Product Specifications:
| Item | Replacement Filter Kit |
| Compatible With Grainger Part No | 59JW36, 5CFL7, 9AL76 |
| Compatible With Manufacturer Part Number | BB100-CO |
| Compatible With Series | Breather Boxes |
| Fits Brand | Air Systems |
| For Use With | Breather Box Air Filtration |
| Included | A Replacement Filter, C Replacement Filter, D Replacement Filter |
| Series | BB100 Series |
| System Type | SAR System |
Shipping Info:
| Ship weight (kg) | 1.8 |
| Ship height (cm) | 15.24 |
| Ship length (cm) | 30.48 |
| Ship width (cm) | 25.4 |
| HS code | 8421990180 |
| Country of Origin | US |
Product Details:
Air Systems International BB100-FK replacement filter kit is used with the brand's BB100 Series in industrial settings, construction sites, laboratories and manufacturing facilities to remove harmful particles, dust, fumes and contaminants from the air. It helps to ensure that the air being breathed in by workers or individuals is clean and free from potentially hazardous substances.
Features:
- It comes with A, C and D replacement filters for replacing the existing filters.
- This filter kit is equipped with pre-filters to capture large particles and debris.
- It has HEPA filters for removing small particles, bacteria, viruses, mould spores and microscopic pollutants.
Compatible Accessories:
- Air Systems International BB100-CO Filtration Panels: These BB100 filter kits fit into the portable filtration panels to eliminate water, oil, gases, vapours & particulates and monitor carbon monoxide levels.
Standards and Approvals:
- Army Corps of Engineers EM385-1-1
- CSA Z180.1
- OSHA 29 CFR 1910.134
Frequently Asked Questions:
Q. Why is SAR breathing equipment required?
A. An SAR (supplied-air respirator) breathing equipment is a type of personal protective equipment (PPE) for continuously supplying workers with safe breathing air in an environment having contaminated or harmful air.
Q. What are the uses of portable filtration panels?
A. Portable filtration panels feature filtration equipment in a hard-sided case for moving them from one location to another. These filtration panels install between the air cylinder / compressor & a worker's airline to remove contaminants like particulates, water, oil, vapours and gases and supply safe breathable air.
Q. How do I install this replacement filter kit?
A.
- Ensure the system is powered off and disconnected from any power sources for safety.
- Locate and remove the cover or panel to access the filter compartment.
- Carefully remove the old filters, noting their orientation and order.
- Dispose of the old filters properly according to local regulations.Install pre-filters if included, before the HEPA filters.
- Align and insert the HEPA filters securely into their designated slots.
- Replace and secure the filter compartment cover or panel.
- Turn on the air filtration system and check for proper operation.
Q. What factors should be considered while choosing a replacement filter kit?
A.
- Consider the appropriate filter type that is compatible with your HVAC system.
- Determine the correct filter size by measuring or consulting your HVAC system manual.
- Check the MERV rating of the replacement filter and choose one that suits your air quality needs.
- Assess the airflow resistance of the filter to ensure it allows sufficient airflow for your HVAC system.
- Evaluate the maintenance requirements, such as regular replacement or cleaning, based on your preference and time availability.
- Identify specific indoor air quality goals and select a filter with features like activated carbon if needed.
- Consider energy-efficient filters that can help reduce energy consumption and minimize pressure drop.
- Determine your budget for replacement filters, considering long-term cost implications.
Q. How do I determine that the air filter needs to be changed?
A.
- Check if the air filter appears visibly dirty, clogged or covered in dust and debris.
- Refer to the manufacturer's recommendations for the expected lifespan of the filter.
- Notice if there is a significant decrease in airflow from the vents.
- Look for signs of decreased efficiency, such as longer cycles, reduced airflow or increased energy consumption.
- Take note of increased allergy symptoms, respiratory issues, or frequent coughing.
- Consider more frequent checks and replacements if you have pets that shed hair or dander.
- Be aware of increased dust and debris during construction or renovation projects.
- Check if the filter has built-in indicators that change colour or show visual cues.
- Incorporate air filter replacement into your regular HVAC system maintenance schedule.
Product Variants
| Product | Model | For Use With | Compatible With Manufacturer Part Number | Compatible With Grainger Part No | System Type | Compatible With Series | Fits Brand | Series | Price | |
|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BB50-FK | BB50 Series Models | BB50-CO | 5CFL6, 8F983, 8W722, 9AL76 | SAR System | Breather Boxes | Air Systems | - | €295.46 | |
![]() |
BB30-FK | Breather Box Air Filtration | BB15-CO, BB30-CO | 33L378, 59JW35, 8W722 | SAR System | Breather Boxes | Air Systems | - | €305.87 | |
![]() |
BB75-FK | BB75 Series Models | - | - | - | - | - | - | €349.06 | |
![]() |
BB60-FK | - | - | - | - | - | - | - | €143.55 |
Explore Products
- SMC VALVES CG1BN80TN-125Z-XC6 Round Body Cylinder
- AMERICAN FILTER CO AFC-EPH-104-9000S-1p-5753 AFC Brand AFC-EPH-104-9000S
- LCN 4040XP-HW/PA RH US3 Surface Mounted Closer, Hydraulic, Heavy Duty, Hold Open, Right Hand
- HUMBOLDT HC-3000.1 Sensor
- CRESCENT ccw1-05 5/16 Inch 12 Point Combination Wrench
- ANVIL 0320201213 Steel Pipe Half Coupling, XH, Black, Taper Tapped, 1/4 Inch Nominal Size
- SMC VALVES CKZ2N50TF-90DP-AA422XXXXX Arm For Clamp Cylinder
- EATON A201K5CE Motor Control Contactor, Non-Reversing, 270A, 3-Pole, Size 5, 600V At 60 Hz Coil
Explore More
- BUCKEYE
- KEYSHAFT
- LAB SAFETY SUPPLY
- SPEC
- RADIANT
- OEM Replacement Motors
- Negative Air Machine Accessories
- Wire Marking Labels
- Binding Screws
- DESTACO 202 Series Vertical Hold Down Clamps
- PHILIPS ADVANCE Ballast Ignitors
- ANSELL 29-865 Alphatec Medium Duty Unsupported Neoprene Gloves
- GLOBE SCIENTIFIC Pierceable Plug Stoppers, For 13 mm Tubes
- RUD CHAIN B-ABA Lifting Points
- PARKER Union Tee, Flare Thread
- MOON AMERICAN Heavy Duty Fire Hose Reel
- QMARK Spst Thermostat
- MARTIN SPROCKET 3/8 Inch Drive 6 Point Impact Socket Sets
- APPROVED VENDOR #4-40 Fully Threaded Standard Hex Passivated Stainless Steel Flat Machine Screws
Contact us