EATON E2NM Type Mining Complete Molded Case Circuit Breakers


Eaton E2NM type mining complete MCCBs are designed to protect against electrical overloads, short circuits and ground faults. They are used in motors, generators and electrical equipment.

Filter
StyleModelNumber Of PolesCircuit Breaker TypeVoltageTypePrice
A
E2NM312MWA13S10
----€43,379.75
A
E2NM3600W
3E2NM250V DC/577/1000V ACSpecialty Complete€24,651.11
A
E2NM3900WU66
3-250V DC/577/1000V ACSpecialty Complete€42,043.31
A
E2NM310WU66
3E2NM250V DC/577/1000V ACSpecialty Complete-
RFQ
A
E2NM312WU66
3E2NM250V DC/577/1000V ACSpecialty Complete€42,043.31
A
E2NM3600WU18
3E2NM250V DC/577/1000V ACSpecialty Complete-
RFQ
A
E2NM312MW
3E2NM250V DC/577/1000V ACSpecialty Complete€40,175.91
A
E2NM310W
3E2NM250V DC/577/1000V ACSpecialty Complete€40,175.91
A
E2NM3800MW
3E2NM250V DC/577/1000V ACSpecialty Complete€24,651.11
A
E2NM3800WU66
3E2NM250V DC/577/1000V ACSpecialty Complete-
RFQ
A
E2NM312MWU66
3E2NM250V DC/577/1000V ACSpecialty Complete€42,043.31
A
E2NM3600WA06U66
3E2NM250V DC/577/1000V ACSpecialty Complete€27,168.40
A
E2NM3800WA06S10
3E2NM250V DC/577/1000V AC--
RFQ
A
E2NM312W
3E2NM250V DC/577/1000V ACSpecialty Complete€40,175.91
A
E2NM3600WU66
3E2NM250V DC/577/1000V ACSpecialty Complete€26,436.09
A
E2NM3800MWU66
3-250V DC/577/1000V ACSpecialty Complete€26,491.01
A
E2NM3800WA06U66
3E2NM250V DC/577/1000V ACSpecialty Complete€27,168.40

Features

  • They feature an interchangeable magnetic trip to protect from short circuits.
  • These MCCBs can be operated without any terminals for enhanced performance.

Frequently Asked Questions

What is the interrupt rating of these MCCBs?

  • 25kAIC at 1000VAC

What is the magnetic trip range of these Eaton E2NM type mining complete MCCBs?

500 - 2500A

How to maintain these MCCBs?

  • Perform routine visual inspections of the circuit breaker to check for any signs of wear or damage. Inspect the case, connections and other components to ensure they are clean and in good condition.
  • Keep the circuit breaker clean and free of debris by wiping it down with a soft & dry cloth. Do not use water or any cleaning agents that could damage the internal components.
  • Lubricate the moving parts of the circuit breaker periodically to ensure smooth operation. Use a high-quality lubricant that is compatible with the materials used in the circuit breaker.
  • Test the circuit breaker's trip function periodically to ensure it is functioning properly. This can be done by using a test kit or by manually tripping the breaker and verifying that it opens the circuit.
  • Calibrate the circuit breaker periodically to ensure it is set to the correct trip settings. This should be done by a qualified technician using specialised equipment.
  • If any parts of the circuit breaker are worn or damaged, they should be replaced promptly to ensure that the circuit breaker continues to function properly.

We are here to help!

Looking for a part not listed here?