EATON CH Series Arc Fault/ Ground Fault Circuit Breakers
Eaton CH Series arc fault / ground fault circuit breakers are ideal for protecting electrical systems from damage caused due to arc faults & ground faults. These circuit breakers are UL-listed and can detect & respond to various electrical conditions to prevent fires. They have a single... pole configuration and an interrupt rating of 10kAIC.Read more
Filter
| Style | Model | Height | Amps | Wire Size | No. Of Poles | Interrupt Rating | Features | Depth | Phase | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | CHFAFGF115 | 1 1/4" | 15A | - | 1 | 10 kAIC | - | - | - | €164.41 | |
| B | CHFP120DF | 1 1/5" | 20A | - | 1 | 10 kAIC | Plug-On Neutral | 3.25" | 1 | €89.80 | |
| B | CHFP115DF | 1 1/5" | 15A | - | 1 | 10 kAIC | Plug-On Neutral | - | - | €89.80 | |
| A | CHFAFGF115CS | 3/4" | 15A | #14 AWG | 1 | 10 kAIC | - | - | - | €651.26 | |
| C | CHFAFGF115PN | 3/4" | 15A | - | 1 | 10 kAIC | Plug-On Neutral | - | - | €164.41 | |
| D | CHFAFGF120 | 3/4" | 20A | - | 1 | 10 kAIC | - | - | - | €121.42 | |
| E | CHFAFGF120PN | 3/4" | 20A | - | 1 | 10 kAIC | Plug-On Neutral | - | - | €164.41 | |
| D | CHFAFGF120CS | 3/4" | 20A | 12 AWG | 1 | 10 kAIC | - | - | - | €651.26 |
Working Mechanism
- Eaton CH Series arc fault / ground fault circuit breakers constantly monitor the electrical current flowing through the circuit.
- Arc fault circuit breakers detect dangerous arcing conditions by monitoring the current flowing through the circuit and looking for patterns that can indicate arcing. Ground fault circuit breakers, on the other hand, detect dangerous ground faults that can occur when electrical current flows through an unintended path to the ground by comparing the current flowing out of the circuit with the current returning to the circuit.
- When an abnormal condition is detected, the circuit breaker quickly interrupts the flow of electricity to the circuit, shutting off power to the affected area, preventing potential damage to the connected equipment.
Frequently Asked Questions
What is the current rating of these Eaton CH Series arc fault / ground fault circuit breakers?
15 & 20
Can these circuit breakers be installed directly on loadcenters?
Selected Eaton CH Series arc fault / ground fault circuit breakers have a plug-on neutral feature for allowing them to connect directly to the neutral bar of a loadcenter without wiring a pigtail.
What are the operating conditions of these Eaton CH Series arc fault / ground fault circuit breakers?
They can operate at temperatures ranging from -31 to 150 degrees F (-35 to +66 degrees C) and non-condensing humidity ranging from 0 to 95%.
We are here to help!
Looking for a part not listed here?
Explore More
- DYNABRADE
- KEYSHAFT
- BETA TOOLS
- KERN AND SOHN
- PETERSEN PRODUCTS
- Die Sets
- LED Road Flares, Safety Lights
- Counters
- Door Switches
- Floor Box Covers
- ANSELL 27-607 Activarmr Heavy Duty Nitrile Coated Safety Gloves
- ANSELL 87-224 Alphatec Neoprene Natura Latex Chemical Resistant Gloves
- CONDOR Coated Gloves, Smooth, Polyurethane, Palm Dipped, Black
- LUMAPRO Hand Lamp Cord Reels
- MUELLER INDUSTRIES 781SS-WE Y Strainers
- WERA TOOLS Flex Socket Extension
- GREENLEE Kits
- APPROVED VENDOR M3 x 0.5 Fully Threaded Standard Slotted Pan PTFE Plastic Rounded Machine Screws
- SAFE FLEX Kits
- PLAST-O-MATIC EBVF1-5 Series Electrically Actuated Ball Valves, CPVC