EATON EGSDC Series DC Circuit Breakers


Eaton EGSDC Series DC circuit breakers protect DC electrical systems from damage caused by overcurrents and short circuits. They are ideal for the power generation, transportation, telecommunication and marine industries.

Filter
StyleModelNumber Of PolesCircuit Breaker TypeVoltagePrice
A
EGSDC3080FFG
3-347/600V AC€1,943.04
A
EGSDC3045FFW
3EG347/600V AC€1,567.72
A
EGSDC3070FFW
3EG347/600V AC€1,764.70
A
EGSDC3035FFW
3EG347/600V AC€1,699.94
A
EGSDC3090FFG
3EG347/600V AC€1,791.93
A
EGSDC3060FFW
3-347/600V AC€1,567.72
A
EGSDC3050FFG
3EG347/600V AC€1,729.46
A
EGSDC3040FFW
3EG347/600V AC€1,647.45
A
EGSDC3060FFG
3EG347/600V AC€1,594.98
A
EGSDC3050FFW
3EG347/600V AC€1,567.72
A
EGSDC3040FFG
3EG347/600V AC€1,594.98
A
EGSDC3100FFW
3EG347/600V AC€1,854.44
A
EGSDC3045FFG
3EG347/600V AC€1,594.98
A
EGSDC3035FFG
3EG347/600V AC€1,594.98
A
EGSDC3025FFW
3EG347/600V AC€1,567.72
A
EGSDC3030FFG
3EG347/600V AC€1,594.98
A
EGSDC3080FFW
3EG347/600V AC€1,764.70
A
EGSDC3030FFW
3EG347/600V AC€1,567.72
A
EGSDC3100FFG
3-347/600V AC€1,791.93
A
EGSDC3070FFG
3EG347/600V AC€1,943.04
A
EGSDC3025FFG
3EG347/600V AC€1,594.98
A
EGSDC3090FFW
3EG347/600V AC€1,764.70

Working Mechanism

  • These EGSDC Series DC circuit breakers incorporate both fixed thermal and magnetic trips.

Fixed Thermal Trips

  • Fixed thermal trips are based on the heat generated by the current passing through the circuit.
  • The trip unit contains a bimetallic strip sensitive to temperature changes.
  • As the current increases, the bimetallic strip heats up and bends, triggering the breaker to trip.

Fixed Magnetic Trips

  • Fixed magnetic trips use the strength of the magnetic field created by the current passing through the circuit.
  • The trip unit contains an electromagnet sensitive to changes in magnetic field strength.
  • As the current increases, the magnetic field strength increases and when it reaches a certain level, it triggers the breaker to trip.

Features

  • Eaton EGSDC Series DC circuit breakers have a contact design that pushes away contact arms for protection during false currents.
  • They have thermal-magnetic trip units for protection against overloads and short circuits.
  • These circuit breakers feature a three-pole configuration to protect all three phases in 3-phase electrical systems.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the difference between a circuit breaker and a fuse?

A circuit breaker can be reset and reused, while a fuse must be replaced once it has blown.

How to choose the right circuit breaker for a specific application?

Choosing the right circuit breaker for a specific application depends on the electrical load requirements of the circuit, the voltage & frequency of the electrical supply and the environment in which the circuit breaker will be used.

How to maintain these Eaton EGSDC Series DC circuit breakers?

  • Inspect them for damage or wear.
  • Test their tripping function.
  • Check the tightness of electrical connections.

We are here to help!

Looking for a part not listed here?