Eaton ECN06 Class non-reversing combination reversing starters control the operation of electric motors (start / stop). They also control the direction of rotation of the motor and provide overload protection. These starters are used in conveyor systems, crane & hoist systems and other mate...rial handling applications.Read more

Filter
StyleModelHeightFrequencyCoil VoltageNema SizeNema Enclosure RatingPhaseStarter SizeNotesPrice
A
ECN0601CAA-C3
-50/60 Hz-NEMA Size 0NEMA 13--€3,756.56
A
ECN0621EAA
--------€5,238.88
A
ECN0611AAA
--------€2,759.72
B
ECN0618CAA
-50/60 Hz440/460VNEMA Size 1-3--€3,279.02
A
ECN0611EAA
--------€2,759.72
A
ECN0602AAA
7"-110/120V-NEMA 3R-NEMA Size 0-€2,847.26
A
ECN0601CAA-C1
8.3"50/60 Hz440/460VNEMA Size 0NEMA 13--€3,187.50
C
ECN0612BAA
9"-220/240VNEMA Size 1NEMA 3R3--€3,279.02
A
ECN0601CEA-C1
9"50/60 Hz440/460VNEMA Size 0NEMA 13--€3,822.21
B
ECN0631CAA
10"50/60 Hz440/460VNEMA Size 3NEMA 13--€8,667.13
B
ECN0632CAA
11"50/60 Hz440/460VNEMA Size 3NEMA 3R3--€10,515.56
A
ECN0621BAA
12 3/5"50/60 Hz-NEMA Size 2NEMA 13--€5,238.88
A
ECN0611BAA
12 3/5"50/60 Hz220/240VNEMA Size 1NEMA 13--€2,759.72
A
ECN06A1AAA
12 3/5"50/60 Hz110/120VNEMA Size 00NEMA 13--€2,031.48
A
ECN0601AAA
12 3/5"50/60 Hz110/120VNEMA Size 0NEMA 13--€3,656.40
A
ECN0621CAA
12 3/5"50/60 Hz440/460VNEMA Size 2NEMA 13--€5,238.88
A
ECN0621CBA-C1
27.06"50/60 Hz440/460VNEMA Size 2NEMA 13--€7,477.29
A
ECN0621CCA
27.06"50/60 Hz440/460VNEMA Size 2NEMA 13--€7,477.29
A
ECN0621CAA-C1
27.06"50/60 Hz440/460VNEMA Size 2NEMA 13--€6,333.23
A
ECN0621CCA-C1
27.06"50/60 Hz440/460VNEMA Size 2NEMA 13--€8,535.82
A
ECN0611ABA
27.06"50/60 Hz110/120VNEMA Size 1NEMA 13--€3,434.23
A
ECN0611CAA-C1
27.06"50/60 Hz440/460VNEMA Size 1NEMA 13--€3,513.81
A
ECN0621CBA
27.06"50/60 Hz440/460VNEMA Size 2NEMA 13--€6,380.97
A
ECN0611BBA
27.06"50/60 Hz220/240VNEMA Size 1NEMA 13--€3,434.23
A
ECN0601EAA-C1
27.06"60 Hz208VNEMA Size 0NEMA 13--€3,187.50
A
ECN0608CAA
28.98"50/60 Hz440/460VNEMA Size 0NEMA 123--€2,910.94
A
ECN0608CBA-C1
28.98"50/60 Hz440/460VNEMA Size 0NEMA 123--€4,823.04
A
ECN0608CAA-C1
28.98"50/60 Hz440/460VNEMA Size 0NEMA 123--€3,667.02
A
ECN0608BAA
28.98"50/60 Hz220/240VNEMA Size 0-3--€2,910.94
B
ECN0628CHA-C1
28.98"50/60 Hz440/460VNEMA Size 2NEMA 123--€7,845.39
B
ECN0628CJA
28.98"50/60 Hz440/460VNEMA Size 2NEMA 123--€8,078.18
B
ECN0628CBA
28.98"50/60 Hz440/460VNEMA Size 2NEMA 123--€7,226.58
A
ECN0608AAA
28.98"50/60 Hz110/120VNEMA Size 0-3--€2,910.94
B
ECN0618AAA
28.98"50/60 Hz110/120VNEMA Size 1NEMA 123--€3,279.02
B
ECN0614AAA
28.98"50/60 Hz110/120VNEMA Size 1-3--€4,530.56
B
ECN0628CJA-C1
28.98"50/60 Hz440/460VNEMA Size 2NEMA 123--€9,142.67
B
ECN0618AHA
28.98"50/60 Hz110/120VNEMA Size 1NEMA 123--€3,945.59
B
ECN0628CHA
28.98"50/60 Hz440/460VNEMA Size 2-3--€6,731.17
B
ECN0628CCA-C1
28.98"50/60 Hz440/460VNEMA Size 2-3--€9,618.21
B
ECN0628CAA
28.98"50/60 Hz440/460VNEMA Size 2NEMA 123--€6,090.48
B
ECN0628CBA-C1
28.98"50/60 Hz440/460VNEMA Size 2-3--€8,312.97
B
ECN0628BJA
28.98"50/60 Hz220/240VNEMA Size 2NEMA 123--€8,078.18
B
ECN0628CAA-C1
28.98"-440/460VNEMA Size 2-3--€7,166.91
B
ECN0628AAA
28.98"50/60 Hz110/120VNEMA Size 2NEMA 123--€6,090.48
A
ECN0608CBA
28.98"50/60 Hz-NEMA Size 0NEMA 123--€4,041.08
A
ECN0604AAA
28.98"50/60 Hz110/120VNEMA Size 0NEMA 4X3--€3,678.96
B
ECN0618BAA
28.98"50/60 Hz220/240VNEMA Size 1NEMA 123--€3,279.02
B
ECN0618AJA
28.98"50/60 Hz110/120VNEMA Size 1NEMA 123--€5,254.80
B
ECN0628CCA
28.98"50/60 Hz440/460VNEMA Size 2-3--€8,535.82
D
ECN0641AAA
30 1/2"50/60 Hz110/120VNEMA Size 4NEMA 13--€20,692.88
E
ECN0631AAA
30 1/2"50/60 Hz110/120VNEMA Size 3NEMA 13--€8,667.13
B
ECN0638AAA
32 9/25"50/60 Hz110/120VNEMA Size 3NEMA 123-Suitable For Outdoor Application When Properly Installed. Enclosure Is Without Safety Door Interlock.€10,515.56

Working Mechanism

  • When the starter is activated, the contactor closes and allows electrical power to flow to the motor.
  • The overload relay monitors the current being drawn by the motor, and if it detects that the current is too high, it will open the contactor to shut off power to the motor.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the difference between a reversing starter and a soft starter?

A reversing starter is used to reverse the direction of rotation of the motor, whereas the soft starter gradually ramps up the voltage to the motor, reducing inrush current and stress on the motor.

What is the difference between a reversing starter and a motor control centre (MCC)?

A reversing starter is used to control the direction of rotation of a motor, while an MCC is a type of electrical distribution and control system used to control multiple motors and other electrical loads.

What is the difference between a non-combination and a combination reversing starter?

A non-combination reversing starter includes the reversing contactor and overload protection, while a combination reversing starter includes the reversing contactor, overload protection and a forward contactor.