EATON Enclosed Circuit Breakers


Eaton enclosed circuit breakers are used to protect electrical equipment from damage caused by overcurrents or short circuits.

Filter
StyleModelAmpsTypeVoltagePrice
A
SGDN100
---€566.67
B
SCNDN1200
-Enclosure-€3,393.17
C
FFD100E
15-100ACircuit Breaker Enclosure-€706.21
D
SFD100E
15-100ACircuit Breaker Enclosure-€677.10
E
RFDN100E
15-100ACircuit Breaker Enclosure-€1,837.30
F
FFDN100
15-100ACircuit Breaker Enclosure--
RFQ
G
SFDN100
15-100ACircuit Breaker Enclosure--
RFQ
H
FFDN225
125-225ACircuit Breaker Enclosure-€660.11
I
SFDN225
125-225ACircuit Breaker Enclosure--
RFQ
J
FJDN250
125-250ACircuit Breaker Enclosure-€1,258.85
K
SJDN250
125-250ACircuit Breaker Enclosure--
RFQ
L
SKDN400
125-400ACircuit Breaker Enclosure-€1,174.97
M
RKDN400
125-400A--€3,879.60
N
FKDN400
125-400A---
RFQ
J
AR1HA1NL2R-00LO
125AARMS Enclosed Circuit Breaker600V-
RFQ
O
SLG630E
250-600ACircuit Breaker Enclosure-€1,706.57
O
SLG630
250-600ACircuit Breaker Enclosure-€2,381.09
J
AR2HA1NL2R-00LO
250AARMS ECB Demo Switch600V-
RFQ
P
SLDN600
300-600A--€1,950.85
Q
RNDN1200
400-1200A--€5,446.31
B
SNDN1200
400-1200A--€2,705.01
J
AR3HA1NL2R-00LO
400AARMS Enclosed Circuit Breaker600V-
RFQ
J
AR4HA1NL4R-00LO
600AARMS Enclosed Circuit Breaker600V-
RFQ
J
AR5HA1NL7R-00LO
800AARMS Enclosed Circuit Breaker600V-
RFQ
J
AR6HB1NL7R-00LO
1200AARMS Enclosed Circuit Breaker600V-
RFQ

Features

  • These MCCBs have a Digitrip 310+ trip unit to monitor and trip to prevent damage to the electrical equipment.
  • They come in 3 pole configurations to maintain balanced power distribution and decrease the risk of power quality issues.
  • These enclosed circuit breakers are available in 55 to 1200A current ratings.
  • They have a three-positioned handle to indicate On / Off / reset / tripped positions.
  • These circuit breakers are available in 1-phase and 3-phase configurations for controlling single and multiple connections.

Standards and Approvals

  • UL
  • CSA

Frequently Asked Questions

What is the maximum operating voltage of Eaton enclosed circuit breakers?

600VAC.

What is the significance of the Digitrip RMS 310 trip in these circuit breakers?

The Digitrip RMS 310 trip units utilise Eaton's microprocessor-based intelligence to provide true RMS sensing, permitting increased accuracy and reliable system protection. This unit is front-adjustable and has an optional local display of the current and cause of the trip.

We are here to help!