EATON DS Type Disconnect Switches


Eaton DS type disconnect switches disconnect a load or supply from the electrical power source. They are used in low-voltage distribution systems as a means of safely isolating equipment for maintenance or repair.

Filter
StyleModelHeightAmpsNotesTypeVoltageNo. Of PolesSwitch TypePrice
A
DS262R
--Terminals Are Suitable For Either Copper Or Aluminum Cable. Suitable For Class J Fuses. UL Listed For Use With Class R Fuses When Fuse Clip Conversion Kits Are Used.----€1,252.39
B
DS363R
-------€2,354.42
C
1230C33G02
1"60A-Disconnect Switch--Type Ds€962.68
C
1230C33G03
1"100A-Disconnect Switch--Type Ds€1,730.98
D
DS26U
5 1/5"-Terminals Are Suitable For Either Copper Or Aluminum Cable. Rated 600 Volts.----€1,099.85
E
DS121R
5 2/5"-600V Ratings Are Suitable For Class J Fuses. UL Listed For Use With Class R Fuses When Fuse Clip Conversion Kits Are Used. Switch Is CSA Listed.----€958.99
A
DS222R
5 2/5"-Terminals Are Suitable For Either Copper Or Aluminum Cable. UL Listed For Use With Class R Fuses When Fuse Clip Conversion Kits Are Used.----€1,125.87
F
1230C28G36
5"60A-Disconnect Switch600V-Type Ds€1,252.39
F
1230C28G34
5"30A-Disconnect Switch600V-Type Ds€958.99
A
DS263
5.3"-Terminals Are Suitable For Either Copper Or Aluminum Cable. Suitable For Class J Fuses.----€1,782.32
G
DS16U
5.3"-Terminals Are Suitable For Either Copper Or Aluminum Cable. Rated 600 Volts.-----
RFQ
H
DS36U
5.3"100ATerminals Are Suitable For Either Copper Or Aluminum Cable. Rated 600 Volts.--3-€2,111.15
E
DS161R
5.3"-Terminals Are Suitable For Either Copper Or Aluminum Cable. Suitable For Class J Fuses. UL Listed For Use With Class R Fuses When Fuse Clip Conversion Kits Are Used.----€1,021.34

Working Mechanism

  • When the switch is in the open position, it disconnects the power supply from the load, effectively shutting off the electrical connection.
  • When the switch is in the closed position, the electrical connection is re-established and power is supplied to the load.

Frequently Asked Questions

What is the difference between fusible and non-fusible DS type disconnect switches?

Fusible switches contain a fuse that will automatically trip and disconnect the power in the event of an overcurrent condition, while non-fusible switches do not have this protection.

How to choose the right DS type disconnect switch?

The choice of switches will depend on the specific requirements of your application, including the voltage & current rating, the type of load and any safety or regulatory requirements.

How do I maintain a DS Type disconnect switch?

  • Clean the terminals periodically.
  • Inspect the switch regularly for any signs of damage or wear.

We are here to help!