EATON Bussmann Series CLS Fuses
Eaton Bussmann Series CLS fuses are current-limiting fuses ideal for energy-limiting fault protection in indoor distribution systems. They offer effective control of fault magnitude & fault duration. These R-rated current limiting fuses operate quietly without any discharge, ensuring safety... in the connected system. Selected models have an interrupt rating of 50kA.Read more
| Style | Model | Amps | Height | Interrupt Rating | Fuse Class | Price | |
|---|---|---|---|---|---|---|---|
| A | 8CLS-4R | - | - | - | - | €2,632.05 | |
| B | 2CLS-25 | 25A | 3" | 50 Kaic | - | €2,158.36 | |
| A | 8CLS-30 | 30A | 3" | 50 Kaic | - | €2,708.46 | |
| C | 5CLS-30 | 30A | 3" | 50 Kaic | - | €2,062.86 | |
| A | 8CLS-60 | 60A | 3" | 50 Kaic | - | €2,777.23 | |
| C | 5CLS-2R | 70A | 3" | 50 Kaic | Class R | €2,391.38 | |
| A | 8CLS-70 | 70A | 3" | 50 Kaic | - | €3,006.43 | |
| B | 2CLS-2R | 70A | 3" | 50 Kaic | Class R | €2,158.36 | |
| B | 2CLS-3R | 100A | 3" | 50 Kaic | Class R | €2,353.19 | |
| C | 5CLS-3R | 100A | 3" | 50 Kaic | Class R | €2,391.38 | |
| C | 5CLS-4R | 130A | 3" | 50 Kaic | Class R | €2,391.38 | |
| B | 2CLS-4R | 130A | 3" | 50 Kaic | Class R | €2,532.74 | |
| C | 5CLS-5R | 150A | 3" | 50 Kaic | Class R | €3,373.17 | |
| B | 2CLS-5R | 150A | 3" | 50 Kaic | Class R | €3,300.58 | |
| C | 5CLS-6R | 170A | 3" | 50 Kaic | Class R | €4,225.04 | |
| B | 2CLS-6R | 170A | 3" | 50 Kaic | Class R | €4,152.48 | |
| A | 5CLS-9R | 200A | 3" | 50 Kaic | Class R | €4,225.04 | |
| B | 2CLS-200 | 200A | - | - | - | €4,377.86 | |
| B | 2CLS-230 | 230A | 0.001" | - | - | €4,481.00 | |
| A | 5CLS-12R | 230A | 3" | 50 Kaic | Class R | €4,626.17 | |
| D | 2CLS-390 | 390A | 0.001" | - | - | €6,876.20 | |
| C | 5CLS-18R | 390A | 3" | 50 Kaic | Class R | €6,795.99 | |
| C | 5CLS-24R | 450A | 3" | 50 Kaic | Class R | €6,795.99 | |
| D | 2CLS-24R | 450A | 3" | 50 Kaic | Class R | €7,292.60 |
Working Mechanism
- When these Eaton Bussmann Series CLS fuses face high fault currents, their fuse element melts instantly to lose the energy in the surrounding sand.
- The sand melts to form fulgurite, a glass-like substance and increases the arc voltage to approximately twice the system voltage, subsequently forcing the current to zero.
- When these fuses face a low fault, the incoming current melts a solder drop on the silver fuse element.
- The element burns back till a sufficient gap is established to interrupt the current. This process is commonly known as the M-effect.
Frequently Asked Questions
What are these Eaton Bussmann Series CLS fuses made of?
These precision-calibrated fuses have fiberglass-reinforced resin housing with copper-plated contact caps that are magneformed onto the housing for optimum strength. They are filled with high-purity silica sand & silver elements for efficient protection. A durable label is located on each fuse to provide ratings & manufacturer information.
How are these Eaton Bussmann Series CLS fuses mounted?
Eaton current limiting fuses feature standard industry mounting sizes. Their mountings have either disconnect or non-disconnect designs. All Eaton current limiting fuses & mountings are easy to install and operate. These R-rated motor starter fuses feature an integral hookeye for connecting to AMPGARD switchgear or have a standard clip-style mounting for easy installation.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- SHARON PIPING
- OASE
- ACURITE
- BRENNAN INDUSTRIES
- Water Testing Meter Accessories
- Boltless Shelving
- Sponges and Scouring Pads
- Clamping Kits
- Diaphragm Compressor/Vacuum Pump
- AKRO-MILS 30287 Akrobins Super Size Bins
- LOUISVILLE FM1400HD Series Fiberglass Twin Front Ladders
- TEMPCO CRT Series E-Mitters
- KEO Woodruff Keyseat Cutter Sets
- ANVIL Forged Steel Crosses
- SPEARS VALVES CPVC True Union 2000 Standard Ball Valves, SR Threaded Ends, EPDM
- CLEVELAND General Purpose Spiral Point Taps
- GRAINGER Bonding And Grounding Wire And Accessories
- VIKAN 59 Inch Ultra Hygiene Handles