EATON Bulk Hoses


Eaton bulk hoses are used in water treatment plants and oil, gas & chemical industries to transfer large-volume fluids such as oils, gases, water, cement and abrasive materials over a long distance.

Filter
Safety Factor: 4:1 , Type: Hydraulic
StyleModelHose LengthReinforcementCover MaterialHose Outside Dia.Min. Bend RadiusOperating PressureDash SizeTemp. RangePrice (ex. VAT)
A
FC300-10-25
25ft.Single Wire BraidBlue Polyester Braid0.93"5-1/2"1750 psi10-55 To 302 F€826.14
A
FC300-05-25
25ft.Single Wire BraidBlue Polyester Braid0.58"3-3/8"3000 psi5-55 To 302 F€553.35
A
FC300-12-25
25ft.Single Wire BraidBlue Polyester Braid1.08"6-1/2"1500 psi12-55 To 302 F€779.28
A
FC300-16-25
25ft.Single Wire BraidBlue Polyester Braid1.27"7-3/8"800 PSI16-55 To 302 F€1,073.19
A
FC300-20-25
25ft.Single Wire BraidBlue Polyester Braid1.5"9"625 PSI20-55 To 302 F€1,318.28
B
GH793-4-50
50ft.2 Wire BraidSynthetic Rubber0.6"4"5800 PSI4-40 To 212 F€553.28
B
GH793-8-50
50ft.2 Wire BraidSynthetic Rubber0.87"7"4250 PSI8-40 To 212 F€713.87
B
GH793-10-50
50ft.2 Wire BraidSynthetic Rubber0.98"8"3625 PSI10-40 To 212 F€907.49
B
GH793-12-50
50ft.2 Wire BraidSynthetic Rubber1.16"9-1/2"3125 PSI12-40 To 212 F€1,139.24
B
GH793-16-50
50ft.2 Wire BraidSynthetic Rubber1.5"12"2500 psi16-40 To 212 F€1,443.86

Features

  • Eaton FC300 Series bulk hoses have polyethylene tubes for corrosion resistance on exposed surfaces. These bulk hoses can be operated at temperatures ranging from -55 to 212 degrees F. They are reinforced using polyester and wires for increased toughness and structural rigidity. These bulk hoses have blue polyester braided covers for durability and excellent abrasion resistance.
  • Eaton GH793 Series bulk hoses have synthetic rubber tubes for durability and resisting corrosion on exposed surfaces. These bulk hoses are reinforced with 2 wire braids to withstand high working pressures. They have operating temperatures ranging from -40 to 260 degrees F and come equipped with PVC / nitrile blend covers for leakproof operations.

Standards and Approvals

  • ABS
  • SAE J1402
  • SAE J1019
  • SAE 100R5
  • DNV
  • DOT FMVSS 106
  • USCG
  • MSHA
  • SAE 100R2AT Type S
  • EN853 2SN
  • ISO 1436-1 Type 2SN

Frequently Asked Questions

What is the maximum working pressure required for band clamp fittings in Eaton FC300 bulk hoses?

50 psi.

What is the operating pressure range of these bulk hoses?

625 to 5800 psi.

What is the significance of transfer tape in these hoses?

Transfer tapes are used as a lay line style in these bulk hoses to resist UV rays and high / low temperatures.

We are here to help!

Looking for a part not listed here?