Product Specifications:

Item Gas Regulator
Application Industrial Purpose
Body Diameter 2.75"
Body Finish Chrome Plated
Body Material Brass
Cga Number RP_CGA 540
Coefficient Of Volume 0.17
Control Type T-Handle
Cylinder Gas Oxygen
Delivery Pressure Range 0 psi to 200 psi
Diaphragm Material Neoprene
Features Designed To Make It A Rugged, Long Lasting Performer, Including An Exclusive Tamper Proof, Self Reseating Internal Hp Safety Valve, Pipelines Classic Kits
Flow Coefficient 0.17
For Gas Type Oxygen
Gas Service Oxygen
Gauge Diameter 2 1/2"
Gauge Size 2.5
Gauges Delivery Pressure 400 psig
Inlet Connection CGA 540
Inlet Connection Gender Male
Inlet Connection Size 0.825"-14
Inlet Connection Type NGO
Inlet Gauge 4000 psi
Inlet Pressure (maximum) 3000 psig
Inlet Thread Direction Right Hand
Max. Inlet Pressure 3000 psi
Maximum Gauge Outlet Pressure 4000 psig
Mounting Type Cylinder
Number Of Stages Single
Outlet Connection 9/16"-18
Outlet Connection Gender Male
Outlet Connection Size 9/16"-18
Outlet Connection Type Male RH
Outlet Pressure (maximum) 200 psig
Outlet Pressure (minimum) 0 psig
Outlet Thread Direction Right Hand
Overall Depth 4.5"
Overall Height 6 1/2"
Overall Length 6 3/4"
Overall Width 6 3/4"
Regulator Capacity Heavy Duty
Regulator Series 425 Series
Seal Material PTFE
Standards Cga E-4, Ul Listed
Supply Pressure Gauge 4000 psi
Type Single Stage Cylinder

Shipping Info:

Ship weight (kg) 1.98
Ship height (cm)19.81
Ship length (cm)19.56
Ship width (cm)18.03
HS code8481809015
Country of OriginUS

Product Details:

Harris 425-200-540 oxygen single-stage regulator offers accurate pressure regulation for welding, cutting and brazing applications. The regulator ensures that the pressure of the gas is kept at a safe and consistent level for the specific application, allowing for precise control and optimal performance.

Features:

  • It has a one-piece encapsulated seat design with an internal filter and a PTFE Teflon seat to resist corrosion, tearing and wearing.
  • This regulator features a brass bonnet & body for improved flow control.
  • It has a bronze adjusting screw for easy regulator adjustment.

Standards and Approvals:

  • CGA-E-4

Frequently Asked Questions:

Q. How much inlet and outlet does this regulator have?

A. This regulator has a 540 CGA-inlet and a minimum 9/16 inch right-hand outlet along with a self-reseating HP safety valve (internal) for enhanced safety.

Q. How to clean Harris 425-200-540 oxygen regulator?

A.

  • Turn off the oxygen supply and disconnect the regulator from the cylinder valve.
  • Disassemble the regulator and clean the body and internal components with a clean, lint-free cloth, soft-bristled brush and compressed air.
  • Wash the components with mild soap and water, rinse thoroughly and dry completely.
  • Apply a small amount of lubricant to the O-ring or other sealing components.
  • Reassemble the regulator and ensure all components are securely fastened.
  • Test the regulator to ensure it's functioning properly.

Q. How to install this oxygen regulator?

A.

  • Ensure the cylinder valve is closed.
  • Remove the protective cap from the cylinder valve and check the valve outlet to ensure it is free from damage or debris.
  • Match the regulator fitting to the cylinder valve. Harris 425-200-540 regulator has a CGA 540 connection, so make sure the cylinder valve has a matching CGA 540 connection.
  • Attach the regulator to the cylinder valve by positioning the regulator over the cylinder valve and hand-tightening the regulator yoke screw or T-handle onto the cylinder valve. Use a wrench to tighten the regulator an additional 1/8 to 1/4 turn.
  • Slowly open the cylinder valve by turning the handle counterclockwise. This allows the oxygen to flow into the regulator.
  • Adjust the regulator by turning the regulator adjustment screw counterclockwise to increase the pressure or clockwise to decrease the pressure until the desired delivery pressure is reached.
  • Attach the oxygen hose to the regulator outlet and ensure it is securely fastened.
  • Turn the regulator adjustment screw counterclockwise to increase the delivery pressure slightly and listen for any hissing sounds that indicate a leak. Use a leak detection solution to check for any leaks around the fittings.
  • Once you have confirmed that there are no leaks, you can use the oxygen for your intended application.

Product Variants

ProductModelMax. Inlet PressureFor Gas TypeInlet ConnectionControl TypeGauges Delivery PressureSupply Pressure GaugeInlet GaugeOutlet Connection TypePrice
HARRIS 425-125-540 Regulator Oxygen | AE4JGJ 5KZ43 425-125-5403000 psiOxygenCGA 540T-Handle200 psig4000 psi4000 psiMale RH€405.99
HARRIS 425-125-346 Regulator Medical Air | AE4JGK 5KZ44 425-125-3463000 psiBreathing AirCGA 346Knob200 psig4000 psi4000 psiMale RH€405.38
HARRIS 425-200-346 Regulator Medical Air | AE4JGL 5KZ45 425-200-3463000 psiBreathing AirCGA 346T-Handle400 psig4000 psi4000 psiMale RH€406.88
HARRIS 425-125-580 Regulator 0-125 Psi | AE4JGM 5KZ46 425-125-5803000 psiArgon, Helium, NitrogenCGA 580T-Handle200 psig4000 psi4000 psiMale RH€420.38
HARRIS 425-200-580 Regulator 0-200 Psi | AE4JGN 5KZ47 425-200-5803000 psiArgon, Helium, NitrogenCGA 580T-Handle400 psig4000 psi4000 psiMale RH€411.73
HARRIS 425-125-320 Regulator 0-125 Psi | AE4JGP 5KZ48 425-125-3203000 psiCarbon DioxideCGA 320T-Handle200 psig4000 psi4000 psiMale RH€408.84
HARRIS 425-50-540 Regulator Oxygen | AE4JGQ 5KZ50 425-50-5403000 psi---60 psig4000 psi4000 psiMRH€430.26

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

HARRIS 425-200-540 Gas Regulator, Single Stage, CGA 540 Inlet, 9/16 in -18 M RH Outlet, 200 psig, Oxygen
€409.27 /unit