FREE delivery on orders over €150
Product Specifications:
| Item | Circuit Breaker |
| Ac Voltage | 525V AC |
| Ac Voltage Rating | 525V AC |
| Ambient Air Temp. For Operation | -13°F to +158°F |
| Ambient Air Temp. For Storage | -58°F to +185°F |
| Amps | 50A |
| Breaking Capacity Code | D |
| Circuit Breaker Mounting Style | Unit Mount |
| Circuit Breaker Type | Standard |
| Comm Code Enhanced | 32322 |
| Continuous Amps | 80% |
| Curve Type | B |
| Depth | 3.1" |
| Device Short Name | BD 050 |
| Discount Schedule | 0DE2 |
| Electrical Durability | 10000 Cycles IEC 947-1 Annex K Ed 5.2 440V |
| For Use With | Electrical Distribution Equipment, Industrial Control Panels |
| Frame Size | 125a/Bd |
| Height | 5 2/5" |
| Ics Rated Service Breaking Capacity | 25 kA 220-240V AC 50/60 Hz, 14 kA 500-525V AC 50/60 Hz, 18 kA 380-415V AC 50/60 Hz, 18 kA 440V AC 50/60 Hz |
| Ip Degree Of Protection | Front Cover IP40 IEC 60529 |
| Max. Air Rating | 25 kA at 277/408V AC |
| Max. Wire Size | 2 AWG, 3 AWG |
| Mechanical Durability | 15000 Cycles IEC 947-1 Annex K ed 5.2 |
| Min. Wire Size | 14 AWG, 6 AWG |
| Mounting | Clip-On |
| Mounting Type | Unit |
| No. Of 9 Mm Pitches | 6 |
| No. Of Poles | 2 , 2P |
| Operating Altitude | 6561.68 ft. (2000m) Without Derating 5000m With Derating |
| Phase | 1 |
| Phase Connection | Not Applicable |
| Pollution Degree | 3 IEC 60947-1 |
| Power Wire Stripping Length | 4/5" |
| Product Or Component Type | Circuit Breaker |
| Quality Labels | CE |
| Range | Powerpact |
| Reset Actuator Type | Toggle Switch |
| Series | BDL Series |
| Suitability For Isolation | Yes |
| Terminal Connection | Everlink Lug Both Ends |
| Terminal Connection Type | Lug |
| Trip Type | Thermal Magnetic |
| Tripping Mechanism | Thermal-Magnetic |
| Ui Rated Insulation Voltage | 800V |
| Uimp Rated Impulse Withstand Voltage | 8 kV |
| Voltage | 525V |
| Voltage Dc | Not Rated |
| Width | 2.1" |
| Wire Size | 14 AWG to 3/0 AWG |
Shipping Info:
| Ship weight (kg) | 0.95 |
| Ship height (cm) | 6.86 |
| Ship width (cm) | 16.51 |
| Country of Origin | US |
Product Variants
| Product | Model | No. Of Poles | Amps | Voltage | Phase | Ac Voltage Rating | No. Of 9 Mm Pitches | Circuit Breaker Type | Mechanical Durability | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BDL36060LU | 3 , 3P | 60A | - | 3 | 525V AC | 9 | Standard | 15000 Cycles IEC 947-1 Annex K ed 5.2 | €1,717.07 | |
![]() |
BDL36070LU | 3 , 3P | 70A | - | 3 | 525V AC | 9 | Standard | 15000 Cycles IEC 947-1 Annex K ed 5.2 | €2,075.91 | |
![]() |
BDL36080LU | 3 , 3P | 80A | 525V | 3 | 525V AC | 9 | Standard | 15000 Cycles IEC 947-1 Annex K ed 5.2 | €1,885.32 | |
![]() |
BDL36090LU | 3 , 3P | 90A | - | 3 | 525V AC | 9 | Standard | 15000 Cycles IEC 947-1 Annex K ed 5.2 | €2,935.82 | |
![]() |
BDL36100LU | 3 , 3P | 100A | - | 3 | 525V AC | 9 | Standard | 15000 Cycles IEC 947-1 Annex K ed 5.2 | €2,065.38 | |
![]() |
BDL36110 | 3 , 3P | 110A | 600/347V AC | 3 | 525V AC | 9 | Standard | 20000 Cycles IEC 947-1 Annex K ed 5.2 | €1,574.00 | |
![]() |
BDL16025 | 1 , 1P | 25A | - | 1 | 240V AC | 3 | Standard | 15000 Cycles IEC 947-1 Annex F ed 5.2 | €513.57 |
Explore More
- KEYSHAFT
- Low Voltage Thermostats
- Transfer Tape
- Finger Cots
- Float Operated Drain Valves
- Gauge Repair Tools
- AUTOQUIP Coil Transfer Cars
- MOON AMERICAN Male Dry Hydrants, With 45 Deg. Elbow
- JOHN GUEST Fixed Elbows, NPTF Thread, Polypropylene White
- VIBCO BV Series Pneumatic Ball Vibrators
- SHUR-LINE Premium Mini Rollers
- MAIN FILTER INC. Interchange Hydraulic Filters, Wire Mesh, 500 Micron
- HOFFMAN Lay In Wireway 90 Degree Elbow Transposition Sections
- DUPONT Collared Disposable Coveralls
- WATTS DETA Series Expansion Tanks
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
SQUARE D BDL26050LU Molded Case Circuit Breaker, 50 A, 2 Pole, 525V AC