Product Specifications:
| Item | Controller |
| Amps | 1A |
| Application | Heat Or Cool |
| Backlit Screen | Yes |
| Backlit Type | Motion Activated |
| Compatible System Type | Rtu |
| Connection | Screw Terminals |
| Connection Type | Screw Terminals |
| Contact Rating | 24V AC |
| Control Output | Single Stage RTU, Heat Pump With Economizer, Two Stage RTU, Heat Pump With Economizer |
| Control Type | Push Button |
| Dehumidification Control | Yes |
| Dimensions | 1" x 1.047" |
| Display Type | Digital |
| Dual Transformer Compatible | Yes |
| Electrical Connection Type | Hardwired |
| Enclosure Color | White |
| For Use With | Rooftop Units, Split Systems |
| Frequency | 50/60 Hz |
| Housing Color | White |
| Housing Material | Plastic |
| Housing Type | Flame Retardent Housing |
| Humidification Control | Yes |
| Includes | Backplate |
| Inputs | Thermistors Type II Or III |
| Key Features | Economizer, Fan Control, Modulating, On/Off Valves |
| Lead Wire Gauge | 14 ga., 22 ga. |
| Maximum Operating Humidity | 100% |
| Maximum Operating Temperature | 140°F |
| Minimum Operating Humidity | 0% |
| Minimum Operating Temperature | 32°F |
| Mounting Direction | Horizontal |
| Mounting Location | Wall |
| Network Protocol Compatibility | Bacnet MS/TP |
| Number Of Cooling Stages (conventional System) | 1 |
| Number Of Cooling Stages (heat Pump System) | 2 |
| Number Of Heating Stages (conventional System) | 2 |
| Number Of Heating Stages (heat Pump System) | 2 |
| Number Of Pipes | 2, 4 |
| Number Of Poles | 1 |
| Number Of Relay Control Output | 6 |
| Number Of Relay Inputs | 0 |
| Number Of Relay Inputs/outputs | 0 |
| Number Of Relay Outputs | 6 |
| Occupancy Sensor | Includes Onboard Occupancy Sensor |
| Outputs | Analog/Binary |
| Overall Depth | 1 1/8" |
| Overall Height | 5 1/8" |
| Overall Width | 3 1/2" |
| Remote Control Functions | Temperature Control |
| Screen Height | 1 1/16" |
| Screen Width | 1" |
| Sensor Length | 33 ft. |
| Sensor Location | Remote |
| Sensor Type | Thermistor |
| Switch Type | SPST |
| Temp. Sensitivity | -0.36°F to +0.36°F |
| Temperature Adjustment | Floating, On/Off |
| Temperature Scale | Fahrenheit, Celsius |
| Terminal Designations | -A, +B, AO6, AO7, AO8, BO5, COM, DAT, FAN-H, FAN-L, FAN-M, GND, RBO4, RS, WST |
| Thermostat Type | Low Voltage |
| Type | Bacnet |
| Voltage | 24V AC |
| Wireless | Hardwired |
Shipping Info:
| Ship weight (kg) | 0.21 |
| Ship height (cm) | 5.08 |
| Ship length (cm) | 15.24 |
| Ship width (cm) | 13.65 |
| HS code | 9017900136 |
Product Variants
| Model | Electrical Connection Type | Connection | Dimensions | Mounting Direction | Dehumidification Control | Humidification Control | Application | Compatible System Type | Price | |
|---|---|---|---|---|---|---|---|---|---|---|
| BAC-4001CW0001 | Plug In | Screw Terminals | 1" x 1.047" | Vertical | No | No | Heat And Cool | Fan Coil Units | €660.50 | |
| BAC-4001CW0002 | Plug In | Screw Terminals | 1" x 1.047" | Vertical | No | No | Heat And Cool | Rtu | €682.41 | |
| BAC-4001CW0003 | Plug In | Screw Terminals | 1" x 1.047" | Vertical | No | No | Heat And Cool | Heat Pumps With Aux | €682.41 | |
| BAC-4002CW0001 | Plug In | Screw Terminals | 1" x 1.047" | Vertical | No | No | Heat And Cool | Fan Coil Units | €682.41 | |
| BAC-4003CW0002 | Plug In | Screw Terminal | 1" x 1 3/64" | Vertical | No | No | Heat And Cool | Rtu | €700.92 | |
| BAC-4003CW0003 | - | Screw Terminal | 1" x 1 3/64" | - | - | - | - | - | €700.92 | |
| BAC-4007CW0001 | Plug In | Screw Terminals | 1" x 1.047" | Vertical | No | No | Heat And Cool | Fan Coil Units | €682.41 |
Explore Products
- SLOAN 3345095 EL-1034-A Repair Kit
- BUSSMANN TCF90RN Midget Fuse, Slow Blow, 90A, 600VAC
- ENCORE SS10-5808 Showerhead Adapter With Hoop, 1/2 Inch Connection Size, Male Npsm Connection
- WRIGHT TOOL 3864 Standard Universal Power Socket, 3/8 Inch Drive, 6 Point, 3/4 Inch Size
- EATON S811+U50N3S Soft Start, 600 VAC, 500 A Output Current, With Bypass, 150HP, 3 Phase, 208 VAC
- T&S 108V-RK Valve Repair Kit
- MERIT BRASS KP611H-16 Half Coupling, 1 in Nominal, FNPT End Style, 150 lb, 316/316L Stainless Steel, Import
- CASH VALVE FRM-ACZRZSZF03-E6 Cryogenic Valve, 1/4 Inch Size, 100-250 PSI, Stainless Steel, Fillister Screw
Explore More
- CRUSHPROOF
- KEYSHAFT
- MASTER CASTER
- PRESTO LIFTS
- QUANTUM STORAGE SYSTEMS
- Sanitary Butterfly Valves
- Marking Tape Applicators
- Gladhands
- Universal AC/DC Motors
- Pipe Picks
- LAKELAND Hooded Coveralls, Zipper, Blue
- VIEGA PROPRESS Caps, SS, Press Connection, FKM Seal
- FACOM 115A Monkey Wrenches
- FACOM 46 VSE Series Insulated Open End Wrenches, 1000 Volt
- DAYTON 240VAC, Relay
- RONSTAN Screw Pin D Shackle
- BALDOR / DODGE QD, SDS Size Bushings
- SIEMENS Multifunction Time Delay Relays
- MERIT BRASS 4216 304 Stainless Steel Seamless Nipples, Schedule 40
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
KMC CONTROLS BAC-4223CW0002 Controller Bacnet Rooftop Units Split