Product Specifications:

Item Data Logger
Ac Adapter No
Ac Voltage Accuracy Not Applicable
Accuracy -1% to +1%
Alarm No
Amps Accuracy Not Applicable
Batteries Included Yes
Battery Chemistry Lithium
Battery Life 6 Months
Battery Run Time 6 Months
Battery Size Dl123
Calibration Certificate Not Included
Calibration Certificate Type Available Separately
Current Channels Not Applicable
Data Logger Type Pressure
Dc Current Accuracy Not Applicable
Dc Voltage Accuracy Not Applicable
Diameter 3 1/2"
Digital Display Screen Type LCD
Digital Readout Yes
Features Built In Diaphragm Seal, Displays 7 Different Pressure Units, Saves Data To Optional Flash Card
Height 2 4/5"
Interface Usb
Manufacturer Warranty Length 1 yr.
Max. Dc Voltage Measured Not Applicable
Max. Pressure Measured 100 psi
Max. Relative Humidity Measured Not Applicable
Maximum Ac Current Not Applicable
Maximum Ac Voltage Measured Not Applicable
Maximum Dc Current Measurement Not Applicable
Maximum Dew Point Measured Not Applicable
Maximum Operating Temperature °f 158°F
Maximum Sampling Rate 24 hrs.
Maximum Temperature Measured Degrees C Not Applicable
Maximum Temperature Measured Degrees F Not Applicable
Min. Amps Measurement Not Applicable
Min. Dc Voltage Measured Not Applicable
Min. Relative Humidity Measured Not Applicable
Min. Temp. Measured Not Applicable
Min. Temp. Measured Degrees C Not Applicable
Minimum Ac Voltage Measured Not Applicable
Minimum Dew Point Measured Not Applicable
Minimum Operating Temperature °f -4°F
Minimum Sampling Rate 1 sec.
No. Of Batteries Required 1
No. Of Voltage Channels Not Applicable
Number Of Records Stored 64768
Overall Dia. 3 1/2"
Overall Diameter 3.5"
Overall Height 3 1/2"
Overall Width 3 1/2"
Parameters Measured Pressure
Power Source Battery
Pressure 0 psi to 100 psi
Pressure Range 0 psi to 100 psi
Remote Probe No
Resistance Properties Waterproof
Sample Point Storage 64 KB
Software Options Software Available Separately
Software Required 4LB62
Special Features Built In Diaphragm Seal, Displays 7 Different Pressure Units, Saves Data To Optional Flash Card
Time Intervals 1 sec. to 24 hrs.
Type Pressure
Waterproof Yes

Shipping Info:

Ship weight (kg) 0.61
Ship height (cm)15.49
Ship length (cm)22.35
Ship width (cm)20.32
HS code9031808085
Country of OriginUS

Product Details:

Dickson PR125 data logger allows users to set specific start times for data collection, ensuring accurate recording of temperature, humidity or other environmental variables over designated intervals. It is ideal for pharmaceuticals, healthcare, laboratories and food storage facilities.

Features:

  • Dickson PR125 data logger has a pressure range from 0 to 100 psi, ensuring precise pressure monitoring is critical.
  • It comes with a remarkable accuracy of +/-1% of full scale, guaranteeing reliable and highly accurate data collection for quality control processes.
  • This data logger offers a comprehensive digital readout, allowing users to easily access and interpret data directly on the device without the need for additional tools or software.
  • It is equipped with a built-in diaphragm seal for preventing pressure fluctuations.
  • It features the ability to display data in 7 different pressure units, providing flexibility for users who may need varied units for specific applications.
  • This data logger has a waterproof design, ensuring its resilience in environments with moisture or potential exposure to liquids.
  • It saves data to an optional flash card, facilitating convenient data storage and retrieval for further analysis, compliance reporting, or archival purposes.

Compatible Accessories:

  • Dickson A016 DicksonWare Software: This software facilitates seamless communication with the data logger for enabling users to effortlessly retrieve, analyse and manage the collected data with an intuitive interface. This DicksonWare software simplifies the process of configuring the data logger, setting custom parameters and downloading stored information for in-depth analysis.

Frequently Asked Questions:

Q. How do I interpret the data trends displayed by Dickson PR125 data logger?

A. The software provides graphical representations to help users easily interpret data trends over time.

Q. What is the battery life of Dickson PR125 data logger?

A. The battery life is approximately 6 months at a 5-minute sample rate. To extend it, consider adjusting the sample rate or use an AC adapter.

Q. What is the maximum storage capacity of this data logger?

A. Dickson PR125 can store up to 64000 sample points.

Product Variants

ProductModelPressurePressure RangeNumber Of Records StoredHeightDigital ReadoutAlarmAc AdapterWaterproofPrice
DICKSON PR325 Data Logger, Delayed Start, 0 To 300 psi | AC3HML 2TLA4 PR3250 psi to 300 psi0 psi to 300 psi647682 4/5"YesNoNoYes€749.62
DICKSON PR525 Data Logger, Delayed Start, 0 To 500 psi | AC3HMM 2TLA5 PR5250 psi to 500 psi0 psi to 500 psi647682 4/5"YesNoNoYes€899.03

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DICKSON PR125 Data Logger, Delayed Start, 0 To 100 psi
€749.62 /unit