Product Specifications:

Item Circuit Breaker
Accessory/separate Part Type Shunt Trip 110-130V AC Compartment
Ambient Air Temp. For Operation -13°F to +158°F
Ambient Air Temp. For Storage -58°F to +185°F
Amps 60A
Awg Gauge 14 AWG to 3/0 AWG
Breaking Capacity 65 kA 240V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 18 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 20 kA 500V DC UL 489
Breaking Capacity Code G
Circuit Breaker Application HACR Rated
Color Black
Communication Interface Modbus, Ethernet
Component Type Circuit Breaker
Continuous Amps Rating 80%
Control Type Toggle
Depth 3.4"
Device Application Distribution
Electrical Connection I-Line Connection, Line, Lugs, Load
Frame Type HGA
Height 6 2/5"
Ip Degree Of Protection IP40
Line Rated Amps 60A
Local Signalling Switched Off 1 Trip Indicator Green
Magnetic Hold Amps 800A
Magnetic Tripping Amps 1450A
Mounting Height 4.5"
Mounting Mode I Line Bracket
Mounting Support Bracket
Network Frequency 50/60 Hz
No. Of Poles 3
Number Of Poles 3
Number Of Slots 5
Operating Altitude 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase Connection ABC
Pollution Degree 3 IEC 60947-1
Power Wire Stripping Length 0.6"
Quality Labels ce.png
Quantity Per Set 1
Rated Impulse Withstand Voltage 8 kV
Rated Insulation Voltage 750V
Rated Operational Voltage 690V
Rated Service Breaking Capacity 65 kA @ 220/240V AC @ 50/60 Hz, 35 kA @ 380/440/415V AC @ 50/60 Hz, 18 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability No
Suitability For Isolation Yes, IEC 60947-2
Tightening Torque 44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
Trip Unit Technology Thermal-Magnetic
Utilisation Category Category A
Voltage 600V
Voltage Type AC
Width 4.09"

Shipping Info:

Ship weight (kg) 2.25
Ship height (cm)16.31
Ship length (cm)8.61
Ship width (cm)10.39
Country of OriginUS

Product Details:

    • Square D HGA36060SA circuit breaker limits let-through currents, offering maximum protection for downstream components
    • Thermal magnetic trip unit allows both instantaneous and time-delayed functions for maximum overcurrent protection
    • Unique I-Line design with lug load terminals provides easy installation and hassle-free wiring configuration
    • Includes low power shunt trip rated at 120VAC for remote opening of contacts to protect the solenoid
    • UL-listed, CSA-certified and CE-marked

Product Variants

ProductModelNumber Of PolesPhase ConnectionAmpsPhaseFrame SizeMounting HeightHigh Amp Trip SettingLow Amp Trip SettingPrice
SQUARE D HGA261251 Circuit Breaker 125a 2p 600vac Lug | AF9GRC 2GNJ1 HGA2612512AB125A1150A/HG3"1700A900A€1,818.08
SQUARE D HGA261252 Circuit Breaker 125a 2p 600vac Lug | AF9GRF 2GNJ4 HGA2612522AC125A1150A/HG3"1700A900A€1,818.08
SQUARE D HGA260151 Circuit Breaker 15a 2p 600vac Lug | AF9GZF 2GMZ9 HGA2601512AB15A1150A/HG3"750A350A€2,768.63
SQUARE D HGA260152 Circuit Breaker 15a 2p 600vac Lug | AF9GZG 2GNA1 HGA2601522AC15A1150A/HG3"750A350A€2,369.69
SQUARE D HGA260154 Circuit Breaker 15a 2p 600vac Lug | AF9GZH 2GNA2 HGA2601542BC15A1150A/HG3"750A350A€1,212.01
SQUARE D HGA260201 Circuit Breaker 20a 2p 600vac Lug | AF9GZJ 2GNA3 HGA2602012AB20A1150A/HG3"750A350A€1,212.01
SQUARE D HGA260202 Circuit Breaker 20a 2p 600vac Lug | AF9GZK 2GNA4 HGA2602022AC20A1150A/HG3"750A350A€1,212.01

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

SQUARE D HGA36060SA Molded Case Circuit Breaker, 60A, ABC Phase, Shunt Trip
€1,616.03 /unit