Eaton dry-type distribution transformer terminal lug kits are accessories designed to connect cables or wires to the transformer's terminals. They are equipped with all the necessary hardware and instructions to ensure a safe connection and reduce the risk of electrical faults, arching and fire... hazards. These kits are compatible with single and three-phase dry-type distribution transformers. Read more
Filter
| Style | Model | Notes | Type | Height | Price | |
|---|---|---|---|---|---|---|
| A | LKS4 | Terminal Lugs, Cable Range #2 - 600 Kcmil (Qty.29), Hardware, Bolt Size 3/8 - 16 X 2 (Qty. 18) | Terminal Lug Kit | 1.1" | €1,558.08 | |
| B | LKS2 | Terminal Lugs, Cable Range #6 - 250 Kcmil (Qty. 12), Hardware, Bolt Size 1/4 - 20 X 3/4 (Single - Phase, Qty. 8), 1/4 - 20 X 1 - 3/4 (Three - Phase, Qty. 8) | Terminal Lug Kit | 1.1" | €353.85 | |
| C | LKS3 | Terminal Lugs, Cable Range #6 - 250 Kcmil (Single - Phase, Qty. 3), #2 - 600 Kcmil (Three - Phase, Qty. 22), Hardware, Bolt Size 1/4 - 20 X 3/4 (Single - Phase, Qty.3), 3/8 - 16 X 2 (Three - Phase, Qty. 16) | Terminal Lug Kit | 1.1" | €1,300.37 | |
| D | LKS1 | Terminal Lugs, Cable Range #14 - #2 (Single - Phase, Qty. 8), #6 - 250 Kcmil (Three - Phase, Qty. 4), Hardware, Bolt Size 1/4 - 20 X 3/4 (Qty. 8) | Terminal Lug Kit | 1.1" | €158.93 |
Frequently Asked Questions
How to install the terminal lugs on Eaton dry-type distribution transformers?
- Turn off the power to the transformer before installing the lugs.
- Open the enclosure of the transformer and locate the terminals.
- Verify the size and configuration of the terminal lug. Ensure that it matches the transformer terminals.
- Remove any existing cables or wires from the terminals and clean the surface.
- Install the terminal lugs onto the cables or wires, following the instructions given in the manual.
- Tighten the terminal nut to the torque specified in the instructions.
- Ensure that the electrical connections are secure and that there are no loose or exposed wires.
- Close the transformer enclosure and turn on the power.
- Test the transformer to check that it is functioning properly.
What are the terminal lugs made of?
The lugs are composed of high-quality materials, such as aluminium & copper, which provide excellent conductivity and corrosion resistance.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
- Portable Carbon Monoxide Detector
- Battery Powered Hydraulic Pump
- Spark Proof Centrifugal Blower
- Breathing Air Cascade System
- Forklift Fuses
- Excess Flow Valve
- Thermal Expansion Valve
- Venturi Style Pneumatic Air Blower
- Lay Flat Plastic Ducting
- Curved Jaw Coupling
- Hydronic Manometer Kit
- Solenoid Valve Coils
Explore More
- ALBION CASTERS
- KEYSHAFT
- KH INDUSTRIES
- TRIMACO
- ZIPLINK
- Security Seals
- Sillcocks
- Insulator Washers
- Filter Heads
- Vortex Coolers
- AKRO-MILS 35195 Nest And Stack Totes
- HELICOIL High Spiral Flute Bottoming Taps, UNC, 3B
- ANSELL 93-700 Touchntuff Sterile Nitrile Disposable Gloves
- MILLER BY HONEYWELL Double D-Ring Body Belts, Without Pad
- ACME ELECTRIC Three Phase Dry Type Distribution Transformers, 208V Delta Primary Volts, 480Y/277 Secondary Volts
- WEARWELL 560 Series, Mat Ramp
- GATES Standard V-Belts, C Section
- DESTACO 624 Series Straight Line Action Clamps
- MI-T-M Voltage Converters
- DYNABRADE Sanding Pads