EATON Power Xpert 1100 Series Meters
Eaton 1100 Series Power Xpert meters are advanced multi-function meters used for measuring electrical parameters such as voltage, current, power, energy and frequency. They can be used for energy management, monitoring and control.
Filter
| Style | Model | Height | Amps Sensor Input | Voltage | Type | Ansi % Revenue Accuracy | Communications | Memory | Power Quality Analysis | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | PXM1100MA13 | 4 1/2" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,358.83 | |
| B | PXM1100MA15 | 4" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,460.24 | |
| A | PXM1100TA13 | 4" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,058.20 | |
| A | PXM1100TA14 | 4" | - | 100-415V AC/100-300V DC | Meter | - | - | - | - | €2,592.92 | |
| A | PXM1100TA41-1 | 4" | 1A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100TA11-1 | 4" | 1A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,146.69 | |
| A | PXM1100MA44 | 4" | - | 20-60V DC | Meter | - | - | - | - | €3,142.88 | |
| A | PXM1100MA45-1 | 4" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100MA13-1 | 4" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,460.24 | |
| C | PXM1100MA14 | 4" | - | 100-415V AC/100-300V DC | Meter | - | - | - | - | - | RFQ
|
| A | PXM1100MA11-1 | 4" | 1A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,460.24 | |
| A | PXM1100TA44 | 4" | - | 20-60V DC | Meter | - | - | - | - | - | RFQ
|
| A | PXM1100TA43-1 | 4" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,303.47 | |
| A | PXM1100TA15-1 | 4" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,146.69 | |
| A | PXM1100TA4R-1 | 4" | Rogowski Coil | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,303.47 | |
| A | PXM1100TA45-1 | 4" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100TA44-1 | 4" | - | 20-60V DC | Meter | - | - | - | - | - | RFQ
|
| B | PXM1100TA15 | 4" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100MA43-1 | 4" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100TA14-1 | 4" | - | 100-415V AC/100-300V DC | Meter | - | - | - | - | €2,592.92 | |
| A | PXM1100TA13-1 | 4" | 333 mV | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,146.69 | |
| A | PXM1100MA44-1 | 4" | - | 20-60V DC | Meter | - | - | - | - | - | RFQ
|
| A | PXM1100MA4R-1 | 4" | Rogowski Coil | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,614.60 | |
| A | PXM1100MA1R-1 | 4" | Rogowski Coil | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| A | PXM1100MA41-1 | 4" | 1A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | - | RFQ
|
| C | PXM1100MA14-1 | 4" | - | 100-415V AC/100-300V DC | Meter | - | - | - | - | €2,715.18 | |
| A | PXM1100TA1R-1 | 4" | Rogowski Coil | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,146.69 | |
| A | PXM1100MA15-1 | 5" | 5A | 100-415V AC/100-300V DC | Meter | C12.20 (0.2) | Modbus RTU (RS - 485) | 4 Megabytes | K-Factor & Crest Factor | €2,460.24 |
Features
- They feature real-time metering of current, phase voltage, line voltage, apparent power, reactive power, power factor and frequency.
- They can be operated at temperatures ranging from -25 to 70 degrees C.
- These meters feature over / under limit alarms based on user-defined thresholds, which can help to alert users to potential issues or problems.
Frequently Asked Questions
How can I communicate with Eaton 1100 Series Power Xpert meters?
These meters offer built-in communications options such as BACnet, Modbus and Ethernet.
What is the storage capacity of these meters?
These meters have data storage capacity of 8 MB.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- LARSON ELECTRONICS LLC
- SNYDER INDUSTRIES
- MEM CO
- SAF-HOLLAND
- Welding Hose
- Wire Shelving Accessories
- AC Current Line Splitters
- Manual Balancing Valves
- Strainer
- HI TEMP Welding Pipe Wrap
- NEWSTRIPE AeroVent Aerosol Can Recycling Systems
- AKRO-MILS Insight Series Ultra Clear Polycarbonate Bins
- ANSELL Class 00 Electrical Gloves, 11 Inch, Red
- ANVIL 010CTG Series Light Duty Copper Ring Hangers
- METRO Display Shelves
- VERMONT GAGE Car X Go/NoGo Reversible Assemblies
- ANVIL Standard Bull Plugs
- SPEARS VALVES PVC True Union 2000 Industrial Vertical 3-Way Ball Valves Regular Style, Flanged, FKM
- 3M 471 Vinyl Tapes, Green