EATON Power Xpert 1300 Series Meters
Eaton 1300 Series Power Xpert meters are used for measuring electrical parameters such as voltage, current, power, energy and frequency.
Filter
| Style | Model | Amps Sensor Input | Height | Type | Waveform Capture Sampling Rate | Voltage | Ansi % Revenue Accuracy | Communications | Memory | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | PXM1300TA41-1 | 1A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,242.75 | |
| A | PXM1300TA11-1 | 1A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300MA41-1 | 1A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,551.50 | |
| A | PXM1300MA11-1 | 1A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,397.12 | |
| A | PXM1300TA15-1 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| B | PXM1300MA15-1 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| B | PXM1300MA15 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,949.88 | |
| B | PXM1300TA15 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €3,917.52 | |
| B | PXM1300MA45-1 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300TA45-1 | 5A | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,242.75 | |
| A | PXM1300TA13-1 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300TA43-1 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,047.90 | |
| B | PXM1300TA13 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300MA43-1 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,551.50 | |
| A | PXM1300MA13-1 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,397.12 | |
| A | PXM1300MA13 | 333 mV | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300MA1R-1 | Rogowski Coil | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,397.12 | |
| A | PXM1300TA1R-1 | Rogowski Coil | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | - | RFQ
|
| A | PXM1300TA4R-1 | Rogowski Coil | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,047.90 | |
| A | PXM1300MA4R-1 | Rogowski Coil | 4" | Meter | 512/cycle | 100-415V AC/100-300V DC | C12.20 (0.2) | Modbus RTU (RS - 485) | 8 Megabytes | €4,551.50 |
Features
- These Eaton 1300 Series Power Xpert meters have 16 MB of data storing capacity.
- They enable recording of the majority of the metering parameters in three assignable historical logs.
- They feature real-time metering of current, phase voltage, line voltage, apparent power, reactive power, power factor and frequency.
- These meters are available in voltage ratings of 100 - 415VAC / 100 - 300VDC.
- They can monitor voltage and current waveform.
- These meters can log sag / dips and swell (voltage) of power quality event logging.
- They further feature over / under limit alarms based on user-defined thresholds, which can help to alert users to potential issues or problems.
Standards and Approvals
- ANSI
Frequently Asked Questions
What is the operating temperature of Eaton 1300 Series Power Xpert meters?
-25 to 70 degrees C.
How can I communicate with Eaton 1300 Series Power Xpert meters?
These meters have built-in communications options such as Modbus, Ethernet, and BACnet.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- KEYSHAFT
- SOLA/HEVI-DUTY
- TRAXION
- ACURITE
- SITOP
- Hand Lamps
- Letters and Numbers
- Vector Motors
- Galvanized Pipe
- Solar Panels
- OIL SAFE Premium Pump Body Collars
- IRONCLAD Kong Dexterity Supergrip Gloves
- ANSELL 02-100 Alphatec Highly Chemical Resistant Gloves
- DEWALT Protector Safety glasses
- PYRAMEX Goliath Full Frame Eyewears
- SCOTSMAN Temperature Sensor Ice Makers
- GRAINGER Quick Change Discs
- APPROVED VENDOR M8 x 1.25 Fully Threaded Grade 18-8 Stainless Steel Threaded Rods
- HAMMOND 2UD CP F Series Mild Steel Two Door Floor Mount Disconnect Enclosures
- MIDWEST Machine Screws, Slotted Drive, Nylon