Indicator Green |
| Magnetic Hold Amps | 900A |
| Magnetic Tripping Amps | 1700A |
| Mounting Mode | Unit Mount Lug |
| Mounting Support | Lug |
| Network Frequency | 50/60 Hz |
| No. Of Poles | 3 |
| Number Of Poles | 3 |
| Number Of Slots | 5 |
| Operating Altitude | 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating |
| Pollution Degree | 3 IEC 60947-1 |
| Power Wire Stripping Length | 0.6" |
| Quality Labels | ce.png |
| Quantity Per Set | 1 |
| Rated Impulse Withstand Voltage | 8 kV |
| Rated Insulation Voltage | 750V |
| Rated Operational Voltage | 690V |
| Rated Service Breaking Capacity | 65 kA @ 220/240V AC @ 50/60 Hz, 35 kA @ 380/440/415V AC @ 50/60 Hz, 18 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC |
| Returnability | Yes |
| Suitability For Isolation | Yes, IEC 60947-2 |
| Tightening Torque | 44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG |
| Trip Unit Technology | Thermal-Magnetic |
| Utilisation Category | Category A |
| Voltage | 600V |
| Voltage Type | AC |
| Width | 4.09" |
Shipping Info:
| Ship weight (kg) | 1.8 |
| Ship height (cm) | 16.3 |
| Ship length (cm) | 8.6 |
| Ship width (cm) | 10.4 |
| Country of Origin | US |
Product Details:
- Square D HGP36125 circuit breaker designed to protect electrical systems from short-circuiting or overloading
- Features a non-interchangeable, thermal-magnetic trip for both long-time and instantaneous current limiting protection
- Unit mount construction with built-in load side lug terminals ensure easy installation
- Accommodates copper and aluminium wires (14 - 3 AWG)
- UL, CSA, IEC, CE and CCC certified
Explore Products
- BOSTON GEAR GB35 Change Gear, 16 Diametral Pitch, 14 1/2 Deg. Pressure Angle, 35 Teeth, Steel
- REELCRAFT A5835OMP Hose Reel, Inner Diameter 1/2 Inch, 3000 Psi, Hose Length 35 Feet
- RPM ENGINEERING SBRMS35489-68 Rubber Gro mmet, 1 Inch Outside Dia, 5/16 Inch Inside Dia, 68, Black
- DORIAN E10M-M-SDXCL-07
- PIP 64-V2000/S Hand Protection Disposable Gloves, S, White, Box
- APPLETON ELECTRIC MLBG15LMTS Ballast Body, 277V
- SCHLAGE F170 ACC 609 LH Door Lever Lockset, Grade 2, Accent, Antique Brass, Not Keyed
- PIP 1816-5 Welding Protection Gloves, L, Pair
Explore More
- ACTION PUMP
- KEYSHAFT
- MEC-O-MATIC
- DEAD ON TOOLS
- Terminal Block Accessories
- Conduit Wire Cable Racks/Stands/Carts
- Turntables
- Hacksaw and Coping Saw Blades
- Coil Bolts
- ADB HOIST RINGS MFG. Shackle Hoist Rings
- CONDOR Hooded Coveralls
- MECHANIX TAA Fastfit Covert Tactical Gloves
- LOUISVILLE FM1400HD Series Fiberglass Twin Front Ladders
- ASSOCIATED SPRING RAYMOND Powerline X4200 Gas Springs
- MAIN FILTER INC. Hydraulic Filters, Wire Mesh, 40 Micron
- PLAST-O-MATIC PRAM Series Air Loaded Pressure Regulators
- CEMENTEX USA Arc Flash Hoods, 12 Cal.
- BROWNING C Series Gripbelt Sheaves With Split Taper Bushings, 5 Grooves
- GLOBE SCIENTIFIC NexiusZoom EVO Trinocular Stereo Zoom Microscopes
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
SQUARE D HGP36125 PowerPact H Circuit Breaker, 125A, Thermal Magnetic Trip