EATON CH Series High Magnetic Circuit Breakers
Eaton CH Series high magnetic circuit breakers are designed to fit in standard load centres & panel boards and protect against overloads and short circuits. They feature a high magnetic trip element that offers superior protection against high inrush current, with an interrupting capacity o...f up to 10kA. They feature a compact design that allows easy installation and maintenance, making these breakers ideal for applications, such as HVAC, pumps, compressors and other motor loads. These breakers can also be used with a wide range of accessories, including shunt trips, auxiliary contacts and undervoltage releases.Read more
| Style | Model | Circuit Breaker Type | Number Of Poles | Voltage | Price | |
|---|---|---|---|---|---|---|
| A | CH215HM | CH | 2 | 120/240V | €97.12 | |
| A | CH220HM | CH | 2 | 120/240V | €113.12 |
Working Mechanism
- When the current flowing through the circuit breaker exceeds the maximum allowable value, the magnetic element generates a magnetic field, causing the breaker to trip (or open the circuit).
- This phenomenon interrupts the flow of current and prevents damage to the electric system.
- Additionally, they have a bi-metallic strip which responds to the heat generated by the current flowing through the breaker.
- This element can also trip the breaker if the current exceeds the rated value, protecting against overload.
Frequently Asked Questions
What is the use of a manual trip?
The CH Series circuit breakers come with a manual trip that allows the operator to manually open the circuit in case of emergency or power failure.
What is the purpose of a loadcentre?
A loadcentre is a distribution panel that houses and manages the distribution of electrical power in a building or other facilities. It includes a main breaker that acts as the primary protection for the entire electrical system, as well as several individual circuit breakers that protect the system from potential damage from short circuits or overload occurrences.
How can I reset a tripped circuit breaker?
- For resetting manually, locate the breaker panel and then the breaker that has tripped.
- Switch the breaker to the OFF position, then back to the ON position.
- The user can use a toggle provided on the breaker to reset the tripped unit.
We are here to help!
Looking for a part not listed here?
Explore More
- AIR SYSTEMS INTERNATIONAL
- KEYSHAFT
- STREN-FLEX
- W F HARRIS LIGHTING
- HANDLE-IT
- Lighting Photocontrols
- High Head Effluent Pumps
- Belt Drive Blower Accessories
- Tapping Heads
- Diggers Paving Breakers and Jackhammers
- PS DOORS Safemezz Vertical Gates
- ANSELL 80-100 Activarmr Natural Rubber Latex Coated Gloves
- CHICAGO PROTECTIVE APPAREL CarbonX Pants Black
- CONDOR Cowhide Leather Gray Palm Gloves
- KEO Woodruff Keyseat Cutter Sets
- CHRONOMITE LABS Electric Tankless Water Heaters
- MITEE-BITE PRODUCTS INC T-Slot Toe Clamp
- VERMONT GAGE Go/NoGo Standard Thread Plug Gages, 1 3/8-6 Unc Lh
- GERMGUARDIAN Replacement Filters
- TE-CO Step Blocks