FREE delivery on orders over €150
GENERAL ELECTRIC THQB32100 Circuit Breaker 3pole 100a Thq 240v 10ka | AC9PWC 3HXX5

GENERAL ELECTRIC THQB32100 Circuit Breaker 3pole 100a Thq 240v 10ka

Item: AC9PWCModel: THQB32100Cross Ref: 3HXX5
7 In Stock

Ships within 2 days via

€889.58
10.00% off
€800.62 /unit
Add To Cart
Request a Quote

Payment

Product Specifications:

Item Bolt On Circuit Breaker
Ac Voltage Rating 120/240V AC
Air @ 120v Ac 10 kA
Air @ 240vac 10 kA
Amps 100A
Circuit Breaker Actuator Toggle
Circuit Breaker Mounting Style Bolt On
Circuit Breaker Type Standard
Dc Voltage Not Rated
Dc Voltage Rating Not Rated
Depth 3.28"
For Use With Lighting Panels, Load Centers
Frame 100A/THQ
Length 3.53"
Max. Air Rating 10kA
Max. Air Rating 10 kA At 120/240V AC
Max. Wire Size 1/0 AWG
Min. Wire Size 6 AWG
Number Of Poles 3
Phase Three
Terminal Connection Lug
Terminal Connection Type Lug
Width 1"

Shipping Info:

Ship weight (kg) 0.5
Ship height (cm)8.33
Ship length (cm)6.03
Ship width (cm)7.62
HS code8536200020
Country of OriginUS

Product Details:

General Electric THQB32100 circuit breaker is used in electrical distribution systems to protect electrical circuits and equipment from overcurrents, short circuits and electrical faults. They are valuable in data centres, energy generation and power distribution applications.

Features:

  • General Electric THQB32100 circuit breaker features a thermal-magnetic trip mechanism to deliver long-time and instantaneous current limiting functions against faulty currents.
  • It is integrated with a bolt-on mounting facility to minimise installation downtime in reverse-feed applications.
  • This circuit breaker is rated at 240V and calibrated at an ambient temperature of 40 degrees C.

Compatible Accessories:

  • General Electric EY3B Mounting Base: The brand's EY3B mounting base helps users to easily install this MCCB.

Frequently Asked Questions:

Q. What is the difference between MCCBs and MCBs (Miniature Circuit Breakers)?

A. MCCBs are designed for higher current levels, whereas MCBs are used for lower current levels.

Q. Can I reset this General Electric THQB32100 circuit breaker after tripping?

A. Yes, you can manually reset it after a trip event, provided that the fault condition has been rectified and the circuit breaker is in 'off' position. Resetting the MCCB restores the contacts to the closed position, allowing the circuit to be energised again.

Q. What is the difference between a circuit breaker and a fuse?

A. A circuit breaker has an internal switch that trips when there is excess current, whereas a fuse is a metal piece that melts when excess current overloads the circuit.

Product Variants

ProductModelNumber Of PolesAc Voltage RatingAmpsCircuit Breaker TypePhaseAic RatingMin. Wire SizeMax. Wire SizePrice
GENERAL ELECTRIC THQB32020 Circuit Breaker 3pole 20a Thq 240v 10ka | AC9PVV 3HXW3 THQB320203120/240V AC20AStandardThree-14 AWG8 AWG€659.23
GENERAL ELECTRIC THQB32030 Circuit Breaker 3pole 30a Thq 240v 10ka | AC9PVW 3HXW5 THQB320303120/240V AC30AStandardThree-14 AWG8 AWG€685.28
GENERAL ELECTRIC THQB32070 Circuit Breaker 3pole 70a Thq 240v 10ka | AC9PWA 3HXX2 THQB320703120/240V AC70AStandardThree-8 AWG1/0 AWG€805.86
GENERAL ELECTRIC THQB32080 Circuit Breaker 3pole 80a Thq 240v 10ka | AC9PWB 3HXX3 THQB320803120/240V AC-StandardThree-6 AWG1/0 AWG€1,055.71
GENERAL ELECTRIC THQB2170ST1 Bolt On Circuit Breaker Thqb 70 Amp 240vac 2p 10kaic@120v | AG8VZV THQB2170ST12240V AC70A--10 kAIC @ 120V---
RFQ
GENERAL ELECTRIC THQB2180 Bolt On Circuit Breaker Thqb 80 Amp 240vac 2p 10kaic@240v | AG8VZW THQB21802120/240V AC80AStandardSingle10 kAIC @ 240V6 AWG1/0 AWG€551.92
GENERAL ELECTRIC THQB2180ST1 Bolt On Circuit Breaker Thqb 80 Amp 240vac 2p 10kaic@120v | AG8VZX THQB2180ST12240V AC80A--10 kAIC @ 120V--€299.83
RFQ

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

GENERAL ELECTRIC THQB32100 Circuit Breaker 3pole 100a Thq 240v 10ka
€889.58 /unit