EATON RG Series Electronic Molded Case Circuit Breakers, RG Frame


Eaton RG Series circuit breakers are electrical protection devices designed to protect electrical circuits and equipment from damage caused by overcurrent and short circuit conditions. They are offered in single-pole and double-pole configurations.

Filter
StyleModelNumber Of PolesVoltageTypeCircuit Breaker TypePrice
A
RGH320039B22E
----€75,447.43
B
RGH216038E
----€54,725.61
B
RGH216032E
2480V AC-RG€47,896.90
B
RGH220038E
2--RG€64,156.51
B
RGH220032E
2480V AC-RG€53,965.88
C
RGC320T94XWP49
3600V AC-RG€85,489.66
A
RGH316032B20ZGM
3--RG-
RFQ
A
RGH316032B20ZGE
3--RG-
RFQ
A
RGH316032B20E
3-Complete BreakerRG€53,817.43
C
RGC316038B20MC
3600V AC-RG-
RFQ
C
RGC320T95WP49
3600V AC-RG€90,336.07
C
RGC325T95XWP53
3600V AC-RG€113,878.48
C
RGC320T96WP49
3600V AC-RG€95,330.99
C
RGC325032B20ZGM
3600V AC-RG-
RFQ
C
RGC325035B20M
3600V AC-RG-
RFQ
C
RGC325032B20E
3600V AC-RG€87,471.89
C
RGC325033B20E
3600V AC-RG€82,669.08
C
RGC320T96XWP49
3600V AC-RG€91,741.98
C
RGC325T94WP53
3600V AC-RG€117,319.01
C
RGC325T96XWP53
3600V AC-RG-
RFQ
C
RGC325039ZGE
3600V AC-RG€115,659.88
C
RGC325036ZGE
3600V AC-RG-
RFQ
C
RGC325038ZGE
3600V AC-RG€102,893.19
C
RGC325039B21ZGE
3600V AC-RG-
RFQ
C
RGC325039B20ZGM
3600V AC-RG-
RFQ
C
RGC325039M
3600V AC-RG-
RFQ
C
RGC325T83WP53
3600V AC-RG-
RFQ
C
RGC325T82WP53
3600V AC-RG€89,148.48
C
RGC325032E
3600V AC-RG€86,362.86
C
RGC325T85WP53
3600V AC-RG€114,489.75
C
RGC325T85XWP53
3600V AC-RG€109,800.47
C
RGC325T92WP53
3600V AC-RG€89,148.48
C
RGC325T93WP53
3600V AC-RG€89,148.48
C
RGC325T96WP53
3600V AC-RG€123,370.52
C
RGC325T94XWP53
3600V AC-RG€112,638.48
C
RGC325T91WP53
3600V AC-RG€89,148.48
C
RGC325032M
3600V AC-RG-
RFQ
C
RGC325035B22M
3600V AC-RG€84,843.45
C
RGC325032B20ZGE
3600V AC-RG-
RFQ
C
RGC325039B22ZGE
3600V AC-RG€105,748.64
C
RGC325038B20ZGM
3600V AC-RG-
RFQ
C
RGC325039B21E
3600V AC-RG-
RFQ
C
RGC325039B22ZGM
3600V AC-RG€105,748.64
C
RGC325039B21ZGM
3600V AC-RG-
RFQ
C
RGC325039B22E
3600V AC-RG€103,225.00
C
RGC325T52WP53
3600V ACDigitrip 510RG-
RFQ
C
RGC325039ZGM
3600V AC-RG€115,659.88
C
RGC325038ZGM
3600V AC-RG€102,893.19
C
RGC325T84XWP53
3600V AC-RG€108,630.33
C
RGC325T86XWP53
3600V AC-RG€114,699.33
A
RGH316032EC
3-Complete BreakerRG€24,384.34
A
RGH316032E
3-Complete BreakerRG€21,800.85
A
RGH316032MC
3-Complete BreakerRG€57,965.28
A
RGH316032ZGE
3-Complete BreakerRG€55,214.59
C
RGC325038M
3600V AC-RG€100,360.80
C
RGC325036B22M
3600V AC-RG€89,209.61
C
RGC325039B20E
3600V AC-RG-
RFQ
C
RGC325033B20M
3600V AC-RG-
RFQ
C
RGC325033E
3600V AC-RG€81,542.61
C
RGC325033M
3600V AC-RG€81,542.61
C
RGC325032ZGE
3600V AC-RG€88,886.52

Working Mechanism

  • Eaton RG Series circuit breakers use the trip mechanism to detect current flow exceeding rated capacity.
  • The trip mechanism then opens breaker contacts to break the circuit and stop the flow of electricity.
  • They then prevent damage to electrical devices & wiring and prevent the risk of fire.
  • They are reset manually once the issue is resolved to ensure electrical circuits are protected and provide means of quickly restoring power when needed.

Features

  • Eaton RG Series circuit breakers feature a compact design for easy installation in tight spaces.
  • These circuit breakers have a self-test feature for added safety and proper functioning.
  • They feature imperial mounting hardware for secure installation.
  • These circuit breakers offer electrical LS / LSI / LSIG trips to protect the low voltage systems from current overloads and short circuits.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the amperage and voltage rating of these Eaton RG Series circuit breakers?

1600A, 600VAC.

How to install these circuit breakers?

  • Before starting the installation, turn off the main power to the electrical panel.
  • Check the panel to ensure enough space for the new breaker.
  • Fit the breaker into the panel and secure it in place with the appropriate hardware so that the breaker should click into place when fully installed.
  • Connect the breaker to the electrical system using the appropriate wiring connections.
  • Once the breaker is connected, turn on the main power to the electrical panel.
  • Test the breaker by turning on the breaker and observe its performance.
  • If it works correctly, the breaker is installed and ready for use.

We are here to help!

Looking for a part not listed here?