EATON CH AFCI Series Circuit Breakers
Eaton CH AFCI circuit breakers detect the characteristic patterns of arcing fault current and trip or shut off the electrical circuit to prevent potential fire hazards. These circuit breakers are available in single-pole and two-pole configurations.
| Style | Model | No. Of Poles | Amps | Height | Features | Voltage | Interrupt Rating | For Use With | Main Circuit Breaker | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | CHFCAF115CS | 1 | 15A | 3" | Clamshell Pack | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €554.20 | |
| A | CHFCAF115 | 1 | 15A | - | - | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €149.29 | |
| A | CHFCAF120CS | 1 | 20A | 3" | Clamshell Pack | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €554.20 | |
| A | CHFCAF115PN | 1 | 15A | 3" | - | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €120.85 | |
| A | CHFCAF120PN | 1 | 20A | - | - | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €120.85 | |
| A | CHFCAF120 | 1 | 20A | 1 1/4" | - | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €149.29 | |
| B | CHFP115AF | 1 | 15A | 1 1/5" | Plug-On Neutral | - | 10 kAIC | Type CH Loadcenters | - | €76.93 | |
| C | CH215CAF | 2 | 15A | 2 2/5" | Combination Arc Fault | 120/240V | 10 kAIC | Type CH Loadcenters | CH | - | RFQ
|
| D | CH215AF | 2 | 15A | 2 1/2" | - | 120/240V | 10 kAIC | Type CH Loadcenters | CH | - | RFQ
|
| C | CH220CAF | 2 | 20A | 2 1/2" | Combination Arc Fault | 120/240V | 10 kAIC | Type CH Loadcenters | CH | €563.75 | |
| E | CH220AF | 2 | 20A | - | - | 120/240V | 10 kAIC | - | - | - | RFQ
|
Working Mechanism
- Eaton AFCI circuit breakers utilise sensors to monitor the electrical current flowing through the circuit.
- When the circuit breaker detects an arc fault, it interrupts the flow of electricity to prevent fire risks.
Features
- Eaton CH AFCI circuit breakers have an LED to indicate one of the seven trip codes to simplify circuit diagnostics.
- These circuit breakers provide branch overvoltage protection for sensitive electronics and have an interrupt rating of 10kIAC.
- Their thermal-magnetic trip curve avoids nuisance tripping on mild overloads but reacts almost instantaneously to severe short-circuit conditions.
- Selected models have trip flags to differentiate between a 'trip' and the 'breaker being turned off' conditions.
Compatible Accessories
- Eaton CH Loadcenters: These units are suitable to contain these CH circuit breakers and come in options for surface-mounted, flush-mounted and combination settings.
Standards and Approvals
- UL
- NEC
Frequently Asked Questions
What is the difference between an AFCI and GFCI?
GFCI protects people from electric shocks due to a ground fault, whereas the AFCI protects the branch circuit wiring from dangerous arcing faults.
What is an arc fault?
Arc fault is an unintended arc created by current flowing through an unplanned path. Arcing creates high-intensity heating that results in burning particles that may easily ignite surrounding material, such as wood framing or insulation.
Can AFCI circuit breakers be reset?
Yes, AFCI circuit breakers can be reset after they trip or shut off due to an arc fault.
Can AFCI circuit breakers be used with surge protectors?
Yes, AFCI circuit breakers can be used with surge protectors.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- FRIO-TEMP
- HERKULES
- KEYSHAFT
- NEX FLOW
- TITAN
- Class G Fuses
- Lug Nut Wrenches
- Copper Foil Rolls
- Receptacle and GFCI Tester Accessories
- Shank Mount Surface Conditioning Sanding Discs
- HELICOIL Spiral Point Plug Taps, UNF, 2B
- CONDOR Coated Gloves, Smooth, Nitrile
- ANSELL 47-402 Activarmr Comfortable Oil Repellent Gloves For Medium Duty Tasks
- JOHN GUEST Plugs, Polypropylene White
- GLOBE SCIENTIFIC Globe Glass Volumetric Flasks
- DAYTON Rigid Shaft Couplings
- WALTER TOOLS Jobber Drill 7.5mm Carbide
- THOMAS & BETTS 54282 Series Lug Compression Connectors
- JOHNSON CONTROLS V-4440 Series Water Valves
- BRISKHEAT Radome Series Curing Heating Blankets